background image

  7

9.6 PNEUMATIC CONNECTIONS 

 

Connect the air input to the push-in connector utilizing Ø6 mm nylon tubing both for the pump 
and the mixer, and provide a stop valve to permit shutting off the supply.

 

 

9.7 ELECTRICAL CONNECTIONS 

 

The only electrical connection required is that of the Samba level. (see paragraph 6 Technical 
Specifications) 
 
 

 

N.B.:

 After all connecting up has been completed ensure the tubing and cables are protected from 

impacts and are suitably secured. 
 

 

10. INSTRUCTIONS FOR USE 

 
 

10.1 STARTING THE VIP4Tools PANEL 

 

Before using the VIP4Tools panel, it is necessary to carry out some preliminary checks: 

check the integrity of the equipment 

check that the electrical and pneumatic connections have been effected correctly 

vent the residual air from the pump using the vent screw, located at the center of the 
securing screws, until lubricant exits (retighten the vent screw without using excessive 
force). 

to facilitate the venting, regulate the pumps to maximum flow and operate for some 
cycles. 

 
 

10.2 EXCLUDING LUBRICANT DELIVERY FROM AN INDIVIDUAL PUMP: 

 

 
-Unscrew (anticlockwise) the red cap at the end of the pump to its stop, so completely blocking 
off the delivery. 

 
 

10.3 REGULATING LUBRICANT DELIVERY FLOW: 

        Use the red cap to determine the nominal flow of the individual pump.  
 

- Completely unscrew the pump red regulating cap (0 mm³ flow) turn clockwise for     1.5 turns 
(min. flow 5 mm³) after which every turn corresponds to an increase in flow of 5 mm³ until 
reaching 30 mm³

 

 at the 7

th

 turn. 

(see table) 

 

 

FLOW (mm³ / stroke) 

TURNS 

30 6.5 
25 5.5 
20 4.5 
15 3.5 
10 2.5 

5 1.5 

0 = no pump delivery  

Completely unscrewed 

 
 
 
 
 
 

Summary of Contents for VIP4Air 110 V AC

Page 1: ...VIP4Air Minimal Air Oil Lubrication System Automatic Lubrication Systems...

Page 2: ...c Controls quick Set up and interfacing to host Integrated Mixing Air Pressure Transducer provides accurate and quick setting of Air Pressure on the electronic display as well as providing alarms for...

Page 3: ...tion TABLE OF CONTENTS 1 INTRODUCTION 2 IDENTIFICATION 3 GENERAL DESCRIPTION 4 DESCRIPTION OF COMPONENTS 5 TECHNICALSPECIFICATION 6 HANDLING AND TRANSPORT 7 PRECAUTION IN USE 8 CONTRAINDICATIONS 9 INS...

Page 4: ...be immediately replaced After long periods of inactivity check air tightness of all parts subjected to pressure Personnel must use personal protection equipment clothing and tools adequate for the lo...

Page 5: ...mposed of the following items a Tank made of transparent plastic material compatible with lubricants on the market a System for the regulation of the mixer air a modular Subframe a Samba type Minimum...

Page 6: ...lubrication panel The operator must understand the functioning of the unit by studying the user s manual Electric currents No intervention must be attempted on the equipment without first having disc...

Page 7: ...part VIII 626 Safety at Work legislation Use of unsuitable lubricants Main inadmissible fluids Fluid Danger Lubricants with abrasive additives High wear rate of contacted parts Lubricants with silico...

Page 8: ...placement or augmenting To install a new unit proceed as follows 1 Empty the tank of oil 2 Disconnect the air supply and unscrew the connections on the base 3 Connect the new base tightening the two s...

Page 9: ...have been effected correctly vent the residual air from the pump using the vent screw located at the center of the securing screws until lubricant exits retighten the vent screw without using excessi...

Page 10: ...ies are disconnected before undertaking any maintenance tasks 12 DISPOSAL During the maintenance of the machine or in the event of its being scrapped do not discard polluting components in the environ...

Page 11: ...FT STEEL ALLOY STEEL STAINLESS STEEL REFRACTORY AND TITANIUM ALLOYS Saw cutting Turning Shearing Cutting off 35 40 50 50 50 60 Boring Drilling Milling Slotting 40 50 50 60 70 Threading Tapping Planing...

Page 12: ...it optional P N 3132572 Number of elements Height A mm Weight Kg 1 363 2 7 2 391 3 2 3 419 3 7 4 447 4 2 5 475 4 7 6 503 5 2 7 531 5 7 8 559 6 2 Electric Level Filler plug Air mixer Regulator Delivery...

Page 13: ...it optional P N 3132572 Number of elements Height A mm Weight Kg 1 365 3 6 2 393 4 1 3 421 4 6 4 449 5 1 5 477 5 6 6 505 6 1 7 533 6 6 8 561 7 1 Electric Level Filler plug Air mixer regulator Delivery...

Page 14: ...eceipt of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perform s...

Page 15: ...manufactured in conformity with the DIRECTIVE OF THE COUNCIL OF THE EUROPEAN COMMUNITY concerning the machines 98 37 CE low voltage BT 73 23 CEE is manufactured in accordance with the following stand...

Page 16: ...br dropsa com Dropsa S p A Via B Croce 1 20090 Vimodrone MI Italy Tel 39 02 250 79 1 Fax 39 02 250 79 767 E mail sales dropsa it Export E mail vendite dropsa it National Poly Dropsa S A Av Fabregada 2...

Reviews: