4. TECHNICAL CHARACTERISTICS 

 
 
 
 
 
 
 
 
 
 
 
                                                                     

                                                                                                                                                        
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

N.b. The specifications refer to the temperature of use of +20°C (+68°F) 

(1)

 revolutions with load less motor

 

* If a different product is used, please contact Dropsa S.p.A. to ensure it is suitable for use (see page 12) 

 

GENERAL CHARACTERISTICS 

Empty weight 

6.2 Kg 

ELECTRICAL CHARACTERISTICS

 

Motor power supply 

230-400  V - 50 Hz  
265-460 V - 60  Hz 
110 V 50 Hz single phase 4p  
230 V 50 Hz single phase 4p 
24 V CC 2800 rpm 

(1)

 

Rated motor power 

0.09 Kw – 0.11 Kw 

Degree of motor protection 

IP 55 

Minimum level 

Optical (oil and fluid grease versions ) / With floating switch (only oil 
version)  

Optical  power supply level  

8÷28 V DC inversion protected 

Optical level output signal 

Type NPN/PNP short-circuit protected, off in the case of minimum 
level. Max 1.7A 

Optical  LED signal 

Active when tank is not empty 

Level connector (optical-

 

floating switch) 

DIN 43650 

Float Level output signal

 

 

Clean contact 50V max voltage, 40 W max power. SPDT 

Contact.

 

Pressure switch 

Contact closed in the case of max calibration pressure alarm    

(3-18-30 bar) 

Pressure switch output signal 

Voltage free contact max voltage 42V, max. power 100 W 

HYDRAULIC CHARACTERISTICS

 

Pumping system 

Gear pump 

Flow rates (1500 rpm) 

350 cc/min - 500 cc/min (three-phase/single-phase versions) 
600 cc/min - 850 cc/min (24V

 DC

 version

)

 

 

Maximum operating pressures 

 - 70 bar -three-phase motor (with intermittent service max 5 min 

with pause ratio 1:1)  

 - 40 bar (single-phase motor) 
 - max 30 bar with continuous service  

Outlet connection 

G1/8” BSP 

Tank capacity 

3L/6L 

Filter 

Degree of filtering 1000 µ 

By-pass 

Adjustable 0 ÷70 bar – precalibrated 40bar (35bar for single-phase 
motors) 

Temperature of use 

+ 5 

 + 70 

Operating humidity 

90 % rel. humidity 

Permitted lubricants * 

Mineral lubricating oil 32 cSt; grease max NLGI000

 

Storage temperature 

-20 

 +65 °C 

Continuous sound pressure level 

< 70 dB(A) 

 

three-phase 

Summary of Contents for 3905000

Page 1: ...ACTERISTICS 5 COMPONENTS 6 UNPACKING AND INSTALLING 7 OPERATING INSTRUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION...

Page 2: ...versatility when used with press lubrication systems machine tools reducers guides chains etc The DRAGON X pump has a built in release valve and can be used in the following types of systems Lubricati...

Page 3: ...el connector optical floating switch DIN 43650 Float Level output signal Clean contact 50V max voltage 40 W max power SPDT Contact Pressure switch Contact closed in the case of max calibration pressur...

Page 4: ...4 4 1 HYDRAULIC SYSTEM The only connection to make is to connect the pump to the point to lubricate or to the metering valves Fig 2 Hydraulic diagram with check valve Fig 1 Hydraulic diagram...

Page 5: ...mounting suitable space must be provided see the installation diagram to prevent abnormal positions or the possibility of impacts fixing holes are provided on the plate see Para 12 Then the pump must...

Page 6: ...the level is off see the image below 4 Turn the screw in opposite way until the green led is on At the end of this procedure the level is correctly set It is possible to re do the calibration followi...

Page 7: ...ions Check the integrity of the pump Check that the pump is at the operating temperature and that there are no air bubbles in the pipes Check that the electric connection was carried out correctly Che...

Page 8: ...e by pass valve Replace the pump Tighten the adjustment screw until oil comes out of the delivery pipe Replace the by pass valve Connect a pipe that is approx 30 cm long to the pump outlet with a pres...

Page 9: ...an improper manner Refer to the local regulations for their correct disposal When demolishing the machine the identification plate and all other documents must be destroyed 11 ORDER INFORMATION 11 1...

Page 10: ...SENSOR LEVEL For the 3L tank 1639201 For the 6L tank 1639202 FLOATING LEVEL INDICATOR For the 3L tank 3133627 For the 6L tank 3133628 DISTRIBUTOR BLOCK 1525370 TANK 3 L 6770033 6 L 6770006 PRESSURE G...

Page 11: ...11 12 DIMENSIONS CONTROL UNITS A B C D E F G 3L pump 330 146 246 195 152 172 80 6L pump 431 250 347 259 148 172 80 3L 24V pump 312 146 246 173 150 151 75 6L 24V pump 413 250 347 253 150 151 75...

Page 12: ...ations Electric current Do not carry out any work on the machine before disconnecting it from the electrical power supply and making sure that no one can reconnect it during the operation All the inst...

Page 13: ...nts and the provisions specified in the machine directive was checked by filling out prepared check lists that are contained in the technical file Two types of lists were used Risk assessment UNI EN I...