OPERATION AND FITTING INSTRUCTIONS
2.1
OPERATING CONDITIONS
The tank shall only be used in accordance with the conditions specified on the power plate
and in instructions for
electric wiring.
Besides the legally acknowledged national regulations
and standards, also conditions for connection defined in the local electric and water works
have to be adhered to, as well as the installation and operation manual.
The temperature at
the place of the tank installation must be higher than +2°C; and the
room must not freeze.
The appliance has to be mounted at a convenient place; it means that
the appliance must be easily available for potential necessary maintenance, repair or
replacement, as the case may be.
If water is strongly calcareous we recommend that any of the common decalcifying devices
was installed with the appliance, or that the thermostat was set to the minimum operating
temperature of 60
o
C (setting to position “ECO“).
For proper operation, drinkable water of
adequate quality shall be used.
To avoid potential sediments we recommend that the device
was installed together with a water filter.
2.2
ELECTRICAL INSTALLATION
2.2.1
ELECTRIC INSTALLATION FOR
:
OKCE 100 S/2.2 KW; OKCE 125 S/2.2 KW;
The wiring diagram is attached to the tank on the side of the electric installation guard.
Connection, repairs, and wiring inspections may only be carried out by a company authorised to such
activity.
Expert connection must be confirmed on the warranty certificate.
The tank is connected to the 230 V/50 Hz electrical network using a fixed moving conductor with a switch
that turns off all network poles and the circuit breaker (protector).
The degree of protection of electric
parts of the heater is IP 44.
Wiring diagram:
Figure 2