IMPORTANT

The equipment is fixed, wall-mounted and shall be installed in the position specified in these 
instructions. The equipment enclosure must be fully assembled and closed, with all the neces-
sary screws/tabs and secured to a wall before operation. Internal wiring must be routed in a 
manner that prevents:
- Excessive strain on wire and on terminal connections
- Loosening of terminal; connections
- Damage of conductor insulation

WARNING

Never install this equipment during a lightning storm!

Instruct the end-user to:
- Not attempt to service this product. Opening or removing covers may expose the user to dan-

gerous voltages or other risks. Any servicing shall be referred to trained service persons only.

- Use authorized accessories only with this equipment.
Do not dispose of the battery in fire or water. Disposing of the battery in a fire will cause rupture 
and explosion.
Do not dispose of the waste battery as unsorted municipal waste. Consult your local regulations 
and /or laws regarding recycling with regard to this NiMH battery pack. Doing so will help protect 
the environment. Some of the materials that are found within the battery could become toxic if 
not disposed of properly and may affect the environment

.

Introduction

The 3G4000 is a wireless communicator that sends alarm system information to a Sur-Gard SG-System I-IP, II, 
III, IV or 5 Receiver through a 3G (HSPA) or 2G (GPRS) wireless network. This wireless communicator can be 
used with UL/ULC Listed compatible control units, as indicated in the manufacturer's installation instructions.

NOTE: 

The 3G4000 is designed to work with the Contact ID communication format as described in SIA DC-

05 Standard. Before completing the field installation of the alarm monitoring system, please ensure com-
munication with the supervising central station is successful by sending several events and getting confir-
mation that they have been received.

Features

• Compatible with 4-digit or 10-digit Contact ID communication format as described in SIA DC-05 

Standard. Example of suitable compatible alarm panels: DSC Models PC1864, PC1832, PC1616, 
PC4020.

• Simulates landline
• Switches automatically to the 3G (HSPA) or 2G (GPRS) network in the event of landline trouble (e.g., 

line down)

• Phone Number Call Direction
• SMS Command and Control
• Bi-Color Wireless Signal Indicator
• Two programmable outputs
• Case and Wall Tamper
• Landline overvoltage protection
• Dual-band UMTS/HSPA; Quad-Band GSM/EDGE Radio
• Two programmable inputs
• 3G (HSPA)/2G (GPRS) / Internet communication with Sur-Gard SG-System I-IP / II / III / IV / 5
• Panel transmission monitoring for up to four phone numbers
• Remote firmware upgrade
• DLS support for status, firmware updates
• Advanced Carrier Selection
• Remote Debug Enable
• Easy enrolment with C24 Communications via VRU, web or mobile interface

Technical Specifications

The input voltage to the 3G4000 can be drawn from the UL/ULC Listed control panel or provided by an 
external UL/ULC Listed power supply (with battery back-up) rated for the application (external power-limited 
source).

NOTES: 

The power supply must be Class 2, Power Limited. A suitable power adaptor is model DSC ADP1320-

NAU (for USA) and model DSC ADP1320-NA (for Canada).

For UL/ULC listed installations the input rating for the external power adapter is 120V

AC

/60Hz/0.4A.

Summary of Contents for 3g4000

Page 1: ...NING This manual contains information on limitations regarding prod uct use and function and information on the limitations as to liability of the man ufacturer The entire manual should be carefully r...

Page 2: ...ees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other rights DSC ma...

Page 3: ...tion instructions NOTE The 3G4000 is designed to work with the Contact ID communication format as described in SIA DC 05 Standard Before completing the field installation of the alarm monitoring syste...

Page 4: ...category II in non hazardous indoor locations only This manual shall be used with the Installation Manual of the relevant alarm control panel All instructions specified within that manual must be obse...

Page 5: ...the blue LED indicates that the 3G4000 has requested programming from C24 Communications and is waiting for a response Once remote programming is completed the blue LED will switch to solid and the 3G...

Page 6: ...hall be rated LPS power limited Use only power supplies that have AUX output isolated from EGND Typical battery charge 30 50 mA Recommended Model NiMH Rated 7 2V 2 2Ah Use only Model 6PH H AA2200 S D2...

Page 7: ...roduct It is designed to be connected to a compatible modular jack that is also compliant See installation instructions for details Ringer Equivalence Number REN The REN is used to determine the numbe...

Page 8: ...arising out of any other abuse mishandling or improper application of the products Items Not Covered by Warranty In addition to the items which void the Warranty the following items shall not be cove...

Reviews: