background image

 

 

Page 11  

7.

 

DISTRIBUTORS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Web site: 

http://www.dropsa.com

 

 -  E-mail: 

[email protected]

 

 

 

Dropsa S.p.A. 

Via B. Croce,1  

20090 Vimodrone (MI) Italy. 

Tel: (+39) 02 - 250.79.1  

Fax: (+39) 02 - 250.79.767 

E-mail: [email protected] (Export) 

E-mail: [email protected] (National) 

 

 

Dropsa Ame 

23, Av.des.Morillons  

Z.I. des Doucettes 91140 

 Garges Les Gonesse, France 

Tel: (+33) 01 39 93 00 33  

Fax: (+33) 01 39 86 26 36 

E-mail: [email protected] 

 

 

Dropsa (UK) Ltd 

Unit 6, Egham Business Village, 

Egham,Surrey,TW20 8RB 

Tel: (+44) 01784 - 431177  

Fax: (+44) 01784 - 438598 

E-mail: [email protected] 

 

 

Dropsa do Brazil Ind. E Com. Ltda 

Rua Sobralia 175,    

Sao Paulo, Brazil 

Tel: (+55)  011-5631-0007  

Fax: (+55)  011-5631-9408 

E-mail: [email protected]

 

 

Dropsa USA Inc. 

6645 Burroughs Ave  

48314-2132 Srerling Hts,Mi Us -USA  

Tel: (+1) 586-566-1540  

Fax: (+1) 586-566-1541 

E-mail: [email protected] 

  

Dropsa Lubrication Systems 

Nr 8 Dongxing Road,  

Songjiang Industrial Zone  

(Shanghai) Co., Ltd 

Tel: +86 (021) 67740275 

Fax: +86 (021) 67740205 

E-mail: [email protected] 

 

 

Dropsa Gmbh

 

Volmerswerther Strasse 80  

40221 Dusseldorf 1, Deutschland  

Tel: (+49) 0211/39 4011  

Fax:(+49) 0211/39 4013  

E-mail[email protected] 

 

 

 

Dropsa Australia  Pty. 

C20/148 Old Pittwater Road 

Brookvale, NSW 2100 

Tel:  +61 (02) 9938 6644 

Fax: +61 (02) 99 386 611  

E-mail[email protected]  

 

Summary of Contents for 31030 Series

Page 1: ...ti io on n S Sy ys st te em ms s S Sh ha an ng gh ha ai i C Co o L Lt td d t t 8 86 6 0 02 21 1 6 67 77 74 40 02 27 75 5 f f 8 86 6 0 02 21 1 6 67 77 74 40 02 20 05 5 U U S S A A D Dr ro op ps sa a C...

Page 2: ...the pump risks to persons and cause pollution The loosening of connections can cause serious safety problems and all such connections should be checked before and after installation and tightened if n...

Page 3: ...0 8 04 8 5 1 yes 2 142x123x296 3103036 4 7 3 5 7 5 no 04 8 5 1 yes 8 240x130x320 3103038 4 7 3 5 7 5 no 04 8 5 1 no 1 6 Diam 78x142 3103001 4 7 7 5 15 0 4 06 4 1 no 2 26 84x103x253 3103002 4 7 7 5 15...

Page 4: ...working temperature Between 15 1000 cSt Working temperature 5 40 C Working humidity 90 relative humidity Preservation temperature 20 50 C Sound pressure level 70 dB A Manual push button control Supply...

Page 5: ...le lubricant min max indication on the tank Verify that the pump is at operating temperature and the tubing free from air bubbles Check that the electrical connections have been effected correctly CEI...

Page 6: ...is recommended and the periodic careful cleaning of the component parts of the pump Disassembly must be effected in the following manner 1 Disconnect the tubing attached to the pump 2 Remove the fixin...

Page 7: ...in the exact quantity prescribed The pump does not deliver oil at the prescribed pressure PROBABLE CAUSE The oil in the tank is below the minimum level The suction filter is dirty or blocked The pump...

Page 8: ...equirements for the use of suitable personal protective clothing Use of unsuitable lubricant the characteristics of the fluid are shown on the pump and in the manual in case of doubt contact the Eng D...

Page 9: ...5 M14x1 5 170 390 135 54 3103015 100 12 132 M14x1 5 M14x1 5 170 390 135 54 3103025 93 12 62 M10x1 M10x1 90 253 116 54 3103026 100 12 132 M14x1 5 M14x1 5 170 390 135 54 3103029 100 12 132 M14x1 5 M14x1...

Page 10: ...ome Commerciale Product Name D nomination Handelsname Denominaci n Denomina o Versioni Versions Versions Versionen Versiones Vers es Tutte Codici Codes C digos Serie 31030 conforme alle condizioni pre...

Page 11: ...suk dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerli...

Reviews: