background image

2

Ratings

Power Supply Ratings

Input Voltage (Nominal):.  .  .  .  .  .  .  .  .  .  . 9-14V

DC

 (use separately listed control panel or power supply) or 

  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  13.8V

DC

 (use DSC ADP1320-NAx power adapter) 

Input Current: .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 500mA (9-14Vdc) or 700mA (13.8V

DC

Current Consumption

Average: .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   40mA*
Peak (no battery):  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 180mA*
Peak (with battery):  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 350mA*

* Plus any current drawn from the  terminal

Battery:   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  NiMH, rated 7.2V, 2.2Ah
Battery charging voltage (maximum):  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .9.1V

DC

Battery charging current:   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  60mA

NOTE: Battery must be replaced every 3-5 years.

Operating frequency:  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 850/1900MHz
Antenna gain: .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2.0dBi

Environmental Specifications

Operating temperature: .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  0°C-49°C (32°F-120°F)
Humidity:   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 93%RH Maximum (non-condensing)

Mechanical Specifications

Dimensions (plastic enclosure, painted): .  .  .  .   125 mm (W) × 220mm (H) × 31mm (D) / 4.9” × 8.7” × 1.2”
Weight (without battery):  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .400g / 1.2oz

Simulated Telco Loop specifications (TIP/RING)

On-Hook Voltage: .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 12V

DC

 

Off-Hook Voltage (maximum):   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .22V

DC

 

Loop Current   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  25mA
Loop Resistance  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .600 Ohms 
This equipment (3G4000) is fixed and shall be installed by Service Persons only (Service Person is defined as 
a person having the appropriate technical training and experience necessary to be aware of hazards to 
which that person may be exposed in performing a task, and of measures available to minimize the risks to 
that person or other persons). It shall be installed and used within an environment that provides the 
pollution degree max 2, over voltages category II, in non-hazardous, indoor locations only. This manual shall 
be used with the Installation Manual of the relevant alarm control panel. All instructions specified within that 
manual must be observed.

Installing the 3G4000

C24 Communications Enrolment

The 3G4000 requires enrolment with C24 Communications to operate. For more information, please visit 
www.connect24.com, contact C24 Communications customer service at 1-888-251-7458 (US) / 1-888-955-
5583 (Canada) or contact the central station to inquire if they are a C24 Communications Master Reseller.

NOTES: Enrollment with C24 Communications should be performed before turning on the 3G4000 unit.

Before inserting or removing the SIM card, please ensure the unit is turned off.

STEP 1 - Initialize the 3G4000 with C24 Communications

The 3G4000 can be initialized with C24 Communications by:
web - www.connect24.com
mobile - m.connect24.com
To complete enrolment, a C24 profile, installer ID/PIN (or web credentials) and the 20-digit SIM number are 
required.

NOTE: The SIM activation process with the cellular carrier typically takes between five and ten minutes 
to complete.

STEP 2 - Determine the Best Signal Location

1. Remove the front cover by inserting a screwdriver into each of the slots at the bottom of the enclosure 

and pushing down.

2. Apply power (DC and/or battery). The 3G4000 is now in placement test mode.

STEP 2a – SIM card is activated.

The red LED will be on solid, the blue LED will be off and the signal strength LEDs will display the average 
signal strength. In this state, the 3G4000 is registered to the cellular network.

 

Summary of Contents for 3g4000

Page 1: ...NING This manual contains information on limitations regarding prod uct use and function and information on the limitations as to liability of the man ufacturer The entire manual should be carefully r...

Page 2: ...ees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other rights DSC ma...

Page 3: ...tion instructions NOTE The 3G4000 is designed to work with the Contact ID communication format as described in SIA DC 05 Standard Before completing the field installation of the alarm monitoring syste...

Page 4: ...category II in non hazardous indoor locations only This manual shall be used with the Installation Manual of the relevant alarm control panel All instructions specified within that manual must be obse...

Page 5: ...the blue LED indicates that the 3G4000 has requested programming from C24 Communications and is waiting for a response Once remote programming is completed the blue LED will switch to solid and the 3G...

Page 6: ...hall be rated LPS power limited Use only power supplies that have AUX output isolated from EGND Typical battery charge 30 50 mA Recommended Model NiMH Rated 7 2V 2 2Ah Use only Model 6PH H AA2200 S D2...

Page 7: ...roduct It is designed to be connected to a compatible modular jack that is also compliant See installation instructions for details Ringer Equivalence Number REN The REN is used to determine the numbe...

Page 8: ...arising out of any other abuse mishandling or improper application of the products Items Not Covered by Warranty In addition to the items which void the Warranty the following items shall not be cove...

Reviews: