2
Figure 1 - Parts
Identification of Parts
Table 1: Parts
Parts
1
Metal Casing
2
GSM Antenna
3
GSM Antenna Mounting Hardware
4
Anchor Screw Holes (3mm)
5
GSM Antenna Connector
6
SIM Card
7
Status LEDs (see page 5)
8
JP3 Current Limitation Jumper (refer to Ratings Section)
9
PC-Link Connector
10
Tamper Switch
11
Terminal Blocks
12
Battery Leads
13
Cable Entry
14
Earth Ground Wire
15
12V - 1.2Ah Battery
16
GSM Radio Module
17
SIM Card Holder
1
LE
LI
-
O1
M
O2 O3 O4 +OC AS
M L1 L2 L3 L4 +12V -
LOCK
OPEN
4
4
5
17
3
2
6
16
9
10
8
11
13
12
15
14
4
12 13
TAMPER
9
PGM3
8
PGM2
19 20
+
DC IN
-
11
AUX+
16
Z2
17
Z3
15
Z1
14
COM
10
PGM4
7
PGM1
6
COM
4
T1
5
R1
2
TIP
3
RNG
1
18
Z4
JP3
JP3
tie wrap
OFF ON
All circuits are classified for UL installations as Power Limited/Class II Power Limited except for the bat-
tery leads which are not power limited. Do not route any wiring over circuit boards. Maintain at least 1”
(25.4mm) separation. A minimum 1/4” (6.4mm) of separation must be maintained at all points between
Power Limited wiring and all other non-Power Limited wiring. Route wires as indicated above.
GS3060
NOTE:
For UL/ULC installa-
tions, connections between
the alarm control panel out-
puts (telephone interface
Tip/Ring, output relay con-
tacts) and GS3060 inputs
(Tip/Ring, Z1-Z4) shall be
run in a mechanical protec-
tive conduit within 20ft (6m)
of one another and in the
same room.
firealarmresources.com
Summary of Contents for GS3060