8
GS3050-A
- GSM Dialler and Interface
Table 3 - TERMINALS
1-2 [L.E.]
External telephone line
.These terminals can be connected to the PSTN line.
3-4 [L.I.]
Internal telephone line
. These terminals (normally connected to the PSTN line) must
be connected to the telephone device terminals (terminals L.E. on Bentel Diallers).
5 [
-
-
-
-
]
Earth
. In compliance with the Telecommunications Network Safety Standards
(Overvoltage protection), this terminal must be connected to the Mains Earth.
6-14 [
M
M
M
M
]
Negative
Power Supply
7-8-9-10-11
[01]...[05]
Programmable Open-Collector Outputs
that can be activated by SMS or the
following events:
1) PSTN Trouble (
O1
at default)
2) GSM Trouble (
O2
at default)
3) COMMUNICATION Trouble between the MAIN Board and GSM Module (
O3
at default)
5) OUTGOING call (
O5
at default)
5) INCOMING call (
O5
at default)
12-13 [A.S.]
Tamper
. These terminals must be connected to the Tamper switch: they are closed when
the GS3050-A is properly closed, and will open when the frontplate is removed.
15-16-17-18
[L1]...[L4]
Programmable Alarm line
. Activates the SMS Dialler and Telephone functions (Line
1 [
L1
] priority)
19-20
[+ 12V][–]
Power Supply
. These terminals must be connected to a 13.8 V
_
_
_
_
1A min. power
supply, whereas.
The GS3050-A must be connected to a standby battery.
Table 2 - INPUT POLARITY
Activation
Command for
Input Lines
Settings
Jumper
P2 - P3*
Programming
Via Software
Manual
Positive
+12V
a
O
O
O
O
O
O
O
O
o
o
o
o
á
á
á
á
N.C.
LLLL
Positive
Floating/GND 0V
a
O
O
O
O
O
O
O
O
o
o
o
o
â
â
â
â
N.O.
HHHH
Negative
GND 0V
b
o
o
o
o
O
O
O
O
O
O
O
O
â
â
â
â
N.O.
HHHH
Negative
Floating/12V
b
o
o
o
o
O
O
O
O
O
O
O
O
á
á
á
á
N.C.
LLLL
(*) - The Jumper P2 (17) sets the polarity of Lines L1 and L2.
(*) - The Jumper P3 (18) isets the polarity of Lines L3 and L4.
G
G
G
G
G
Test the GSM Network signal strength
before mounting the GS3050-A in the
proposed placement.
1
. Remove the screws and the metal casing [
1
].
2
. Drill the anchor screw holes (use the back-
plate to mark the screw locations).
G
Check for cable conduits and water
pipes before drilling.
3
. Lay the cables, then pull them through the ca-
ble entry [
11
].
4
. Attach the backplate to the wall.
5
. Insert the SIM-CARD (see Figure 2a).
G
The SIM-CARD PIN must be disabled.
6.
Complete the connections on the terminal bo-
ard [10].
7
. Fit the antenna [
2
] and connector [
5
], then clo-
se the
GS3050-A
.
CONNECTIONS
A detailed description of the
GS3050-A
terminals
can be found in Table 3.
G
G
G
G
G
Use shielded cable only for all
connections, with one end connected to
negative, and the other floating.
Connect the Security device telephone terminals
(
L.E.
on BENTEL products) to terminals 3-4 (
L.I.
)
on the
GS3050-A
board and, if required, connect
Terminals 1-2 (
L.E.
) directly to the PSTN line.
The 5 OC Outputs refer respectively to terminals 7-
8-9-10 and 11 (
O1
,
O2
,
O3
,
O4
and
O5
). These
Outputs are programmed at default to signal the even-
ts shown in Table 3. The Output signals and Standby
Polarity (
Normally Open
(
â
â
â
â
â
) or
Normally Closed
(
á
á
á
á
á
) can be programmed as per requirements.
Each OC Output can close 70 mA maximum
current to negative.