14. General information

Repair and maintenance work at the 
PCU LED may only be performed by spe-
cialists. The power supply to the device 
must disconnected in any case.
The company Dreve will be responsi-
ble for the safety, reliability and per-
formance of the device, if
· the device is only used for the appro-
priate application purpose.
· the operation is only carried out by 
professionally trained personnel.

· the device is used in accordance with 
these operating instructions.
· extensions, new settings, changes or 
repairs are only performed by authori-
sed persons.

Since we at Dreve are constantly wor-
king on the further development of our 
products, we cannot exclude the possi-
bility of technical changes.

Summary of Contents for PCU LED

Page 1: ...or use PCU LED Pioneering Technology Dreve Firmengruppe Max Planck Stra e 31 59423 Unna Germany deutsch english Lichtpolymerisationsger t f r den CAD CAM 3D Druck Prozess Light polymerization device f...

Page 2: ......

Page 3: ...satzteilliste Seite 21 14 Allgemeine Hinweise Seite 22 15 Garantie Seite 23 16 Au erbetriebnahme des Produkts Seite 23 1 Device description page 24 2 Technical data page 25 3 Declaration of conformity...

Page 4: ...tungskosten einher gehen 1 Ger tebeschreibung b Elektronische Steuerung Mikrocontroller Durch den Einsatz eines Mikrocontrollers k nnen Strom Druck und Tempera tursensoren angesteuert und ausgele sen...

Page 5: ...entnommen werden g Offenes System In der PCU LED sind 10 frei programmier bare Speicherpl tze nutzbar Tabelle 1 Aush rteumgebung f r verschiedene Anwendungen Umgebung Anwendung PCU LED Vakuum PCU LED...

Page 6: ...icherheit von Maschinen Allgemeine Gestaltungsleits tze Risikobeurteilung und Risikominderung ISO 12100 2010 Deutsche Fassung EN ISO 12100 2010 2014 35 EU Niederspannungsrichtlinie Sicherheit von Masc...

Page 7: ...9423 Unna Germany Tel 49 2303 8807 0 Fax 49 2303 82909 E Mail info dreve de www dreve com 4 Sicherheitshinweise 1 Das Ger t darf nur entsprechend der vorliegenden Bedienungsanleitung ver wendet werden...

Page 8: ...rwenden 13 BeiAnschlie en der Gasdruckflasche mit dem Ger t berpr fen Sie die Dich tigkeit des Zuf hrungsschlauches Stellen Sie sicher dass die Gasdruckflasche nicht umkippen kann 14 Verbinden Sie nie...

Page 9: ...stattung 1x PCU LED 1x Zubeh rpaket Das Zubeh r besteht aus 3x Netzwerkkabel 1x Bedienungsanleitung 1x Gasanschlussleitung Kit inkl Schnellkupplung und 2x Schlauchklemmen nur f r Stickstoff Variante h...

Page 10: ...deransicht Display Deckel Eingabeknopf R ckansicht Regelnadelventil f r Stickstoffsp lung Anschlussbuchse Stromversorgung USB Anschluss Hauptschalter Stickstoff Anschluss f r Stickstoffvariante der PC...

Page 11: ...tigen kann Die zweite Ebene ist die Prozesseignerebene in dieser kann der Prozesseigner verschiedene Ger te konfigurationen vornehmen 1 Durch Einschalten des Netzschalters an der R ckseite des Ger te...

Page 12: ...inschalten des Ger tes Welcome Bildschirm Auswahl der Materialparameter Wird ein Parametersatz ange w hlt dann wird dieser im Display hervorgehoben Durch zus tzliches Best tigen gelan gen Sie in das S...

Page 13: ...ck mbar 5 Belichtungsicon ON OFF 6 Belichtungsatmosph re Luft Vakuum Stickstoff Bel ften des Belichtungsraumes Warten bis das Vakuum abge baut ist damit z B nicht die Dichtung f r die Belichtungs kamm...

Page 14: ...bersicht 1 Orientierungsstrich Am linken und rechten Rand des angew hlten Fensters befindet sich als Orientierungshilfe jeweils ein senkrecht ausgerichteter schma ler Strich Auswahl der Prozessparame...

Page 15: ...elichtungsdauer Einstellen der LED Intensit ten Die Intensit t kann in Prozent pro Panel eingestellt werden Auf jedem Panel befinden sich 3 LED Spots Achtung Werden die vorgege benen Werte f r das jew...

Page 16: ...eitstempel der Pro zessaufzeichnung die u a im Finalen Screen im Anwender level angezeigt wird Werkseinstellung Beim R ckstellen auf die Werkseinstellung werden die individuellen Parametereinstel lung...

Page 17: ...ch Reinigung des Geh uses mit einem milden Reinigungsmittel w chentlich Wartungseinheit Wartungsh ufigkeit berpr fen ob die LED Panels kalibriert oder gewechselt werden m ssen w chentlich Check ob das...

Page 18: ...elle 1 und 2 Minuten Stelle 3 und 4 Sekunden 1 Vakuum AN 1 AN 0 AUS 0 Stickstoff AUS 1 AN 0 AUS Aufschl sseln der Fehlercodes im finalen Screen in der Anwenderebene Code Zustand Hintergrundanzeige 00...

Page 19: ...ern der Deckeldichtung Schl uche des Vakuumsystems undicht Erneuern der Schl uche Vakuumpumpe defekt Austauschen der Vakuumpumpe 03 LEDs funktionieren nicht Deckel nicht geschlossen Deckel schlie en D...

Page 20: ...23 1 2 3 9 12 14 16 19 21 25 26 32 20 24 31 32 33 27 29 30 15 34 Posnr 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 24 25 26 27 28 29 30 31 32 33 34 35 6 D C B A E F G H 5 4 3 2 1 7 1 2 3...

Page 21: ...n Displayabdeckung 521057 15 Abdeckung Messdurchf hrung 521063 16 Vakuumpumpe konfektioniert 521064KM32 17 UK Netzstecker gewinkelt 51284 18 Platine 521065 19 Kabelbaum PCU LED mit USB Buchse 521066 2...

Page 22: ...i stung des Ger tes verantwortlich wenn das Ger t nur f r den entsprechenden Anwendungszweck verwendet wird die Bedienung nur durch fachlich geschultes Personal erfolgt das Ger t in bereinstimmung mit...

Page 23: ...hlerhafter oder nicht bestimmungsge m er Behandlung berm iger Bean spruchung ungeeigneter Betriebsmittel und solcher chemischer elektrochemischer oder elektrischer Einfl sse entstehen die nach dem Ver...

Page 24: ...f a micro controller allows for 1 Device description the control and reading of the current pressure and temperature sensors c Logging and Monitoring The information which is recorded by the current p...

Page 25: ...vironment for different uses Environment Use PCU LED vacuum PCU LED nitrogen Vacuum Curing of labora tory products Nitrogen Curing of medical devices Weight of the overall package 11 1 kg Weight of th...

Page 26: ...of machinery General principles for design Risk assessment and risk reduction ISO 12100 2010 German Version EN ISO 12100 2010 Corrigendum to DIN EN ISO 12100 2011 03 2014 35 EC Low Voltage Directive...

Page 27: ...The device must only be used in accordance with the present operating instructions We do not assume any liability for damages which result from improper use and or faulty operation 2 Only operate the...

Page 28: ...pressure of 5 bar 70 psi 15 Please close the gas supply when the device is not used Do not operate the device unattended 16 Be sure to provide for sufficient ven tilation in the work area 17 The pres...

Page 29: ...t 1x PCU LED 1x Accessory package The accessories consist of 3x Network cable 1x Operating instructions 1x Gas connection line kit including quick coupling and 2 hose clamps only for nitrogen option T...

Page 30: ...ts Overview Display Lid Input Button Rear view Control needle valve for nitrogen flushing Power supply connector socket USB connection Main switch Nitrogen connection for nitrogen variant of the PCU L...

Page 31: ...fferent options The second level is the process owner level where the process owner can per form different device configurations 1 Switching on the power plug at the back of the device brings you dire...

Page 32: ...fter switching on the device Welcome screen Selection of the material parameters If a parameter set is selected it will be highlighted on the display Additional confirma tion brings you to the selecte...

Page 33: ...4 Pressure mbar 5 Exposure icon ON OFF 6 Exposure atmosphere air vacuum nitrogen Ventilation of the exposure room Wait until the vacuum is released so that e g the sealing for the exposure chamber is...

Page 34: ...Configuration level in overview 1 Orientation line A vertically oriented narrow bar at the left and the right margin of the selected window is provided for guidance purposes Selection of the process p...

Page 35: ...rked air active 5 Exposure time Setting the LED intensities The intensity can be shown in percent per panel There are 3 LED spots on each panel Attention If the predetermined values are modified for t...

Page 36: ...the time stamp of the process recording which is shown inter alia in the final screen in the user level Factory setting When reverting back to the factory settings the individual parameter settings a...

Page 37: ...tly gas connection mains connection daily Cleaning of the device with a mild detergent weekly Maintenance unit Maintenance frequency Check whether the LED panels must be calibrated or changed weekly C...

Page 38: ...00 Exposure time place 1 and 2 minutes place 3 and 4 seconds 1 Vacuum ON 1 ON 0 OFF 0 Nitrogen OFF 1 ON 0 OFF Breakdown of the error codes in the final screen in the user level Code Status Background...

Page 39: ...hamber leaky Replacement of the lid sealing Hoses of the vacuum system leaky Replacement of the hoses Vacuum pump defective Exchange of the vacuum pump 03 LED do not work Lid not closed Close lid Lid...

Page 40: ...13 18 23 1 2 3 9 12 14 16 19 21 25 26 32 20 24 31 32 33 27 29 30 15 34 Posnr 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 24 25 26 27 28 29 30 31 32 33 34 35 6 D C B A E F G H 5 4 3 2 1 7...

Page 41: ...ame display cap 521057 15 cap for measuring feed through 521063 16 vacuum pump 521064KM32 17 UK power supply angled 51284 18 plate 521065 19 cable harness PCU LED with USB bushing 521066 20 angle piec...

Page 42: ...rmance of the device if the device is only used for the appro priate application purpose the operation is only carried out by professionally trained personnel the device is used in accordance with the...

Page 43: ...5 Warranty repair and maintenance work which have been incorrectly completed by the purchaser or third parties as well as in the case of the breaching of the seals All technical changes to the machine...

Page 44: ...Dreve Design Rev 050118 DUxxxxxx xx 1854 Dreve Firmengruppe Max Planck Stra e 31 59423 Unna Germany Tel 49 2303 8807 0 Fax 49 2303 82909 E Mail info dreve de www dreve com...

Reviews: