[012] Local PGM Output Pulse Activation Time
[021] First Keypad Options
[022] Second Keypad Options
[023] Third Keypad Options
[030] Downloaded LCD Message
[031] Downloaded LCD Message Duration
[101]-[228] Door Chime for Zones 1-128
[991] Reset Keypad Programming to Factory Defaults
1. Press [*][8][Installer Code].
2. Enter [991].
3. Use the [<][>] keys to scroll to the applicable keypad.
4. Press [*] to select the keypad.
5. Re-enter [Installer Code].
6. Press [*] to reset the selected keypad to factory defaults.
I_____I_____I
Minutes (00-99)
I_____I_____I
Seconds (00-99)
Default
Opt.
ON
OFF
ON
I_____I
1
Fire Key Enabled
Fire Key Disabled
ON
I_____I
2
Medical Key Enabled
Medical Key Disabled
ON
I_____I
3
Panic Key Enabled
Panic Key Disabled
ON
I_____I
4
Display Access Code When Pro-
gramming
Display Xs When Program-
ming Access Codes
Default
Opt.
ON
OFF
ON
I_____I
1
Local Clock Display ON
Local Clock Display OFF
OFF
I_____I
2
Local Clock Displays 24-hr
Clock Displays AM/PM
ON
I_____I
3
Auto Alarm Mem Scroll ON
Auto Alarm Mem Scroll OFF
ON
I_____I
4
For Future Use
For Future Use
OFF
I_____I
5
Power LED Enabled
Power LED Disabled
ON
I_____I
6
Power LED Indicates AC Present ON Power LED Indicates AC Pres-
ent OFF
ON
I_____I
7
Alarms Displayed While Armed
Alarms Not Displayed While
Armed
OFF
I_____I
8
Auto-Scroll Open Zones ON
Auto-Scroll Open Zones OFF
Default
Opt.
ON
OFF
OFF
I____I
1
Armed LED Power Save
Armed LED Off in Sleep Mode
ON
I____I
2
Keypad Status Shows Stay Arm
Keypad Status Shows Stay/Away
Arm
OFF
I____I
3
5th Terminal is Keypad PGM Output 5th Terminal is Keypad Zone Input
OFF
I____I
7
Local Display of Temperature
No Local Display of Temperature
OFF
I____I
8
Low Temperature Warning
Enabled
Low Temperature Warning
Disabled
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____|
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____|
Default: 000
I
_____
I
_____
I
_____
I
(Valid entries are 000-255, 000=Unlimited Msg Display)
This number represents the number of times the downloaded message must be cleared before it is
permanently removed. This message can be cleared by pressing any key.
[041] Indoor Temperature Zone Assignment
Default: 000
I_____I_____I_____I
(Valid entries are 000-128)
[042] Outdoor Temperature Zone Assignment
Default: 000
I_____I_____I_____I
(Valid entries are 000-128)
The keypad can be programmed to make up to four different chime sounds for individual zones.
(e.g., for Zone 1, enter section [101], for Zone 2 enter section [102]).
Default: 01
I_I_I
Valid Entries
01
6 beeps
02
Bing-Bing tone
03
Ding-Dong tone
04
Alarm tone (4 second duration)
05
Zone name
Table 3: Keypad Display Symbols
1
Memory – Indicates that alarms are in mem-
ory.
10 Chime – Turns on when Door Chime is ena-
bled and off when Door Chime is disabled.
2
Fire – Indicates that fire alarms are in mem-
ory.
11 Away – Indicates that the panel is armed in
away mode.
3,4,
5
Clock Digits – These digits indicate the hour
and minutes when the local clock is active,
and also identify the zone when the OPEN or
ALARM icons are active. These digits scroll
one zone per second from the lowest zone
number to the highest when scrolling through
zones.
12 Stay – Indicates that the panel is armed in
stay mode.
13 Night – Indicates that the panel is armed in
night mode.
6
1 to 8 – These numbers display toggles or dig-
its in binary while they are needed.
14 Ready Light (green) – If the Ready light is
on, the system is ready for arming.
7
Bypass – Indicates that there are zones auto-
matically or manually bypassed.
15 Armed Light (red) – If the Armed light is
on, the system has been armed successfully.
8
Open – When zones are opened, this icon will
turn on and the open zones are displayed.
16 System Trouble – Indicates that a system
trouble is active.
9
Program – If the system is in Installer’s or
User’s Programming, or the keypad is busy,
this icon flashes. If an access code is required
while accessing star menus, this LED is on
steadily to indicate that the code is required.
17 AC – Indicates that AC is present at the
main panel.
1
2
7
8
9
12
10
3
11
13
4
5
6
14
15
16
17
Summary of Contents for HS2ICN
Page 38: ...NOTA...