![DROPSA VIP5 Quick Start Manual Download Page 6](http://html1.mh-extra.com/html/dropsa/vip5/vip5_quick-start-manual_2532845006.webp)
6/29
STEP 7A
If
TIMER
mode is selected – Set the lube cycle timer value
If
TIMER
mode is selected, you must determine for how long the pump must run
during each lubrication cycle. For other operation modes, the run time of the pump
is automatically determined by the end of cycle monitoring switch.
Press
MODE
key
to
SET
cycle time
Select
UP
and
DOWN
arrows to set the value
Press
OK
key to save the value
Press
UP
arrow (
NEXT
function) to move onto the next parameter.
STEP 8
Set the pause time value (
PAUSE
timer)
The
PAUSE
timer is used to set how often the VIP5 will active the pump and run a
lubrication cycle. By default, this is set to every 6 minutes
To change the setting, press
MODE
key
Then use
UP
and
DOWN
arrows to change value.
Once, you have selected your pause time, press
OK
key to save and return to the
parameter Menu
Press
UP
arrow
(
NEXT
) to move onto the next parameter.