![Drija BARI 60 User Manual Download Page 16](http://html.mh-extra.com/html/drija/bari-60/bari-60_user-manual_2531326016.webp)
User manual
ELECTRIC STOVE BUILT - IN | BARI 60
15
The cable connections must be in accordance with the diagram located on the bottom of
the hob.
The brass links must be positioned as marked in the appropriate diagram and once
established ALL terminal screws must be tightened down firmly.
If when the hob is first switched on, only two of the zones work, you should
recheck that the terminal screws are all fully tightened between the links.
IMPORTANT:
The appliance must NOT be connected to the mains supply by means of
a 13A plug and socket.
The cable can be looped if necessary, but make sure that is not
Kinked or trapped when the hob is in position. Care must be taken to avoid the cable
being in contact with hot parts of the appliance.
REPLACING THE MAINS SUPPLY CABLE
If the mains supply cable is damaged, then it must be replaced by an appropriate replacement
which can be obtained from the Seller. The mains supply cable should be replaced in
accordance with the following instructions:
Switch the appliance off at the control switch.
Open the terminal block on the underside of the hob.
Unscrew the terminal screws fixing the cable.
Replace the cable with one of the same length and in accordance
With the specification given above.
The “green-yellow” earth wire must be connected to the terminal marked. It must be
about 10 mm longer than the live and neutral wires.
The “blue” neutral wire must be connected to the terminal marked with letter (N) - the
live wire must be connected to the terminal marked with letter (L).
220V 1N