![DressWall Freestanding Free 1-side Installation Manual Download Page 7](http://html1.mh-extra.com/html/dresswall/freestanding-free-1-side/freestanding-free-1-side_installation-manual_2530918007.webp)
D
WP alu pr
ofile = 2494 mm
D
WP alu pr
ofile = 2494 mm
D
WP alu pr
ofile = 2494 mm
D
WP alu pr
ofile = 2494 mm
D
WP alu pr
ofile = 2494 mm
D
WP alu pr
ofile = 2494 mm
A
WP
ADK = 3 mm
A
WP
ADK = 3 mm
2500 mm = H
DWP Profile length = shortest ceiling height - ( AWPADK x 2)
= 2500 - 6
= 2494 mm
Note that OPTION A is only possible for small floor/ceiling height variations
as you’ll need to use spacers to compensate for this difference.
All DWP profiles were ordered to 2492 mm ‘precut’ identical length in our
example.
If you also ordered ‘precut’ identical length , go directly to step 4.
OPTION A
-
all DWP profiles ordered to ‘precut’ length
spacer
Step 3: DWP Profile length
7
Summary of Contents for Freestanding Free 1-side
Page 1: ...DressWall Freestanding Free 1 side glass Free 1 side Free satellite Installation manual 1 ...
Page 20: ...AWPADK AWP DWP Secure the top end of the DWP profile in the same way 20 ...
Page 26: ...Installed back panels 26 ...
Page 51: ...Insert 6 square nuts in each drawer side board through the pre cut hole in 1 of the sides 51 ...