2

 

OPERATION AND FITTING INSTRUCTIONS 

2.1

 

OPERATING CONDITIONS 

 

The tank shall only be used in accordance with the conditions specified on the power plate 
and in instructions for

 

electric wiring.

  

Besides the legally acknowledged national regulations 

and standards, also conditions for connection defined in the local electric and water works 
have to be adhered to, as well as the installation and operation manual.

 

The  temperature  at

 

the  place  of  the  tank  installation  must  be  higher  than  +2°C;  and  the 

room must not freeze.

 

The appliance has to be mounted at a convenient place; it means that 

the  appliance  must  be  easily  available  for  potential  necessary  maintenance,  repair  or 
replacement, as the case may be.

  

 

If water is strongly calcareous we recommend that any of the common decalcifying devices 
was installed with the appliance, or that the thermostat was set to the minimum operating 
temperature of 60

o

C  (setting  to  position “ECO“).

 

For  proper operation,  drinkable  water  of 

adequate quality shall be used.

 

To avoid potential sediments we recommend that the device 

was installed together with a water filter.

 

 

2.2

 

ELECTRICAL INSTALLATION 

2.2.1

 

ELECTRIC INSTALLATION FOR

:

 

OKCE 100 S/2.2 KW; OKCE 125 S/2.2 KW;

 

The wiring diagram is attached to the tank on the side of the electric installation guard.

 

Connection,  repairs,  and  wiring  inspections  may  only  be  carried  out  by  a  company  authorised  to  such 

activity.

 

Expert connection must be confirmed on the warranty certificate.

 

The tank is connected to the 230 V/50 Hz electrical network using a fixed moving conductor with a switch 

that  turns  off  all  network poles  and  the  circuit  breaker  (protector).

 

The  degree  of  protection  of  electric 

parts of the heater is IP 44.

 

Wiring diagram:  

 

 

 

 

 

 

 

 

 

 

Figure 2 

Summary of Contents for Okce 100

Page 1: ...MANUAL STATIONARY ELECTRICAL HOT WATER TANKS OKCE 100 NTR 2 2 kW OKCE 125 NTR 2 2 kW Dru stevn z vody Dra ice stroj rna s r o Dra ice 69 294 71 Ben tky nad Jizerou Phone 420 326 370 990 Fax 420 326 37...

Page 2: ...kW 7 2 3 PLUMBING FIXTURE 8 2 4 PRESSURE LOSSES 9 2 5 CONNECTION OF INDIRECT TANK TO HOT WATER SYSTEM 9 2 6 EXAMPLES OF tankS CONNECTION 10 2 7 FIRST COMMISSIONING 12 2 8 CLEANING OF TANK AND EXCHANG...

Page 3: ...would like to thank you for your decision to use a product of our brand With this guide we will introduce you to the use construction maintenance and other information on electrical water heaters The...

Page 4: ...tube and as a unit it is entirely coated with hot water resistant enamel A flange is welded onto the upper bottom of the receptacle with a flange lid screwed to it A sealing ring is inserted between t...

Page 5: ...524 E 195 195 F 635 765 L 535 635 Typ OKCE 100 NTR 2 2 kW OKCE 125 NTR 2 2 kW 1 3 DESIGN AND BASIC DIMENSIONS OF TANK OKCE 100 NTR 2 2 kW OKCE 125 NTR 2 2 kW Figure 1 1 outer 3 4 inner 3 4 outer 1 2...

Page 6: ...RE OF HOT WATER C 80 Heating surface of bottom heat exchanger m2 1 1 45 BOTTOM HEAT EXCHANGER POWER AT HEATING WATER TEMPERATURE OF 80 AND FLOW OF 720 l h kW 24 32 PERMANENT HOT WATER POWER l h 610 99...

Page 7: ...f the common decalcifying devices was installed with the appliance or that the thermostat was set to the minimum operating temperature of 60o C setting to position ECO For proper operation drinkable w...

Page 8: ...ed between the tank and the safety valve During assembly follow the guide provided by the safety equipment manufacturer It is necessary to check the safety valve each time before putting it into opera...

Page 9: ...heating by electric energy When the tank is connected to power supply the heating element heats water The element is turned on and off by a thermostat After reaching the temperature set the thermosta...

Page 10: ...n the floor next to the heating source or in its proximity The heating circuit shall be connected to marked tank exchanger inputs and outputs and bleeder valve installed at the highest point It is nec...

Page 11: ...ample of group connection of tanks by Tichellman method for equal HSW withdrawal of from all tanks OV Heating water TUV Hot service water SV Cold water 1 Return valve C Circulation 2 Pump Figure 3 Fig...

Page 12: ...heating system turn off electricity an open the valves on the heating water inlet and outlet possibly de aerate the exchanger i once the operation restarts keep flushing the tank until the cloud disap...

Page 13: ...for the thermostat control lights with wires temperature indicator set of M12 or M10 bolts heating element When ordering spare parts give part name type and type number from the heater label 3 OPERAT...

Page 14: ...er is cold Light off Thermostat failure The safety thermostat shut off the power supply Electric supply outside the heater interrupted Temperature of water is not corresponding with the temperature se...

Page 15: ...s of the flange joint of the tank It is not allowed to handle the thermostat aside from temperature resetting with a control button All electric installation handling setting and regulation feature ex...

Page 16: ...livered The service fee was paid pursuant to Act No 477 2001 Coll as amended at EKO KOM a s The client number of the company is F06020274 Take the water boiler packages to a waste disposal place deter...

Reviews: