background image

 

4

5. TECHNICAL SPECIFICATIONS 

 

CHARACTERISTIC 

VIP4Tools lubrication panel

 

Air supply pressure 

5 - 8 bar 

Working temperature 

-5 - +55 °C 

Working humidity 

90% max 

Permitted lubricants 

Mineral - synthetic 

Oil viscosity at working 

temperature 

32 - 320 cSt 

Conservation temperature 

-20 - +65 °C 

 

SAMBA LEVEL 

 

Temperature:  

-10°C - +80°C 

Maximum switching power: 

50W 5V 

Maximum current: 

1 A 

Maximum voltage: 

220 V ac 

 
 

WARNING:

 DO NOT supply the machine with voltages or pressures other than those indicated 

on the specification plate. 

 
 

6. HANDLING AND TRANSPORT

 

 

Prior to dispatch VIP4Tools lubrication panels are carefully packed in a cardboard carton. During 

transportation and storage maintain the equipment the right way up as indicated on the carton.  

On receipt, check that the packaging is not damaged and store the equipment in a dry place. 

 
 

7. PRECAUTIONS IN USE 

 

It is necessary to carefully read the warnings and the risks involved in using the lubrication panel. The 
operator must understand the functioning of the unit by studying  the user’s manual. 

 

Electric currents 

No intervention must be attempted on the equipment without first having disconnected the electrical 
power supply (electric level) and ensuring that it cannot be reconnected during the intervention. 
All installed equipment, electrical, electronic, tank and base structure, must be connected to the 
ground line. 

(see paragraph 10.7).

 

Flammability 

The oil employed in the lubrication circuit is not normally flammable. It is nonetheless indispensable to 
take every precaution against the oil coming into contact with very hot parts or open flames.  

Pressure 

Prior to any intervention on the equipment ensure that pressure is released from all branches of the 
lubrication circuit. Failure to do this could result in oil being discharged under pressure where 
connections or components are disassembled 

(see paragraph 10.6). 

Noise 

The VIP4Tools lubrication panel does not emit excessive noise, remaining below 70dB(A). 
 

WARNING:

 before carrying out the replacement of the mini-pumps, empty the tank of 

lubricant. 

 

 
 
 
 
 
 
 
 

Summary of Contents for VIP4Air 110 V AC

Page 1: ...VIP4Air Minimal Air Oil Lubrication System Automatic Lubrication Systems...

Page 2: ...c Controls quick Set up and interfacing to host Integrated Mixing Air Pressure Transducer provides accurate and quick setting of Air Pressure on the electronic display as well as providing alarms for...

Page 3: ...tion TABLE OF CONTENTS 1 INTRODUCTION 2 IDENTIFICATION 3 GENERAL DESCRIPTION 4 DESCRIPTION OF COMPONENTS 5 TECHNICALSPECIFICATION 6 HANDLING AND TRANSPORT 7 PRECAUTION IN USE 8 CONTRAINDICATIONS 9 INS...

Page 4: ...be immediately replaced After long periods of inactivity check air tightness of all parts subjected to pressure Personnel must use personal protection equipment clothing and tools adequate for the lo...

Page 5: ...mposed of the following items a Tank made of transparent plastic material compatible with lubricants on the market a System for the regulation of the mixer air a modular Subframe a Samba type Minimum...

Page 6: ...lubrication panel The operator must understand the functioning of the unit by studying the user s manual Electric currents No intervention must be attempted on the equipment without first having disc...

Page 7: ...part VIII 626 Safety at Work legislation Use of unsuitable lubricants Main inadmissible fluids Fluid Danger Lubricants with abrasive additives High wear rate of contacted parts Lubricants with silico...

Page 8: ...placement or augmenting To install a new unit proceed as follows 1 Empty the tank of oil 2 Disconnect the air supply and unscrew the connections on the base 3 Connect the new base tightening the two s...

Page 9: ...have been effected correctly vent the residual air from the pump using the vent screw located at the center of the securing screws until lubricant exits retighten the vent screw without using excessi...

Page 10: ...ies are disconnected before undertaking any maintenance tasks 12 DISPOSAL During the maintenance of the machine or in the event of its being scrapped do not discard polluting components in the environ...

Page 11: ...FT STEEL ALLOY STEEL STAINLESS STEEL REFRACTORY AND TITANIUM ALLOYS Saw cutting Turning Shearing Cutting off 35 40 50 50 50 60 Boring Drilling Milling Slotting 40 50 50 60 70 Threading Tapping Planing...

Page 12: ...it optional P N 3132572 Number of elements Height A mm Weight Kg 1 363 2 7 2 391 3 2 3 419 3 7 4 447 4 2 5 475 4 7 6 503 5 2 7 531 5 7 8 559 6 2 Electric Level Filler plug Air mixer Regulator Delivery...

Page 13: ...it optional P N 3132572 Number of elements Height A mm Weight Kg 1 365 3 6 2 393 4 1 3 421 4 6 4 449 5 1 5 477 5 6 6 505 6 1 7 533 6 6 8 561 7 1 Electric Level Filler plug Air mixer regulator Delivery...

Page 14: ...eceipt of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perform s...

Page 15: ...manufactured in conformity with the DIRECTIVE OF THE COUNCIL OF THE EUROPEAN COMMUNITY concerning the machines 98 37 CE low voltage BT 73 23 CEE is manufactured in accordance with the following stand...

Page 16: ...br dropsa com Dropsa S p A Via B Croce 1 20090 Vimodrone MI Italy Tel 39 02 250 79 1 Fax 39 02 250 79 767 E mail sales dropsa it Export E mail vendite dropsa it National Poly Dropsa S A Av Fabregada 2...