Read carefully the below instructions prior to the installation of the water heater.
INFORMATION LEAFLET
pursuant to Directive No. 442//2004 Coll., and Annex No.7
TO 5, 10, 15 UP – pressure heater of 5 (10, 15) l capacity located above the supply point
TO 5, 10, 15 IN – pressure heater of 5 (10, 15) l capacity located below the supply point
Dear Customer,
The Works Cooperative of Dražice – Machine Plant, Ltd., would like to thank you for your decision to use a product of
our brand.
With this guide, we will introduce you to the use, construction, maintenance and other information.
Product’s reliability and safety is proven by tests implemented by the Engineering Test Institute in Brno.
The manufacturer reserves the right for engineering modification of the product.
The product is designed for permanent contact with drinkable water.
Guide Contents
1
PRODUCT ACCESSORIES ........................................................................................................................................................3
2
MESSAGE FOR CUSTOMERS ..................................................................................................................................................3
3
TECHNICAL DESCRIPTION .....................................................................................................................................................3
4
GENERAL TECHNICAL DATA ................................................................................................................................................3
5
OPERATING ACTIVITY ...........................................................................................................................................................3
6
WALL MOUNTING ...................................................................................................................................................................3
7
PLUMBING FIXTURE ...............................................................................................................................................................4
8
ELECTRICAL INSTALLATION ................................................................................................................................................5
9
PUTTING THE HEATER INTO OPERATION ..........................................................................................................................5
10
IMPORTANT NOTICES .............................................................................................................................................................5
11.
FUNCTIONAL DEFECTS ..........................................................................................................................................................6
12.
FIRE-FIGHTING REGULATIONS FOR INSTALLATION AND USE OF HEATER ................................................................6
13.
USE AND MAINTENANCE OF HEATER .................................................................................................................................6
14.
INSTALLATION REGULATIONS.............................................................................................................................................7
Tank-type water heaters – suspended, vertical
TO 5 UP/IN
G
50
5
9
0,3
0,25
TO 10 UP/IN
G
33
10
18
0,6
0,33
TO 15 UP/IN
G
29
15
27
0,9
0,44
Time of
content
heating
(min)
Electricity
consumption
for heating of
the contents
from 10°C to
60°C in kWh
Heat losses
kWh/24hr
Heater types
Energy
efficiency
class
Heat
losses
Wh/24hr/l
Nominal
capacity
(l)