Connection with steel tube:
• Only use stainless steel hoses that comply with the relevant regulations, and
always seal C properly fit between fitting A and hose E.
When connecting with a hose, make sure that the length of the pipe is not more than
2 meters; also make sure that the hose does not touch moving parts or that it is
crushed.
3. ADAPT TO OTHER TYPES OF GAS
Before proceeding with the adaptation, disconnect the appliance from the electric
current.
The apparatus was tested with G20 (2H) natural gas at a pressure of 20mbar. If it
will be used with another type of gas, its nozzle must be changed and the gas valve
must be adjusted. To replace the nozzle, proceed as described below.
Setting the oven burner
To adjust the oven burner, open the oven door and
proceed as follows:
• Remove all accessories (grills, shelves and any steel
corridor).
• Lift the bottom plate of the oven and remove so that
the inside of the oven is as shown in the picture.
Minimum setting
The oven thermostat has a screw to regulate the
minimum programming, accessible by removing the
thermostat knob. When the gas type is changed, the
minimum programming must be adjusted following these
specifications:
Turn on the oven burner and keep it in operation at high temperatures for 10
to 15 minutes with the door closed. Then turn the knob to the minimum
temperature, remove the knob and use a flat screwdriver to adjust. First, turn
the knob clockwise tightly counterclockwise to adjust the flame. For natural
gas you should rotate 1/8 circle while 5/8 circle for LPG.