3.3.4
Floor protection
-
If the floor is made of non-
combustible material, no floor
protector is required.
-
If the floor is made of combustible
material, a floor protector is required
(see table below).
FLOOR PROTECTION*
CANADA
USA
A
18" (457 mm) From door opening
16" (406 mm) From door opening
B
N/A (USA only)
8" (203 mm)
From door opening
C
8" (203 mm)
N/A (Canada only)
D
8" (203 mm) – Note 1
N/A (Canada only)
E
N/A (USA only)
2” (51 MM) - Note 2
F
43 ¾’’ (1111 mm)
30 ¼’’ (769 mm)
G
74’’ (1880 mm)
64’’ (1626 mm)
*Steel with a minimum thickness of 0.015" (0.38 mm) or ceramic tiles sealed together with
grout. No protection is required if the unit is installed on a non-combustible floor (ex:
concrete).
Note 1:
The floor protection at the back of the furnace is limited to the furnace’s required
clearance (see (A) 3.3 Clearances to combustible material) if such clearance is smaller than
8" (203 mm).
Note 2:
Only required under the horizontal section of the connector. Must exceed each side
of the connector pipe by at least 2" (51 mm).
Summary of Contents for DF02003
Page 2: ......
Page 24: ...Install the cover on the part B of the assembly and secure it with 16 screws C...
Page 35: ...Heat Commander Furnace Installation and Operation Manual 35 7 1 1 Electrical Diagram...
Page 73: ...Heat Commander Furnace Installation and Operation Manual 73 12 Exploded diagram and parts list...
Page 74: ......
Page 75: ...Heat Commander Furnace Installation and Operation Manual 75...
Page 76: ......
Page 77: ...Heat Commander Furnace Installation and Operation Manual 77...
Page 78: ......
Page 79: ...Heat Commander Furnace Installation and Operation Manual 79...
Page 85: ...Heat Commander Furnace Installation and Operation Manual 85 13 2 1 Technical data...
Page 86: ......
Page 91: ...Heat Commander Furnace Installation and Operation Manual 91...
Page 92: ......