DSC GS3060 Installation Manual Download Page 5

1

The GS3060 is a wireless communicator that sends alarm system information to an SG-System III, SG-
System II, or SG-System I receiver through a GSM/GPRS wireless network. This wireless communicator can
be used with UL/ULC Listed compatible control units, as indicated in the manufacturer's installation
instructions.

NOTE: The GS3060 is designed to work with the Contact ID communication format as described in SIA DC-
05 Standard. Before completing the field installation of the alarm monitoring system please ensure com-
munication with the supervising central station is successful by sending several events and getting confir-
mation that they have been received.

Features

• Compatible with 4-digit or 10-digit Contact ID communication format as described in SIA DC-05

Standard. Example of suitable compatible alarm panels: DSC Models PC1864, PC1832, PC1616,
PC4020.

• Simulates landline
• Switches automatically to the GSM network in the event of landline trouble (e.g., line down)
• GSM Signal Indicator
• Four programmable outputs
• Contains one 12V - 1.2 Ah battery
• Case Tamper Output
• Landline overvoltage protection
• Dual-band GSM radio
• Four programmable inputs
• GPRS/Internet communication with Sur-Gard System III / II
• Panel transmission monitoring for up to four phone numbers

Technical Specifications

The input voltage to the GS3060 can be drawn from the UL/ULC Listed control panel or provided by an
external UL/ULC Listed power supply rated for the application (external power-limited source).

NOTE

: The power supply must be Class II, Power Limited. For residential applications a suitable power adap-

tor is model DSC ADP1310-NAU (for USA) and model DSC ADP1310-NA (for Canada).

Ratings

Power Supply Ratings - Input Voltage (for long-term operation)

JP3-OFF with internal battery: . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.8V

DC

required

JP3-ON without internal battery: . . . . . . . . . . . . . . . . . . . . . . . 13.8V

DC

recommended

NOTE: When the input voltage drops below 13.5V

DC

, the internal battery supplied with the GS3060

will not be charged. In order to maintain a charged level for the internal battery, the power supply
must have a minimum voltage of 13.5V

DC

to ensure a sufficient battery charge in all conditions of use.

Current Consumption

JP3-OFF with internal battery: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120mA*
JP3-ON without internal battery: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500mA*

* Plus any current drawn from the GS3060 AUX+ terminal

Working Voltage Range

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-14V

DC

Battery: . . . . . . . . sealed, rechargeable type, rated 12V/1.2Ah or 12VAh (for 24hr standby time)
Battery charging voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.5V

DC

Battery charging current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50mA

NOTE: Battery must be replaced every 3-5 years.

Operating frequency: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 850/1900MHz
Antenna gain: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0dBi

Environmental Specifications

Operating temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C-49°C (32°F-120°F)
Humidity: . . . . . . . . . . . . . . . . . . . . . . . . . . . 93%RH Maximum (non-condensing)

Mechanical Specifications

Dimensions (metal enclosure, painted): . . . . . . . . 138mm x 224mm x 55mm / 5.4” x 8.8” x 2.2”
Weight (without battery): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 900g / 3.2oz
Internal Event Buffer (communications): . . . . . . . . . . . . . . . . . . 256 Events (not viewable)

Simulated Telco Loop specifications (TIP/RING)

On-Hook Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35V

DC

Loop Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25mA
Loop Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 Ohms

Alternate construction

Dimensions (enclosure GS3060RF):

. . . . . . . . . . 165mm x 257mm x 76mm / 6.3” x 10.1” x 3”

Weight (alternate construction enclosure without battery):

. . . . . . . . . . . . . . 1300g / 2.8lbs

Introduction

firealarmresources.com

Summary of Contents for GS3060

Page 1: ...N MANUAL WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manu facturer The entire manual should be...

Page 2: ...firealarmresources com...

Page 3: ...4 Status LEDS 5 Operating Principles 6 Simulated Landline Mode 6 Panel Transmission Monitoring PTM 6 GPRS Sequence 6 Inputs 6 Outputs 7 Activating the Outputs 7 Swinger Shutdown 7 Hardware Default 7...

Page 4: ...attempt to service this product Opening or removing covers may expose the user to dangerous voltages or other risks Any servicing shall be referred to trained service personnel only Use authorized ac...

Page 5: ...rce NOTE The power supply must be Class II Power Limited For residential applications a suitable power adap tor is model DSC ADP1310 NAU for USA and model DSC ADP1310 NA for Canada Ratings Power Suppl...

Page 6: ...Z3 15 Z1 14 COM 10 PGM4 7 PGM1 6 COM 4 T1 5 R1 2 TIP 3 RNG 1 18 Z4 JP3 JP3 tie wrap OFF ON All circuits are classified for UL installations as Power Limited Class II Power Limited except for the bat...

Page 7: ...of communication supervision window of 200s required at monitoring station or as a back up when used in conjunction with a POTS line dialer The GS3060 shall be powered from any compatible listed contr...

Page 8: ...Power down the GS3060 by removing the DC power source and battery leads STEP 4 Connect the GS3060 1 Using the cabinet mark the four screw locations Drill the anchor screw holes NOTE Check for cable c...

Page 9: ...will switch on within three minutes in the event of GSM Module 16 trouble or when the GSM Network is unavailable No Service If this LED flashes the following list indicates the specific trouble based...

Page 10: ...e GS3060 performs this sequence on any phone number that is detected on the line Specific central station phone numbers can be programmed into the GS3060 if desired Up to four 20 digit numbers can be...

Page 11: ...ill not restore its state until all the causes of activation are cleared Contact ID Events Description Event Codes INPUT 1 ACTIVATION E110 FIRE ZONE 001 991 INPUT 1 RESTORAL R110 FIRE ZONE 001 991 INP...

Page 12: ...60 transmits a signal for the control panel or for an internal transmission the YELLOW light will flash one time when the signal is transmitted and two times when it gets a kiss off SIM the SIM should...

Page 13: ...8VDC 120mA minimum Ensure the GS3060 jumper J3 is OFF Two Flashes SIM Radio Trouble Ensure the SIM Card is inserted correctly and firmly Ensure the antenna cable is plugged securely into the radio co...

Page 14: ...has the correct account num ber programmed Verify the reporting codes are programmed or the auto Contact ID option is enabled Ensure the control panel communicator is enabled Connect a handset to T1 a...

Page 15: ...can also be checked through the GVRU New Features for V3 16 Critical Shutdown on GS3060 backup battery If the GS3060 backup battery is used and is below 10 5VDC the unit will go into critical shutdow...

Page 16: ...iring and ensure connections are correct before turning on Connect relay contacts to a zone input on the alarm control panel for GS3060 troubles supervision 24hr type zone Optional use of PGM output S...

Page 17: ...8 6 19 Z4 Z3 Z2 COM 20 Z1 12 AUX PGM 3 PGM 1 13 PGM 4 COM TAMPER GS3060 PGM 3 DC IN KSAD1380100W1US Power Adaptor NOTES 1 Program the Zone Point as Supervisory type with keypad only annunciation when...

Page 18: ...Fire Supervisory Trouble DSC Subscribers Unit Fire Zone Inputs TIP TIP RING PGM1 DSC Keypad LCD4501 PK55XX GSM Transmitter GS3055 I GS3060 T1 R1 TIP RING Zone Input PGM4 AUX Power 12V 700mA RM1C ULC...

Page 19: ...d LCD4501 PK55XX GSM Transmitter GS3055 I GS3060 T1 R1 PGM1 TIP RING Zone Input PGM4 AUX Power 12V 700mA RM1C ULC Relay PC5003C PC4050CR cabinet GSM Network GPRS IP Data PSTN AC Input AC Input PC4020...

Page 20: ...ails for GSM Supervision Relay Redundant Fire Alarm Transmission NOTE Use EOL resistor in series with N O contacts of the relay connected to PGM4 5 6 KOhm GSM Supervision Relay Redundant Fire Alarm In...

Page 21: ...Supervision Relay and Redundant Fire Alarm Transmission NOTE Use EOL resistor in series with N O contacts of the relay connected to PGM4 DG009071 19 20 DC IN 5 6 KOhm 5 6 KOhm GSM Supervision Relay P...

Page 22: ...terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other rights DSC may termi nat...

Page 23: ...uninterrupted service Equipment Maintenance Facility If trouble is experienced with this equipment for repair or warranty information please contact the facility indicated below If the equipment is ca...

Page 24: ...other abuse mishandling or improper application of the products Items Not Covered by Warranty In addition to the items which void the Warranty the following items shall not be covered by Warranty i fr...

Reviews: