background image

 

 

e-mail:[email protected]

 

Read carefully the below instructions prior to the installation of the heater! 

 
Dear Customer, 

The Works Cooperative of Dražice – Machine Plant, Ltd., would like to thank you for your decision to use a product 
of our brand. 

 

With this guide, we will introduce you to the use, construction, maintenance and other information on indirect water 
heaters. 
Product’s reliability and safety is proven by tests implemented by the Engineering Test Institute in Brno.

 

 

The manufacturer reserves the right for engineering modification of the product. 
The product is designed for permanent contact with drinkable water.

 

 

 
 
 
 
 
Guide Contents 
 

1.  Function description: ................................................................................................................................. 2 

1.1 

Hot water consumption ...................................................................................................................... 2 

1.2 

Energy saving..................................................................................................................................... 3 

1.3 

Emergency power consumption ......................................................................................................... 3 

2.  Servicing .................................................................................................................................................... 3 

2.1 

The service devices of the heater are located under the plastic guard of the control panel. .............. 3 

2.2 

Temperature setting ........................................................................................................................... 3 

2.3 

Limiting the regulation range; locked settings. .................................................................................. 3 

3.  Structure of the heater ................................................................................................................................ 4 
4.  Operating conditions .................................................................................................................................. 4 

4.1 

General ............................................................................................................................................... 4 

5.  Wall mounting ........................................................................................................................................... 5 

5.1 

Connection to power water ................................................................................................................ 5 

6.   First putting into operation........................................................................................................................ 7 

6.1 

Putting out of service, discharge ........................................................................................................ 7 

7.  Inspection, maintenance & care for the appliance ..................................................................................... 7 
8.  Most frequent function failures and their causes ....................................................................................... 8 
9.  Installation regulations ............................................................................................................................... 8 

 
 

 

 

Environment Type: 

 

It is recommended to use the product in indoor environment with air temperatures from +2°C to 45°C and a 

relative humidity up to 80%. 
 

1. 

Function description: 

 
The  heater  is  designed  for  accumulation  heating  of  service  water  using  electricity.  Water  is  heated  by  an  electric 
element in an enamelled thermally insulated tank at the time defined by the power supplier. The element is at the time 
of heating controlled by a thermostat the temperature of which can be adjusted continuously (within the range between 
5°C and 74°C). Once the selected temperature is reached, heating interrupts automatically. Water accumulated in the 
tank is then used for consumption. 

 

1.1

 

Hot water consumption 

 

Consumption  of  hot  water  in  households  depends  on  the  number  of  people,  amount  of  sanitary  equipment,  length, 
diameter  and  insulation  of piping  in  the  flat,  or on  individual  habits  of  users.  The  cheapest  option  of  water  heating 
comes  at  the  time  when  the  electricity  rate  is  reduced.    Find  out  in  what  time  intervals  your  electricity  supplier 
provides reduced tariff and, depending on that information, select relevant volume and power input of the heater so 
that your hot water consumption covered the needs of your household.

 

Summary of Contents for OKHE 100

Page 1: ...EATERS FOR VERTICAL MOUNTING Electric water heaters OKHE 80 OKHE 100 OKHE 125 OKHE 160 Družstevní závody Dražice strojírna s r o Works Cooperative Dražice Machine Plant Ltd Dražice 69 29471 Benátky nad Jizerou Tel 326 370 911 Fax 326 370 980 www dzd cz ...

Page 2: ...intenance care for the appliance 7 8 Most frequent function failures and their causes 8 9 Installation regulations 8 Environment Type It is recommended to use the product in indoor environment with air temperatures from 2 C to 45 C and a relative humidity up to 80 1 Function description The heater is designed for accumulation heating of service water using electricity Water is heated by an electri...

Page 3: ...c guard 2 2 Temperature setting Water temperature is set by turning the thermostat knob The desired symbol is adjusted against the fixed point on the control panel Notice Adjusting the thermostat selector at the left backstop does not mean permanent shutoff of the heating element When the heater is in use without blocking the daily rate we do not recommend the temperature to be set above 65 C The ...

Page 4: ...ment well 7 thermowell 3 ceramic heating element 2000W 8 hot water withdrawal pipe 4 operation thermostat with external control 9 Mg anode and safety thermostat 10 enamelled steel receptacle 5 electric installation guard 11 polyurethane insulation 6 cold water filling pipe 12 heater shell 4 Operating conditions 4 1 General The tank shall only be used in accordance with the conditions specified on ...

Page 5: ...e service water inlets and outlets must be provided with screw coupling Js 3 4 Safety valve is mounted on the cold water inlet identified with a blue ring Each hot service water pressure heater must have a membrane spring loaded with a safety valve Nominal clearance of safety valves is defined in the ČSN 0 60830 standard The heaters are not equipped with a safety valve The safety valve must be eas...

Page 6: ...tition corresponding with the input wire diameter of 8 or 10 Heater is connected to power supply 1 PEN AC 230V 50Hz via a fixed movable wire The circuit must contain a breaker disconnecting all poles of the network and a circuit breaker protector Installations in bathrooms lavatories and showers must comply with the ČSN33 2000 7 701 standard To adjust the distance from the wall connect the wire of...

Page 7: ...ot water heater is put out of service for a longer time or if it is not going to be used it has to be drained and disconnected from the electric supply network on all poles The switch for the supply lead or the fuse cut outs have to be shut off At places with permanent risk of frost the hot water heater must be drained before the cold season starts if the appliance remains out of service for sever...

Page 8: ...stat failure Safety thermostat shut off probably due to failed operation thermostat Water is not warm enough LED is on Failure of one of the coils in the element 2x 1000W Temperature of water is not corresponding with the temperature on the control Defective thermostat Water is constantly dripping off the safety valve LED is not on Input pressure too high faulty safety valve Do not try to repair t...

Page 9: ...elivered The service fee was paid pursuant to Act No 477 2001 Coll as amended at EKO KOM a s The client number of the company is F06020274 Take the water boiler packages to a waste disposal place determined by the town When the operation terminates disassemble and transport the discarded and unserviceable heater to a waste recycling centre collecting yard or contact the manufacturer 05 2012 ...

Reviews: