9.1 Igniting the appliance
Igniting the appliance takes place as follows: the appliance is switched on by means of an ignition command. This can be
done by means of the provided remote control, the DRU Fire App (iOS and Android) or a home automation system. The
receiver in the appliance gets the signal to start the ignition process. The valves in the gas control are switched on and a
reduced amount of gas flows to the main burner. The ignition mechanism sparks for 15 seconds, as a result of which the
main burner ignites.
In the case of a PowerVent® system, the module switches on after an ignition command, as a result of which the fan of the
system starts up. During starting up, a waiting time of 8 seconds applies. After this the appliance will ignite as described
above.
After ignition of the main burner (half the capacity), the ionization is measured to check for a correct and full ignition of
the burner. When no ionization is detected after 15 seconds, the ignition cycle is interrupted and the appliance will enter
into a failure condition.
When ionization is detected, the main burner will switch to full capacity. In case of an appliance with a switching second
burner, the gas valve is now opened to allow the second burner to ignite (shortly before ignition a click sound can be
heard). The appliance is now in manual mode, runs at full capacity and is now ready for operation.
The second burner can be switched on and off manually by means of the remote control and/or DRU Fire App. After the
second burner is switched on manually, the main burner first switches to full capacity to ensure a correct ignition.
2
The control unit of the appliance performs a safety check on the system every 24 hours. It is possible that this check is
performed while the appliance is in operation. In that case, the appliance will extinguish and ignite again. Repetition at
this particular time can be prevented by removing the plug from the socket and inserting it again at a time when the
appliance is rarely or never burning.
38C-0790/2
A
PowerVent®
Max. 230V~ 0,35A
(80W)
0-10V
Eco Glow®
Max. 230V~ 1A
(230W)
I nst allation manual
5 4
9-2
Summary of Contents for Maestro 60/2 Tall RCH
Page 15: ...Installation manual 15 A D B C 38C 2500 7 4...
Page 17: ...Installation manual 17 1 3 4 2 38C 2504 tooltip tooltip 7 6...
Page 19: ...Installation manual 19 38C 2793 1 2 3 4 5 6 7 7...
Page 21: ...Installation manual 21 1 3 2 4 38C 2619 586 5mm 1 2 38C 2503 7 8 7 9...
Page 23: ...Installation manual 23 5 7 8 6 38C 2507 1 60 1 3 2 4 2 mm 38C 2506 1 7 10 7 11...
Page 24: ...Installation manual 24...
Page 29: ...Installation manual 29...
Page 32: ...Installation manual 32...
Page 37: ...Installation manual 37 1 2 3 4 5 6 7 8 9 12 11 10 38C 2511 2 7 15...
Page 47: ...Installation manual 47 38P 0820 2 8 16...
Page 48: ...Installation manual 48 38P 0815 2 Eco Glow 38P 0814 2 Eco Glow 8 17 8 18...
Page 49: ...Installation manual 49 A C 38P 0816 2 B 8 19...
Page 50: ...Installation manual 50 D E 38P 0817 2 1 cm 8 20...
Page 51: ...Installation manual 51 38P 0819 0 Eco Glow F 38P 0818 0 G Eco Glow 8 21 8 22...
Page 52: ...Installation manual 52...
Page 57: ...Installation manual 57...
Page 64: ...Installation manual 64...
Page 65: ...Installation manual 65...
Page 66: ...Installation manual 66...
Page 67: ...Installation manual 67...