background image

4 of 10 

2.0 

TECHNICAL SPECIFICATIONS 

 

2.1

 

Methods of commanding the pump 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2.2  

Other data 

 

Viscosity of the lubricant at working temperature 

Between 115 - 2000 cSt 

Working temperature 

+ 5 - + 50  C 

Working humidity 

90 % relative humidity. 

Preservation temperature 

- 20 - + 50  °C 

Sound pressure level  

< 70 dB(A) 

 

Manual push-button control 

 

Discharge 

 

Supply 

 

3-way solenoid valve control 

 

Discharge 

 

Supply 

 

Mechanical roller cam or cam bar 
control 

 

Discharge 

 

Supply 

 

Summary of Contents for 31070 Series

Page 1: ...nslation Warranty Information CONTENT 0 0 INTRODUCTION 1 0 DESCRIPTION OF THE PUMP 2 0 TECHNICAL SPECIFICATIONS 3 0 CORRECT USE 4 0 DIMENSIONS 5 0 DECLARATION OF CONFORMITY 6 0 DISTRIBUTORS The manual...

Page 2: ...connections can cause serious safety problems and all such connections should be checked before and after installation and tightened if necessary Never exceed the maximum operating pressure values al...

Page 3: ...s available with characteristics Part number pressure c c stroke tank syst ratio min level weight dimensions min max useful max litres electric Kg lxdxh mm 3107000 15 30 7 5 15 0 4 06 1 1 no 1 54 84x9...

Page 4: ...working temperature Between 115 2000 cSt Working temperature 5 50 C Working humidity 90 relative humidity Preservation temperature 20 50 C Sound pressure level 70 dB A Manual push button control Disc...

Page 5: ...any level and pressure switches to the control panel The minimum level indicator is supplied unless otherwise specified by the customer with the contact closed for minimum level Should the user requir...

Page 6: ...e springs the component parts of the pump unit can then be disassembled 5 remove the screws which retain the flange so releasing the complete pump unit In this way all component parts of the pump unit...

Page 7: ...s list of dangers as in EN 414 referring to EN 292 application of essential safety requirements Machine Dir electrical safety requirements EN 60204 1 The following is a list of dangers which have not...

Page 8: ...3 90 54 93 12 M10x1 M10x1 62 210 3107002 79 170 54 100 12 M14x1 5 M14x1 5 132 294 3107006 110 90 54 93 12 M10x1 M10x1 62 250 3107010 110 90 54 93 12 M10x1 M10x1 62 250 3107021 77 170 54 100 7 5 M14x1...

Page 9: ...ne named que la machine d nomm e Die Maschine mit der Bezeichnung que la m quina denominada que o equipamento denominado SERIES 31070 HYDRAULICALLY DRIVEN PUMP conforme alle condizioni previste dalle...

Page 10: ...esuk dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerl...