READ AND SAVE THESE INSTRUCTIONS
Note: To be assured of true HEPA Oration, change the HEPA filter after
every water damage job. or when the indicator light comes on. whichever occurs
first
When using the DefendAir HERA 500 for remediation:
After every job
• Replace both the filters to prevent cross-contamination.
• Clean the unit thoroughly (vacuum and damp wipe per IICRC 5520, 10.11)
after each job before removing it from the containment area to avoid cross-
contamination. Pay particular attention to the area around the air intake. Let
the unit dry before installing clean filters.
TROUBLESHOOTING
For any problems not listed below, call your local distributor or contact our Service Department toll free at 888-867-
3235.
PROBLEM
CAUSE
SOLUTION
Unit does not operate
•
No power to machine
•
Switch not turned on
•
No power to outlet
•
GFCI Tripped
•
Plug in the unit, check power at outlet
•
Turn on the switch
•
Reset circuit breaker/GFC1
•
Reset circuit breaker/GFCI
Change light illuminated
•
Primary filter is full
•
Air intake restricted
•
Replace the filters; refer to Maintenance section
•
Eliminate bends/kinks in ducting, or remove
ducting
Blower wheel not turning
•
Obstructed blower
•
Loosen blower wheel set screw
•
Remove obstruction
•
Tighten set screw
SPECIFICATIONS
MODEL
F284
CONTROLS
TOUCHPAD
TYPE
115V
FILTERS
PRE-FILTER
(P/N
13-00199)
PRIMARY
HEPA
P/N
(F321)
VARIABLE CFM
250-500
CFM
HANDLE
ROTOMOLDED
HEIGHT
24.6' (62.5 CM)
HOUSING
ROTOMOLDED
WIDTH
262' (66.5 CM)
POWER 115V
3
AMPS
DEPTH
18.2' (46.2 CM)
CORD LENGTH
25
FT
(7.6 M)
USE WEIGHT
44 (19.9
KG)
SAFETY
UL LISTED
SHIP WEIGHT
46 (20.9
KG)
FREQUENCY (HERTZ)
60
6