I nst allation manual
6 3
Malfunctions
Error code
F15 E09
F15 E04
F15 E99
F15 E04
F16 E21 E25
F17
F18 E30
LOST
BND
Problem
No connection between control (ESYS)
and gas control
APS malfunction
Error in wire connection
Fan PowerVent® does not start,
appliance does not spark
Fan PowerVent® does start,
appliance does not spark
Hardware Error controller (ESYS)
Hardware Error controller (ESYS)
Controller (ESYS) is not released
Communication loss between
transmitter and receiver (DFGT)
No communication between
remote control and receiver (DFGT)
Possible cause
Controller shot loose/mounted incorrectly
Controller mounted incorrectly
Pins on the connector on
the gas control are bent
APS bridge defective
Controller connected incorrectly
Fan is defective
Leaking differential pressure hoses
Differential pressure sensor defective
Control signal cable defective
Defect and/or leak in the concentric system
Controller defective
Controller defective
Controller is in hard lockout
Transmitter is out of the receiver's range
Obstacles between transmitter and receiver
Remote control and receiver
have not been coupled
Remote control defective
Remedy
Mount controller correctly
Mount controller correctly
Bend them straight
Place APS bridge on the controller
Connect the wiring of the
controller correctly
Replace the fan
Replace/repair connections and/or hoses
Replace differential pressure sensor
Replace the control signal cable
Check the concentric system for
leaks and defects. Repair if necessary
Replace controller
Replace controller
After 30 min. with mains voltage on
the appliance, F18/E30 can be reset
Bring the transmitter within the
range of the receiver
Remove obstacles between
transmitter and receiver
Couple the remote control
with the receiver
Replace remote control.
Summary of Contents for Maestro 60/2 Tall RCH
Page 15: ...Installation manual 15 A D B C 38C 2500 7 4...
Page 17: ...Installation manual 17 1 3 4 2 38C 2504 tooltip tooltip 7 6...
Page 19: ...Installation manual 19 38C 2793 1 2 3 4 5 6 7 7...
Page 21: ...Installation manual 21 1 3 2 4 38C 2619 586 5mm 1 2 38C 2503 7 8 7 9...
Page 23: ...Installation manual 23 5 7 8 6 38C 2507 1 60 1 3 2 4 2 mm 38C 2506 1 7 10 7 11...
Page 24: ...Installation manual 24...
Page 29: ...Installation manual 29...
Page 32: ...Installation manual 32...
Page 37: ...Installation manual 37 1 2 3 4 5 6 7 8 9 12 11 10 38C 2511 2 7 15...
Page 47: ...Installation manual 47 38P 0820 2 8 16...
Page 48: ...Installation manual 48 38P 0815 2 Eco Glow 38P 0814 2 Eco Glow 8 17 8 18...
Page 49: ...Installation manual 49 A C 38P 0816 2 B 8 19...
Page 50: ...Installation manual 50 D E 38P 0817 2 1 cm 8 20...
Page 51: ...Installation manual 51 38P 0819 0 Eco Glow F 38P 0818 0 G Eco Glow 8 21 8 22...
Page 52: ...Installation manual 52...
Page 57: ...Installation manual 57...
Page 64: ...Installation manual 64...
Page 65: ...Installation manual 65...
Page 66: ...Installation manual 66...
Page 67: ...Installation manual 67...