15
-
2.4
ELECTRICAL INSTALLATION
2.4.1
GENERAL INFORMATION FOR ELECTRICAL INSTALLATION
Perform the connection according to the scheme. Factory connection must not be changed! (Figure
12).
In the electric wiring casing remove the partition corresponding with the input wire diameter of Ø8 or Ø10
(
Figure
11). The degree of protection of electric parts of the heater is IP 44. Power input of electric element
is 2200 W.
Figure 11
It is necessary to observe the below requirements during the electric wiring.
•
The wiring diagram is attached to the heater on the electrical installation guard (see
Figure 12).
•
The electrical installation shall only be connected, repaired and inspected by a person
authorised to perform that activity.
•
Expert connection must be confirmed on the warranty certificate.
•
The heater is connected to the 230 V/50 Hz electricity supply using a fixed moving conductor
with a switch that turns off all network poles and the circuit breaker (protector).
•
In the OKC 80
-
125 and OKC 100
-
125/1m
2
heaters, after wall mounting and adjusting
the distance from the wall by M8x80 rectifying screw, connect the external protective
connection wire to the rectifying screw.
•
In the OKC 160
-
200 and OKC 160
-
200/1m
2
heaters, after wall mounting, connect
the external protective connection wire to the bottom hinge to the earth screw.
•
Installations in bathrooms, laundry rooms, rest rooms and showers, must be in compliance
with standard.
•
The degree of protection of electric parts of the heater is IP 44.
•
Adhere to the protection against electric shock injury according to standard.
Ø10
Ø8
Ø8
Ø10