Model Specific Preparation
REQUIRED:
!
UNIDOOR MADRID Shower Door and Inline Panel Manual Ver 1 122019
5
©2019 DreamLine® All Rights Reserved
NOTE
1/2” Out-of-Plumb
Adjustment within
the u-channel; Verify
threshold and walls
with a level
Threshold must be
level
!
5/8”
minimum
flat threshold
±0.0
±0.0
±0.0
minimum
threshold
5/8”
Leave corner
protectors on the
glass until it is
necessary to
remove them!
!
2” X 6”
!
The PVC Hinge Spacers (#31) can be used to
compensate for a minor out-of-plumb condition
on the hinge-side wall up to 1/4” (6mm) and
should only be used behind ONE Hinge Assembly
(#05). Confirm the finished wall conditions with a
level before drilling any holes. Unnecessary use
of these spacers can compromise the fit of the
door. (see Page 11 for more information)
!
DO NOT attach the Handle/TowelBar
to the Glass until instructed.
DO NOT use the handle to lift the
glass during installation. This may
result in damage to the glass and/or
serious personal injury. Always use
an assistant and/or a
professional-grade glass suction cup
when handling heavy glass panels.
!
Professional installation and two installers recommended for this model
Contact the manufacturer of the base, tub
or threshold material with any questions
regarding the drilling of holes into their
product.
Tile
Acrylic
Tub
right-hand inline panel glass installation shown
panel glass
1/2” MAX
1/2”
Max
NOTE
up to 1/2” adjustment
for Out-of-Plumb
conditions within the
Vertical U-Channel (#09)
on the panel side only
The UNIDOOR MADRID is reversible for right- or left-swing door
installation. The left-swing door installation is shown as an
example throughout this manual. For the right-swing door
installation, simply begin on the opposite wall and reverse the
orientation of the steps shown.
TIP
L
Swing
Door
Door
R
Swing
R
Inline
Panel
L
Inline
Panel
The glass-to-wall hinges require
installation into a double stud
or 2x6 wood reinforcement.
(see page 3 for more information)