background image

         http://dreamcatcher.asia/cw 

 

 

 

 

 

 

 

 

 

 

        [email protected] 

 
ME1120 Mobile Communications 
 

 
 

Quick Start Guide - 17/24 

      

                     

                                                        

 
2. Support and Warranty 

 
 

2.1 

Terms and Conditions 

 
This courseware product contains scholarly and technical information and is protected by copyright 
laws and international treaties. No part of this publication may be reproduced by any means, be it 
transmitted, transcribed, photocopied, stored in a retrieval system, or translated into any language in 
any form, without the prior written permission of 

Acehub Vista Sdn. Bhd.

   

 
The use of the courseware product and all other products developed and/or distributed by 

Acehub 

Vista Sdn. Bhd.

 are subject to the applicable License Agreement.  

For further information, see the Courseware Product License Agreement. 

To retrieve the password for installation of the provided materials and software as well as the model 
answers and solutions for lab sheets, please register yourself at 

http://dreamcatcher.asia/cw

 under 

the Product Registration menu using the product key provided with the education courseware. 
 
 

2.2 

Product Warranty 

 

 

Acehub Vista Sdn. Bhd.

 warrants that its products sold will at the time of shipment be free 

from defects in material and workmanship and will conform to 

Acehub Vista Sdn. Bhd

.’s

 

applicable specifications. 

 

 

If 

Acehub Vista Sdn. Bhd.

 receives notice of a defect or non-conformance during the 

one 

year warranty

 period, 

Acehub Vista Sdn. Bhd.

 will, at its option, repair or replace the affected 

product. Buyer will pay shipping expenses for return of such product to 

Acehub Vista Sdn. 

Bhd.

 or its authorized reseller. 

Acehub Vista Sdn. Bhd.

 or its authorized reseller will pay 

expenses for shipment of the repaired or replacement product. 

 

 

This warranty shall not apply to any products 

Acehub Vista Sdn. Bhd.

 determines have been, 

by Buyer or otherwise, subject to operating and/or environmental conditions in excess of the 
maximum values established in applicable specifications, or have been subject to 
mishandling, misuse, neglect, improper testing, repair, alteration, damage, assembly, or 
processing that alters physical or electrical properties. 

 

 

In no event will 

Acehub Vista Sdn. Bhd.

 be liable for any incidental or consequential 

damages. 

 

 

This warranty extends to Buyer only and not to Buyer's customers or users of Buyer's 
products and is in lieu of all other warranties whether expressed, implied, or statutory 
including implied warranties of merchantability of fitness. 

 

 

For technical support and warranty, email 

[email protected]

 

Summary of Contents for ME1120

Page 1: ...ME1120 Mobile Communications Courseware Out of Box Teaching Solution for Mobile Communications Quick Start Guide version 2 02 Updated on 25 September 2018...

Page 2: ...Directive 73 23 EEC and the EMC Directive 89 336 EEC and carries the CE marking CAUTION ESD THIS PRODUCT CONTAINS ELECTRONIC COMPONENTS SENSITIVE TO ELECTROSTATIC DISCHARGE An electrostatic discharge...

Page 3: ...ware Customer Login Guide 5 1 Quick Setup and Verification 33522B Arbitrary Waveform Generator 7 2 Support and Warranty 17 Appendix A Digital RF Communications Training Kit 18 Appendix B Technical Spe...

Page 4: ...http dreamcatcher asia cw cw enquiry dreamcatcher asia ME1120 Mobile Communications Quick Start Guide 4 24...

Page 5: ...o login NOTE If you have created your DreamCatcher account before the 1 st of September 2017 you will receive an e mail request to reset your password If you do not receive the password reset e mail w...

Page 6: ...TER NEW PRODUCT Register a new product with the given product key NOTE Contact your local sales representative if you need further assistance C PRODUCTS DOWNLOADS Download the registered product s con...

Page 7: ...ying the IQ Modulated RF Signal in the Agilent 89601 VSA Software IMPORTANT Agilent VEE Runtime and Agilent 89601 VSA software are required to perform the following setup and verification It is assume...

Page 8: ...rnatively a USB to GPIB cable can also be used to connect the PC to function generator Launch the IQG software The IQ Signal Generator dialog box appears as shown on the right The GUI consists of thre...

Page 9: ...the I baseband data Click Next to enter the same USB GPIB address for Q baseband data ID 1 for the Q baseband data Click Save to save your settings and exit In the Waveform settings section set the fo...

Page 10: ...ers will be displayed The generated IQ waveform and its constellation are also displayed Observe the generated IQ waveform from both Channel 1 and Channel 2 of the oscilloscope Compare the measured IQ...

Page 11: ...ile Communications Quick Start Guide 11 24 Step 4 Powering Up the Training Kit Hardware Power up the Digital RF Communication training kit using an AC DC power adapter LED D1 green will light up when...

Page 12: ...MHz Filter Connect the Output Out of the Filter to the Input In of the 10 MHz Amplifier Then connect the Output Out of the Amplifier to Channel 1 of the oscilloscope Use a USB cable to connect a PC t...

Page 13: ...ility Options Rear Panel to open the rear panel menu Then press Ref Signal to display the reference signal mode menu Turn the Entry Knob to 10 MHz output and press Ref Signal To verify the DSO6000 ser...

Page 14: ...gure the instrument so that the VSA software can recognize it Go to Utilities Hardware Discovered Instruments You should see the oscilloscope connected on port USB in the Hardware window Select the os...

Page 15: ...In the Filter tab set the following parameters Measurement Filter Root Raised Cosine Reference Filter Raised Cosine and Alpha BT 0 5 Leave other settings as default Select MeasSetup Frequency Set the...

Page 16: ...rements can be performed using the Digital RF Communications training kit such as maximum output power measurement occupied bandwidth measurement ACPR measurement EVM measurement spurious and harmonic...

Page 17: ...shipment be free from defects in material and workmanship and will conform to Acehub Vista Sdn Bhd s applicable specifications If Acehub Vista Sdn Bhd receives notice of a defect or non conformance du...

Page 18: ...rating at 868 MHz The IQ modulator 10 MHz amplifier and 10 MHz bandpass filter can be connected in series to form a typical digital RF subsystem at baseband The 868 MHz amplifier and filter are essent...

Page 19: ...MHz Max power output 1 dB compression 5 20 dBm 10 MHz 3rd order intercept power IP3 14 10 dBm Two tones 10 1 MHz and 9 9 MHz VSWR 1 In Out 9 60 3 80 10 MHz 10 MHz Filter Min Typical Max Unit Remarks D...

Page 20: ...s Center frequency 901 MHz Bandwidth 439 MHz Stopband frequency Low High 794 1233 MHz Loss 3 dB Low High 725 1330 MHz Loss 10 dB Low High 650 1487 MHz Loss 20 dB Insertion loss 12 0 dB 868 MHz VSWR 1...

Page 21: ...0A 33250A FG U1035A IQ Signal Generator Software Data Pattern Baseband Filter Symbol Rate Max SPS Output Signal Function Generator Output 33220 33250 BPSK YES PRBS6 rc 0 5 1M 6 25 I and Q 1 0 QPSK YES...

Page 22: ...or DSO MSO without 10 MHz reference out signal 10 MHz In to 10 MHz Out and Common Trigger USB to USB connection PC running IQG software and 89601A VSA software Q Signal DSO6012A DSO7012A Oscilloscope...

Page 23: ...mcatcher asia cw cw enquiry dreamcatcher asia ME1120 Mobile Communications Quick Start Guide 23 24 Revision History Revisions Notes 2 01 Initial document 2 02 Added DreamCatcher Courseware Customer Lo...

Page 24: ...electronic mechanical photocopying recording or otherwise without prior written permission of Acehub Vista Sdn Bhd Every effort has been made to ensure that the information in this manual is accurate...

Reviews: