108248F (07-01502) F203-A 110V UK 1200EB
4
Legend Brands Europe Holdings Ltd.
The correct humidity value is displayed in the humidity
display area. If a fault is detected, an error code will
display in thisarea.
7. Error codes
The table below shows error message that the system
may detect. If the display shows an “ER” message, first
unplug the unit and then plug it back in. This may re-set
the electronics, and if so, no further action is required. If
the error message reappears, try the solution shown
under “Explanation.” If this still does not fix the problem,
contact your local Dri-Eaz distributor for further
assistance.
E R R O R
C O D E
E X P L A N A T I O N
ER 3
Humidity sensor failure. Contact Dri-
Eaz.
ER 4 + beep
Condensate tank full or sensor failure.
Unit stops and the beeper sounds
twice every 5 minutes. Check drain
hose for clogs and kinks. If problem
persists, contact Dri-Eaz.
ER 5
Coil sensor out of temperature range
or failure. Turn unit off and allow unit
to return to room temperature. Turn
unit on. If ER 5 displays again, sensor
has likely failed. Contact Dri-Eaz.
At the end of the job
As with all dehumidifiers, once the drying job is
completed, it is important to make sure the unit is
completely purged of water before moving it.
To ensure
that all water has drained into the pump basin, turn
the unit off, wait for 10 minutes, then press the
PURGE button.
(The unit must be plugged in for the
purge to operate.) Once the purge cycle is complete,
unplug the unit and remove it promptly from the job.
Before transporting, be sure to remove the external drain
hose and drain it carefully.
MAINTENANCE
WARNING! ELECTRIC SHOCK HAZARD.
Unplug the
1200EB before performing any maintenance.
Before each use
Inspect the electrical cord for damage.
Look for
fraying, cuts, etc. Do not use the unit if you find any
damage. Contact your local Dri-Eaz distributor for
assistance.
Inspect and replace filter as needed.
The 1200EB is
equipped with a disposable 4-PRO filter. Keep a clean
filter in the unit at all times to protect internal
components from dust and other particulate build-up.
Replace filter only with a 4-PRO Filter #100250 (F581).
For parts and service call your local distributor or contact
your local Dri-Eaz distributor.
CAUTION:
Dust can cause the unit to overheat and shut
down. Do not operate when excessive dust or airborne
particles are present, such as during sanding or spray-
painting. Inspect and clean air filter elements and coils
frequently.
IMPORTANT: Replace the 4-PRO filter whenever it
has been used on a mold remediation job or
otherwise exposed to potentially dangerous
contaminants.
Monthly
Check coils
. Dirty coils can cause the unit to overheat.
Clean when visibly dirty. See Fig. B.
1. Unplug unit.
2. Remove housing, locate coils and allow coils to dry if
wet.
3. Vacuum both sides of the coils until clean, being
careful not to let the nozzle touch the fins; as damage
may result.
Check catch basin tray.
Clean when dirt and debris are
present. Wipe clean with a rag.
Check drain hose.
1. Look for obstructions. Disconnect and clear any debris
present.
2. Reattach gravity drain hose.
Annually
Have the pump system inspected by a qualified service
center.
Catch basin
tray
Coils
Pump
FIG. B: CLEANING