10
-
Table 3
TYPE
OKC 80
OKC 100
OKC 100/1 m
2
OKC 125
OKC 125/1 m
2
OKC 160
OKC 160/1 m
2
OKC 200
OKC 200/1 m
2
VOLUME
L
75
95
120
147
195
MAX OPERATING
OVERPRESSURE IN THE TANK
MPa
0.6
MAX MAXIMUM OPERATING
OVERPRESSURE IN THE
EXCHANGER*
MPa
1
ELECTRICAL CONNECTION
V
1 PE
-N ~
230V/50Hz
INPUT
W
2200
EL. PROTECTION
IP 44
MAX TEMPERATURE OF HOT
WATER
°C
80
MAX OPERATING
TEMPERATURE IN THE
EXCHANGER
°C
110
RECOMMENDED
TEMPERATURE OF HOT WATER
°C
60
HEIGHT OF THE HEATER
mm
757
902
1067
1255
1290
DIAMETER OF THE HEATER
mm
524
524
524
524
584
MAX WEIGHT OF THE HEATER
WITHOUT WATER
kg
40
50/57
55/64
62/71
79/85
TIME OF EL. HEATING FROM
10°C TO 60°C*
hrs
2.0
2.5
3.2
3.9
5.2
TYPE
OKC 80
OKC 100
OKC 125
OKC 160
OKC 200
EXCHANGER HEAT TRANSFER
SURFACE
m
2
0.41
0.68
0.68
0.68
0.68
HEATING TIME BY EXCHANGER
FROM 10°C TO 60°C AT FLOW
720 l/h
min
32
23
28
35
45
RATED THERMAL OUTPUT AT
HEATING WATER
TEMPERATURE 80°C AND
FLOW 310 l/h
W
6000
9000
9000
9000
9000
HEATING TIME BY EXCHANGER
FROM 10°C TO 60°C AT FLOW
310 l/h
min
50
48
55
67
86
LOAD PROFILE
M
M
M
L
XL
DAILY ELECTRICITY
CONSUMPTION
kWh
6.19
6.31
6.59
12.03
20.34
MIXED WATER V40
L
138.7
165.41
231.1
242.83
331.26
TYPE
OKC 100/1m
2
OKC 125/1m
2
OKC 160/1m
2
OKC 200/1m
2
EXCHANGER HEAT TRANSFER
SURFACE
m
2
-
1.08
1.08
1.08
1.08
RATED OUTPUT AT HEATING
WATER TEMPERATURE OF
80°C AND FLOW 720 L/H
W
-
24000
24000
24000
24000
HEATING TIME BY EXCHANGER
FROM 10°C TO 60°C
min
-
14
17
21
28
STATIC LOSS
W
-
47
57
67
72