14. General information

Repair and maintenance work at the 

PCU LED N

2

 may only be performed by 

specialists. The power supply to the 

device must disconnected in any case.

The company Dreve will be responsi-

ble for the safety, reliability and perfor-

mance of the device, if

·  the device is only used for the appro-

priate application purpose.

·  the operation is only carried out by 

professionally trained personnel.

·  the device is used in accordance with 

these operating instructions.

·  extensions, new settings, changes or 

repairs are only performed by autho-

rised persons.

Since we at Dreve are constantly wor-

king on the further development of our 

products, we cannot exclude the possi-

bility of technical changes.

The manufacturer warranty is 2 years 

from date of delivery. The warranty right 

(liability of defects) is not limited by the 

warranty and is regulated in the gen-

eral terms and conditions of the com-

pany Dreve. The guarantee includes the 

assumption of repair and shipping costs 

in the case of material and manufactur-

ing defects. The warranty claims do not 

refer to natural wear nor to damages 

which are the result of the transfer of risk 

due to faulty or unintended use, exces-

sive loading, unsuitable equipment and 

any such chemical, electrochemical or 

electrical influences which are not pro-

vided in accordance with the contract. 

Warranty claims are excluded in the case 

of changes or repair and maintenance 

15. Warranty

work which have been incorrectly com-

pleted by the purchaser or third parties 

as well as in the case of the breaching 

of the seals.

All technical changes to the machine are 

prohibited and will result in the loss of 

the warranty claim. Repairs may only 

be performed by trained personnel of 

the company Dreve. For cases of repair, 

please contact the company Dreve,  

Max-Planck-Str. 31, 59423 Unna / Germany; 

Phone: +49 2303 8807-0.

After the sending-in of the product and 

the submission of the sales receipt, the 

product will be repaired free of charge 

or replaced by a comparable product.

16. Decommissioning of the product

The DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE 

COUNCIL of 4 July 2012 on waste electrical and electronic equipment (WEEE) 

lays down measures to protect the environment and human health. Waste 

electrical and electronic equipment marked as such may not be disposed 

of as unsorted municipal waste within the European Union. For detailed 

information regarding the professional disposal of WEEE please contact 

Dreve or your distributor.

Summary of Contents for PCU LED N2

Page 1: ...hnology Dreve Firmengruppe Max Planck Stra e 31 59423 Unna Germany deutsch english Lichtpolymerisationsger t f r den CAD CAM 3D Druck Prozess Light polymerization device for the CAD CAM 3D printing pr...

Page 2: ...mation on the use of the protective gas 29 7 Functional elements 30 8 Operation 31 9 Maintenance 37 10 Monitoring 38 11 Troubleshooting plan 38 12 Exploded view 40 13 Spare parts list 41 14 General in...

Page 3: ...s Mikrocontrol lers k nnen Strom Druck und Tem peratursensoren angesteuert und aus gelesen werden c Logging und Monitoring Die Informationen die von den Strom Druck und Temperatursensoren auf gezeichn...

Page 4: ...rom 16 A je Leiter IEC 61000 3 2 2014 Deutsche Fassung EN 61000 3 2 2014 EN 61000 3 3 2013 Elektromagnetische Vertr glichkeit EMV Teil 3 3 Grenzwerte Begren zung von Spannungs nderungen Spannungsschwa...

Page 5: ...23 Das Ger t nicht betreiben wenn das Geh use des Ger tes nicht geschlossen und verschraubt ist 24 Eigenm chtige Umbauten und Ver nderungen sind aus Sicherheitsgr nden unzul ssig Stellen Sie vor der I...

Page 6: ...lt in zwei Ebenen Die erste Ebene ist die Anwenderebene in der der Bediener verschiedene Optionen ausw hlen und best tigen kann Die zweite Ebene ist die Prozesseignerebene in dieser kann der Prozessei...

Page 7: ...n Parametersatz Statusfenster Durch nochmaliges Best tigen wird der Belichtungsprozess gestartet 1 Programmname 2 Returntaste 3 Belichtungsdauer 4 Druck mbar 5 Belichtungsicon ON OFF 6 Belichtungsatmo...

Page 8: ...f r das Anwenderlevel Einstellen der Prozessparame ter Dr cken des Drehknopfes 5 Sekunden 8 4 Bedienung Prozessebene Einstellen der Prozessparameter 1 Returntaste 2 Programmname frei definierbar durch...

Page 9: ...des Geh uses mit einem milden Reinigungsmittel w chentlich Wartungseinheit Wartungsh ufigkeit berpr fen ob die LED Panels gewechselt werden m ssen w chentlich mit Programm LED Test berpr fen ob die L...

Page 10: ...ziehen Abschaltung nach 150 Sekunden Deckeldichtung der Belichtungskammer undicht Erneuern der Deckeldichtung Schl uche des Vakuum systems undicht Erneuern der Schl uche Vakuumpumpe defekt Austauschen...

Page 11: ...33 51050 Steckverschraubung Legris 34 51079 3M BUMPON KLEBEFU SJ 5023 35 51283 Cordeset NEMA Netzstecker5 15 USA gerade ohne Abbildung 36 521092 Glasscheibe Nachh rteeinsatz PCU LED 37 521091 Rahmen N...

Page 12: ...n durch von ihr erm chtigte Personen ausge f hrt werden Da wir stetig an der Weiterentwicklung unserer Erzeugnisse arbeiten behalten wir uns technische nderungen vor Die Herstellergarantie betr gt 2 J...

Page 13: ...gging and Monitoring The information which is recorded by the current pressure and temperature sensors represents the used process parameters e g light on off vacuum on off nitrogen on off These proce...

Page 14: ...3 3 2013 Electromagnetic compatibility EMC Part 3 3 Limits Limitation of voltage changes voltage fluctuations and flicker in public low voltage supply systems for equipment with rated current 16 A per...

Page 15: ...ribed operating and main tenance conditions specified in these operating instructions must be com plied with Please observe the general accident prevention regulations when working with the PCU LED N2...

Page 16: ...form different device configurations 1 Switching on the power plug at the back of the device brings you directly to the user level 2 Switching on the power switch at the back of the device and the si...

Page 17: ...eter set in the status window Status window Additional confirmation starts the exposure process 1 Programme name 2 Return button 3 Exposure time 4 Pressure mbar 5 Exposure icon ON OFF 6 Exposure atmos...

Page 18: ...t activated for the user level Setting the process para meters press the rotary button 5 seconds 8 4 Operation Process level Setting the process parameters 1 Return button 2 Programme name freely defi...

Page 19: ...connection mains connection daily Cleaning of the device with a mild detergent weekly Maintenance unit Maintenance frequency Check whether the LED panels must be or changed weekly with program LED Tes...

Page 20: ...tch LED defective Exchange of the LED 04 No nitrogen flow Nitrogen valve at the gas cylinder not opened Warning The device is only o be operated with a maximum pressure of 5 bar 70 psi Open nitrogen v...

Page 21: ...521091 Rahmen Nachh rteeinsatz PCU LED 6 D C B A E F G H E A B C D F 5 4 3 2 1 7 8 9 10 11 12 1 2 3 4 5 6 7 8 DRV13078 Dreve ProDiMed GmbH Max Planck Str 31 D 59423 Unna Germany Tel Nr 02303 88 07 0 w...

Page 22: ...he transfer of risk due to faulty or unintended use exces sive loading unsuitable equipment and any such chemical electrochemical or electrical influences which are not pro vided in accordance with th...

Page 23: ...un microcontr leur l on peut exciter et lire les capteurs de courant de pression et de temp rature c Journalisation et suivi des para m tres de processus Les informations enregistr es par les capteurs...

Page 24: ...limites des courants harmoniques cou rant appel par les appareils 16 A 3 D claration de conformit CE EN ISO 12100 2010 rectification 1 de 12100 2011 03 DIN EN 60204 1 2006 A1 2009 rectification 1 zu D...

Page 25: ...Les Transformations et modifica tions arbitraires sont interdites pour des raisons de s curit Avant la mise en service assurez vous qu il n y a pas de dommages dus au transport V rifiez si le bo tier...

Page 26: ...vis en deux niveau le premier niveau est le niveau de l utilisateur o l op rateur peut s lectionner et confirmer diff rentes options Le second niveau est le niveau du propri taire des processus dans l...

Page 27: ...a m tres s lectionn Fen tre d tat Le processus d exposition est lanc par une confirmation r it r e 1 Nom du programme 2 Touche Retour 3 Dur e d exposition 4 Pression mbar 5 Symbole d exposition MARCHE...

Page 28: ...non activ pour le niveau de l utilisateur R glage des param tres de processus pression du bou ton tournant 5 secondes 8 4 Commande niveau des processus R glage des param tres de processus 1 Touche Ret...

Page 29: ...o tier avec un d tergent doux toutes les semaines Unit de maintenance Fr quence de mainte nance V rifier si les panneaux de LED doivent tre remplac s toutes les semaines avec le programme test LED V r...

Page 30: ...e de la chambre d exposi tion fuit Renouveler le joint d tanch it du couvercle Tuyaux du syst me du vide fuient Renouveler les tuyaux Pompe vide d fec tueuse Remplacer la pompe vide 03 Couvercle ouver...

Page 31: ...50937 Drosselventil 6 01 18 1N G1 8 31 51012 Dichtring aus Perbunan 32 51030 MECANYL ROHR RW LT 2A0031 S 33 51050 Steckverschraubung Legris 34 51079 3M BUMPON KLEBEFU SJ 5023 35 51283 Cordeset NEMA Ne...

Page 32: ...ons sont r alis s par des per sonnes autoris es par elles Dans la mesure o nous d veloppons nos produits en permanence nous nous r servons le droit d y apporter des modi fications techniques La garant...

Page 33: ...Dreve Design Rev 221119 D221119 200 1854 Dreve Firmengruppe Max Planck Stra e 31 59423 Unna Germany www dreve com...

Reviews: