14
-
Figure 6
Adjusting the thermostat knob to the left backstop does not mean permanent shutoff of the
heating
element.
When the heater is in use without blocking the daily rate, we do not recommend the
temperature to be set above 65
℃
. Select the "
ECO
“ symbol as the maximum.
3.2
MOST FREQUENT FUNCTION FAILURES AND THEIR CAUSES
FAILURE SYMPTOM
INDICATOR
SOLUTION
Water is cold
•
Light on
•
Heating element failure
Water is not warm
enough
•
Light on
•
failure of one of the heating
coils in the element
Water is cold
•
Light off
•
Thermostat failure
•
The safety thermostat shut
off the power supply.
•
Electric supply outside the
heater interrupted
Temperature of water is
not corresponding with
the temperature set on
the control
•
Light on
•
Thermostat failure
Table 3
Do not attempt to repair the failure yourselves.
Seek either expert or service help.
It does
not take much for an expert to remove the defect.
When organizing repair state the model
designation and serial number that is to be found on the power plate of your water tank.
lower limit of temp. scope
(around 5°C)
fixed point on the control
panel
"anti
-
freezing" temperature
(about 8°C)
upper temperature range
limit (about 74
℃
)
"ideal" temperature (about
55
℃
)