background image

 

 

PRODUCT ACCESSORIES 

 
 

The product is packed together with service instructions and list of servicing organisations. The heater is equipped 

with a safety valve as a protective element. The valve is mounted on the cold water supply (see chapter 7). The package 
contains anchors and fasteners to fix the heater. 

 

 
 

MESSAGE FOR CUSTOMERS 

 

 

The electric heater is designed for preparation of hot water in households, cottages and various welfare facilities. 

It allows installation of only one hot water consumption point. Its benefit is that it heats up water by power in an 
unlimited all-day time range.   The time of heating service water to the recommended temperature of 60°C is about 9 and 
18 minutes, depending on the volume.

 

Environment Type: 
 

It is recommended to use the product in an indoor environment with air temperatures from +2°C to 45°C and a 

max. relative humidity of 80%.

 

 
 

TECHNICAL DESCRIPTION 

 

 

The heater tank is steel enamelled for pressure connection, the electric heating element is copper. The heater tank 

consists of magnesium anode that helps protect the heater tank from corrosion. The heater tank is provided with a 
valuable polyurethane insulation, all is stored in an upper plastic container. Electric wiring is placed in the bottom (upper) 
part of the heater, under the removable guard of the heater.  Temperature of water can be set by a thermostat within the 
range between 5°C and 75°C, using the symbols on the thermostat selector button (read more in chapter 13). Cold water 
inflow is indicated with a blue ring, hot water outflow is indicated with a red ring. 

 

 
 

GENERAL TECHNICAL DATA 

 

 
 

OPERATING ACTIVITY 

 

              

After the heater is connected to electric network, the heating element starts heating water. The element is turned 

on and off by a thermostat.

 

              Thermostat can be set as per your need within the range from 5°C to 75°C. We recommend setting service water 
to max temperature of 55°C. This temperature ensures the optimal operation of the heater.  After reaching the temperature 
set, the thermostat switches off the electric circuit and discontinues water heating.  The control light signals if the element 
is in operation (light is on) or if it is off (the light goes out). In case of longer operation without using the heated volume 
the thermostat has to be set to position 9°C (set the “snowflake” symbol on the thermostat button) to avoid its freezing. 

 

 

WALL MOUNTING 

 

 

              

Prior to mounting check the loading capacity of the wall. If needed, reinforce it. Mount the water heater in vertical 

position  only.  The  fastening  screws  must  have  guaranteed  spacing  of  140  mm.  Mounting  dimensions  are  specified  on 
Fig.1.

 

 
 

Typ

TO 5 UP/IN

TO 10 UP/IN

TO 15 UP/IN

Capacity

l

5

10

15

Rated pressure

MPa

0,6

0,6

0,6

Weight 

kg

7

8

11

Power input

W

2000

2000

2000

Time of heating from 10°C to 60°C

min

9

18

27

Electric connection

V

1 PE-N 230V/50Hz

1 PE-N 230V/50Hz

1 PE-N 230V/50Hz

IP Protection

IP 24

IP 24

IP 24

Heat losses/energy efficiency class

kWh/24h

0,25 / G

0,33 / G

0,4 / G

Summary of Contents for TO 10 IN

Page 1: ...ELECTRIC WATER HEATER TO 5 IN UP TO 10 IN UP TO 15 IN UP Dru stevn z vody Dra ice stroj rna s r o Works Cooperative Dra ice Machine Plant Ltd Dra ice 69 29471 Ben tky nad Jizerou Tel 326 370 911 fax...

Page 2: ...es the right for engineering modification of the product The product is designed for permanent contact with drinkable water Guide Contents 1 PRODUCT ACCESSORIES 3 2 MESSAGE FOR CUSTOMERS 3 3 TECHNICAL...

Page 3: ...ween 5 C and 75 C using the symbols on the thermostat selector button read more in chapter 13 Cold water inflow is indicated with a blue ring hot water outflow is indicated with a red ring 4 GENERAL T...

Page 4: ...t water Safety valve is mounted on the cold water inlet identified with a blue ring Each hot service water pressure heater must have a safety valve with a membrane spring Nominal clearance of safety v...

Page 5: ...er and water main installation b open the hot water valve on the combination faucet c open the cold water inlet valve to the heater d As soon as the water starts running through the hot water valve th...

Page 6: ...t is on until the water in the heater heats up to the selected temperature or until switched off as scheduled Due to heating the volume of water increases which causes water dripping from the combinat...

Page 7: ...gainst electric shock SN 33 2000 5 51 Electric installations of buildings SN 33 2000 7 701 Low voltage electric installations Single purpose devices and devices in special premises Premises with tub o...

Page 8: ...8 Fig 2 Wiring scheme Explanation 1 Thermostat 2 Thermal fuse non reversible 3 Heating element 4 Operation indicator 5 Terminal board L Phase conductor N Null conductor Earth conductor 04 2012...