background image

108248F (07-01502) F203-A 110V UK 1200EB 

Legend Brands Europe Holdings Ltd. 

Turn the unit on 

Press the “on” button on the control panel. 

How to use the control panel 

The display panel uses an LCD liquid crystal display 

featuring a blue backlight. The display provides a variety 

of information about the unit and the operating 

environment, including dehumidification mode, defrost 

cycle, water full indicator, fan operation indicator, relative 

humidity, total run time, and error codes.  

1. Control Panel Buttons 

When any button is pressed, the backlight turns on. The 

backlight goes off after 30 seconds.  

1.1 ON/OFF 

 key:

 Each time the ON/OFF key is 

pressed, the controller will cycle “on-off-on”. When the 

unit is first plugged in, the unit will complete an 

automatic self-test before the ON/OFF are available for 

use.  

1.2 Up 

▲key:

 Increase humidistat setting. Each press 

increases the setting in 1% RH increments to a 

maximum of 90% RH. Holding the key will increase the 

setting in 5% RH increments each second. Release the 

key to accept the desired RH setting.  

1.3 Down 

▼key:

 Decrease humidistat setting. Each 

press decreases the setting in 1% RH increments to a 

minimum of 30% RH. Holding the key will decrease the 

setting in 5% RH increments each second. Release the 

key to accept the desired RH setting. 

1.4 Purge 

 key:

 Use this button to pump out the 

condensate tank. The pump operates for approximately 

30 seconds. 

2. Functional mode description 

2.1. Humidistat operation 

1) Press ▲and ▼ to adjust the 

dehumidification level. 

The available range is 30%–90% RH. The default 

humidity setting is 60% RH.  

NOTE: To operate the unit in continuous 

dehumidification mode

, press 

the ▼key 

until the 

30% RH setting is displayed, and then press the 

▼key 

again. The panel will display "CO" indicating 

the unit has entered continuous dehumidification 

mode. When setting the humidity, the set humidity 

display flashes. If no keys are pressed for 5 

seconds, the the screen will show ambient humidity.  

2) T Environment humidity -

T set humidity ≥3, the 

compressor and fan on.  
3) T Environment humidity-T set humidity 

-3, the 

compressor stops and the fan runs. The compressor 

restart needs to meet: T Environment humidity-T set 

humidity 

≥3 and 3 minutes delay

 

3. Operation control description 

Any time the unit is turned off or power is interrupted, the 

system initiates a 3-minute delay before the unit can be 

turned on again.  

3.1 Defrost Function 

If the system detects the build-up of ice on the coil, the 

unit will go into defrost mode and the defrost icon will 

display. When the defrost cycle is complete, the defrost 

icon will turn off and the unit will automatically resume 

normal operation.   

3.2 Condensate Tank Full 

When the condensate tank is, the pumpout icon on the 

panel will display and the pump will operate for 

approximately 20 seconds until it detects no more water 

in the tank. If the system continues to detect water after 

40 seconds, the pump will stop and the system will 

display the error code E4 and beep twice every 5 

minutes. Check the drain hose for kinks and clogs.  

3.3 Memory function:  

When shut off normally, the unit will retain humidistat 

values set by the user. If power is interrupted, the unit 

will default to 60% RH.  

4. Sensor Errors 

If the humidity sensor fails, the humidity cannot be set, it 

automatically switches to continuous dehumidification. 

The display shows the humidity sensor fault with code 

E3. If the coil probe fails, the unit will not operate, and 

the display will show E5. See "Error Codes" table below.  

5. Accumulated working time 

When the power button is on, the timer starts to count by 

minute. After powering off and restarting, the timer count 

resumes. The memory of accumulated time is 

permanent and cannot be reset. Time data is written into 

the memory every 10 minutes, and the accumulated 

maximum time is 99999 hours and 59 minutes. 

6. Dehumidification icon 

In the dehumidification mode, the dehumidification icon 

displays while the compressor is operating. The 

dehumidification icon flashes when the compressor is 

not working, such as during defrost mode.  