10. Final inspection
For a good and safe operation of the appliance, the following checks must be performed prior to commissioning.
10.1 Gas tightness
3
All connections must be gas tight. Check the connections for gas tightness. The gas control can be subjected to a
maximum pressure of 50 mbar.
10.2 Gas pressure/line-pressure
The burner pressure is set at the factory; see data plate.
3
The line-pressure in house installations must be checked, because it can be wrong.
1
Check the line-pressure. See fig. 6-1 (P1) for the measuring nipple on the gas control.
- Contact the gas company if the line-pressure is too high.
- If the line-pressure is too low, check this at the gas meter. Contact the gas company if the line-pressure is also too low
at the gas meter.
10.3 Ignition main burner
For igniting the main burner, see the User Manual.
10.3.1 First ignition of the appliance after installation or adjustments
3
- For inspection purposes, ignite the appliance without a glass pane after installation or after having performed work.
- If necessary, bleed the gas pipe.
Proceed as follows:
1. Remove the glass pane from the appliance (see section 8).
2. Ignite the appliance by means of the remote control or DRU Fire App. See section 9.1 for a step-by-step description of
the ignition process. (Go to step 11 if the burner continues to burn).
If the main burner does not ignite:
3. Reset the system by means of the remote control or DRU Fire App.
4. Repeat the ignition procedure until the main burner ignites successfully.
3
If the appliance does not ignite after three failed attempts, it will enter into a hard lock-out for 30 minutes in order to
avoid a dangerous accumulation of gas. Make sure there is no more gas present in the appliance, before a new ignition
attempt is made.
3
Consult the diagram with error messages when ignition fails after a number of attempts (see appendix 1: Malfunctions).
5. Check the flame transfer on the main burner and check that the main burner continues to burn (go to step 11 if the
burner continues to burn).
If the main burner does NOT continue to burn:
6. Mount the glass pane.
7. Reset the system by pressing the buttons ‘Ignition’ and ‘switch off’ on the remote control simultaneously.
8. Now ignite the main burner and check that it continues to burn (go to step 11 if the burner continues to burn).
3
Limit the ignition attempts with mounted glass pane to a MAXIMUM of 1 ignition attempt. Make sure there is no more
gas present in the appliance, before a new ignition attempt is made.
If the main burner again does NOT continue to burn:
9. Switch off the appliance.
10. Consult the diagram with error messages (see appendix 1: Malfunctions) (Go to step 1 once the malfunction has been
resolved).
I nst allation manual
5 8
Summary of Contents for Maestro 60/2 Tall RCH
Page 15: ...Installation manual 15 A D B C 38C 2500 7 4...
Page 17: ...Installation manual 17 1 3 4 2 38C 2504 tooltip tooltip 7 6...
Page 19: ...Installation manual 19 38C 2793 1 2 3 4 5 6 7 7...
Page 21: ...Installation manual 21 1 3 2 4 38C 2619 586 5mm 1 2 38C 2503 7 8 7 9...
Page 23: ...Installation manual 23 5 7 8 6 38C 2507 1 60 1 3 2 4 2 mm 38C 2506 1 7 10 7 11...
Page 24: ...Installation manual 24...
Page 29: ...Installation manual 29...
Page 32: ...Installation manual 32...
Page 37: ...Installation manual 37 1 2 3 4 5 6 7 8 9 12 11 10 38C 2511 2 7 15...
Page 47: ...Installation manual 47 38P 0820 2 8 16...
Page 48: ...Installation manual 48 38P 0815 2 Eco Glow 38P 0814 2 Eco Glow 8 17 8 18...
Page 49: ...Installation manual 49 A C 38P 0816 2 B 8 19...
Page 50: ...Installation manual 50 D E 38P 0817 2 1 cm 8 20...
Page 51: ...Installation manual 51 38P 0819 0 Eco Glow F 38P 0818 0 G Eco Glow 8 21 8 22...
Page 52: ...Installation manual 52...
Page 57: ...Installation manual 57...
Page 64: ...Installation manual 64...
Page 65: ...Installation manual 65...
Page 66: ...Installation manual 66...
Page 67: ...Installation manual 67...