Location

Ideally, locate one keypad close to the primary entry/exit
door of the premises within 305 m (1000 ft.) of the control
panel. Do not mount the keypad outdoors (See 

Section 8.0

Commercial Fire Applications

).

4.0

Mounting

Mount the keypad no higher than shoulder height of the
shortest person using the system.

1. Remove the keypad’s cover.

2. Insert a small flat-head screwdriver in each slot at the

bottom of the base. Press up, and pull the cover off.

* Installer's Mode Address Setting:

 Use for direct connection

of Installer's Keypad.

Address Jumpers

Module

Address

1

2

4

8

16

MODE

0*

OFF

OFF

OFF

OFF

OFF

OFF

1

ON

OFF

OFF

OFF

OFF

ON

2

OFF

ON

OFF

OFF

OFF

ON

3

ON

ON

OFF

OFF

OFF

ON

4

OFF

OFF

ON

OFF

OFF

ON

5

ON

OFF

ON

OFF

OFF

ON

6

OFF

ON

ON

OFF

OFF

ON

7

ON

ON

ON

OFF

OFF

ON

8

OFF

OFF

OFF

ON

OFF

ON

9

ON

OFF

OFF

ON

OFF

ON

10

OFF

ON

OFF

ON

OFF

ON

11

ON

ON

OFF

ON

OFF

ON

12

OFF

OFF

ON

ON

OFF

ON

13

ON

OFF

ON

ON

OFF

ON

14

OFF

ON

ON

ON

OFF

ON

15

ON

ON

ON

ON

OFF

ON

16

OFF

OFF

OFF

OFF

ON

ON

17

ON

OFF

OFF

OFF

ON

ON

18

OFF

ON

OFF

OFF

ON

ON

19

ON

ON

OFF

OFF

ON

ON

20

OFF

OFF

ON

OFF

ON

ON

21

ON

OFF

ON

OFF

ON

ON

22

OFF

ON

ON

OFF

ON

ON

23

ON

ON

ON

OFF

ON

ON

24

OFF

OFF

OFF

ON

ON

ON

25

ON

OFF

OFF

ON

ON

ON

26

OFF

ON

OFF

ON

ON

ON

27

ON

ON

OFF

ON

ON

ON

28

OFF

OFF

ON

ON

ON

ON

29

ON

OFF

ON

ON

ON

ON

30

OFF

ON

ON

ON

ON

ON

31

ON

ON

ON

ON

ON

ON

32

OFF

OFF

OFF

OFF

OFF

ON

Table 4:

Keypad Address Selections for Other Control
Panels

4.1

Surface Mounting:

1. Use the base as a template and mark the location of the

mounting holes (use any holes).

2. Provide an opening in the mounting surface for the

wiring.

3. Pre-start the mounting screws but 

do not secure the

base at this time!

ADDRESS

1

2

4

8

16

MODE

1

2

3

4

5

Figure 4:

Internal View of DS7445i LED Keypad

1 - Address Jumper Pins

2 - Mode Pins

3 - Option  Bus  Terminals

4 - Access Relay Option Pins

5 - Sounder

1

1

2

3

4

5

Figure 3:

Back View of Keypad

1 - Double gang mounting holes

2 - Single gang mounting holes

3 - Terminal Strip opening

Do not use as wire entrance!

4 - Wire Entrance

5 - Sounder  Opening

4.2

Electrical Box Mounting:

-

See 

Figure 3

 to select the mounting holes, but 

do not

secure the base at this time!

"ON" indicates a shorting jumper across both pins

Module Addresses 15-32 are for use with the DS7200 Series
only.

Summary of Contents for DS7445i

Page 1: ...lace the shorting jumpers over the address pins as shown in Figure 2 Figure 2 shows proper shorting jumper placements Wire Gauge 18 AWG is required for UL Fire Installations Wire Type no shield 4 wire Max Resistance wire resistance should not exceed 33 ohms Table 1 Keypad Wiring Distances Maximum distance between control panel and each keypad should not exceed 305 m 1000 ft 1 Jumper Plug ON covers...

Page 2: ...OFF OFF ON ON 18 OFF ON OFF OFF ON ON 19 ON ON OFF OFF ON ON 20 OFF OFF ON OFF ON ON 21 ON OFF ON OFF ON ON 22 OFF ON ON OFF ON ON 23 ON ON ON OFF ON ON 24 OFF OFF OFF ON ON ON 25 ON OFF OFF ON ON ON 26 OFF ON OFF ON ON ON 27 ON ON OFF ON ON ON 28 OFF OFF ON ON ON ON 29 ON OFF ON ON ON ON 30 OFF ON ON ON ON ON 31 ON ON ON ON ON ON 32 OFF OFF OFF OFF OFF ON Table 4 Keypad Address Selections for Oth...

Page 3: ...base While feeding the excess wiring out of the rear of the base press the cover straight in until it latches 6 0 DS7447i DS7447E Contrast Control Turn the DS7447i DS7447E Keypad s contrast control clockwise to increase contrast Turn it counter clockwise to decrease contrast See Figure 5 for the location of the Contrast Control on the DS7447i DS7447E LCD Keypad 7 0 Special Key Labeling Do not labe...

Page 4: ...on of pull out slide Use Instruction Label P N 28815 if the keypad s you are installing are for use with the DS7060 DS7080i Series and DS7400Xi Series Control Panels Use Instruction Label P N 49646 if the keypad s you are installing are for use with the DS7200 Series Control Panels Keypad Notification Possible Causes DS7445i Continuous Sounder The yellow and green wires have been disconnected The ...

Reviews: