background image

108248F (07-01502) F203-A 110V UK 1200EB 

Legend Brands Europe Holdings Ltd. 

The correct humidity value is displayed in the humidity 

display area. If a fault is detected, an error code will 

display in thisarea.  

7. Error codes 

The table below shows error message that the system 

may detect. If the display shows an “ER” message, first 

unplug the unit and then plug it back in. This may re-set 

the electronics, and if so, no further action is required. If 

the error message reappears, try the solution shown 

under “Explanation.” If this still does not fix the problem, 

contact your local Dri-Eaz distributor for further 

assistance.  

E R R O R

 

C O D E  

E X P L A N A T I O N  

ER 3 

Humidity sensor failure. Contact Dri-

Eaz. 

ER 4 + beep 

Condensate tank full or sensor failure. 

Unit stops and the beeper sounds 

twice every 5 minutes. Check drain 

hose for clogs and kinks. If problem 

persists, contact Dri-Eaz.  

ER 5 

Coil sensor out of temperature range 

or failure. Turn unit off and allow unit 

to return to room temperature. Turn 

unit on. If ER 5 displays again, sensor 

has likely failed. Contact Dri-Eaz.   

 

At the end of the job 

As with all dehumidifiers, once the drying job is 

completed, it is important to make sure the unit is 

completely purged of water before moving it. 

To ensure 

that all water has drained into the pump basin, turn 

the unit off, wait for 10 minutes, then press the 

PURGE button. 

(The unit must be plugged in for the 

purge to operate.) Once the purge cycle is complete, 

unplug the unit and remove it promptly from the job.

  

Before transporting, be sure to remove the external drain 

hose and drain it carefully.  

MAINTENANCE 

WARNING! ELECTRIC SHOCK HAZARD.

 Unplug the 

1200EB before performing any maintenance. 

Before each use 

Inspect the electrical cord for damage.

 Look for 

fraying, cuts, etc. Do not use the unit if you find any 

damage. Contact your local Dri-Eaz distributor for 

assistance. 

Inspect and replace filter as needed.

 The 1200EB is 

equipped with a disposable 4-PRO filter. Keep a clean 

filter in the unit at all times to protect internal 

components from dust and other particulate build-up.  
Replace filter only with a 4-PRO Filter #100250 (F581). 

For parts and service call your local distributor or contact 

your local Dri-Eaz distributor. 

CAUTION: 

Dust can cause the unit to overheat and shut 

down. Do not operate when excessive dust or airborne 

particles are present, such as during sanding or spray-

painting. Inspect and clean air filter elements and coils 

frequently.

  

IMPORTANT: Replace the 4-PRO filter whenever it 

has been used on a mold remediation job or 

otherwise exposed to potentially dangerous 

contaminants.  

Monthly 

Check coils

. Dirty coils can cause the unit to overheat. 

Clean when visibly dirty. See Fig. B. 
1. Unplug unit.  
2. Remove housing, locate coils and allow coils to dry if 

wet. 
3. Vacuum both sides of the coils until clean, being 

careful not to let the nozzle touch the fins; as damage 

may result.  

Check catch basin tray. 

Clean when dirt and debris are 

present. Wipe clean with a rag. 

Check drain hose.  

1. Look for obstructions. Disconnect and clear any debris 

present. 
2. Reattach gravity drain hose. 

Annually 

Have the pump system inspected by a qualified service 

center. 

Catch basin 

 tray 

Coils 

Pump  

FIG. B: CLEANING 

 