background image

Introduction

Thank you for purchasing the Nanoject II Control Box by Drummond Scientific Company.

This device can be used immediately after purchase. A summary of how to operate the

device is provided in this quick instruction manual.

Accessories available for purchase:

Replacement Glass 3.5˝ (vial of 100)  . . . . . . . . . . . . . . . . . . . . . . . .3-000-203-G/X

Replacement Glass 7˝ (vial of 100)  . . . . . . . . . . . . . . . . . . . . . . . . .3-000-203-G/XL

O-ring Kit with Collet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-000-002-KN

Wire Plunger (replacement)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-000-000-203-X

30G/2˝ Needle  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-000-027

Footswitch  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-000-032

(remote capability for fill, empty and inject functions)

Micromanipulator, MM33 (right hand)  . . . . . . . . . . . . . . . . . . . . . . . . . .3-000-024-R

(left hand)  . . . . . . . . . . . . . . . . . . . . . . . . . . .3-000-024-L

Support Base  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-000-025-SB

Magnetic Base  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-000-025-MB

Universal Adapter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-000-024-A

Part Number  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-000-029-D

Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100/240 volt, 50/60 Hz

Total Sample Volume  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2 nL

Fill Volume Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 nL or 46 nL/sec

Empty Volume Speed  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 nL/sec (only)

Injection Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 nL or 46 nL/sec

Volume Range  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3 nL - 69.0 nL

Plunger Travel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 mm 

Glass Micropipette Dimensions  . . . . . . . . . . . . . . . . . . . . . . OD 0.045˝ (1.14 mm)

I D 0.021˝ (0.53 mm) 

Control Box Dimensions

Weight:  . . . . . . . . . . . . . . . . . . . . . 0.43 kg

Length: . . . . . . . . . . . . . . . . . . . . . 14 cm

Width: . . . . . . . . . . . . . . . . . . . . . . 13.5 cm

Thickness:  . . . . . . . . . . . . . . . . . . 4 cm

Technical Specifications

3

Summary of Contents for Nanoject II

Page 1: ...Nanoject II Digital Control Box MADE IN USA INSTRUCTION MANUAL 3 000 029 D LABORATORY EQUIPMENT E21997...

Page 2: ...E ATTENTION TO THE RULES FOR SAFE OPERATION WARNINGS AND CAUTIONS Rules for Safe Operation Connections to Power Source Check the power source to see that the line voltage corresponds to the voltage in...

Page 3: ...le 3 000 027 Footswitch 3 000 032 remote capability for fill empty and inject functions Micromanipulator MM33 right hand 3 000 024 R left hand 3 000 024 L Support Base 3 000 025 SB Magnetic Base 3 000...

Page 4: ...filled with oil or other non compressible fluid before attachment to the injector Silicone or mineral oil is frequently used Backfilling is facilitated by using the 30 gauge x 2 needle and a syringe D...

Page 5: ...ing the FILL icon again The plunger is fully retracted to its preset home position when you hear an audible beep Viscous samples may require you to fill in small steps allowing the sample to equilibra...

Page 6: ...iple injections can be performed by simply pressing the INJECT icon again and again The injection rate is independent of the fill rate as programmed in the SETUP mode Press the EXIT icon to exit back...

Page 7: ...g the number of injection cycles Again use the and icons to select the value desired Pressing the BACK icon always returns you to the previously displayed screen Pressing the NEXT icon once again brin...

Page 8: ...ccur if plunger is not stopped at proper Home position Press the HOME icon to manually retract the plunger to the Home position Press the EXIT icon to exit back to the operational mode screen Below th...

Page 9: ...e In this mode the micropipette is manually filled or emptied Touch the MANUAL icon to go to the MANUAL MODE screen in the diagram below EMPTY Function When you touch this icon and the icon changes to...

Page 10: ...In this mode the FILL and EMPTY pedals are disabled Footswitch Operation INJECT Mode On the Operation screen select INJECT mode Enter the manual INJECT conditions VOLUME NL Displayed in ranges within...

Page 11: ...11 Notes...

Page 12: ...ev 0219 Printed in USA 500 Parkway Box 700 Broomall PA 19008 800 523 7480 FAX 610 353 6204 Website www drummondsci com For Technical Assistance call 1 800 523 7480 or e mail info drummondsci com Quest...