What is a programmer?
...an explanation for householders
Programmers allow you to set ‘On’ and ‘Off’ time periods.
Some models switch the central heating and domestic hot
water on and off at the same time, while others allow the
domestic hot water and heating to come on and go off at
different times.
Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle.
On some programmers you must also set whether you want
the heating and hot water to run continuously, run under the
chosen ‘On’ and ‘Off’ heating periods, or be permanently off.
The time on the programmer must be correct. Some types
have to be adjusted in spring and autumn at the changes
between Greenwich Mean Time and British Summer Time.
You may be able to temporarily adjust the heating pro-
gramme, for example, ‘Override’, ‘Advance’ or ‘Boost’. These
are explained in the manufacturer’s instructions.
The heating will not work if the room thermostat has switched
the heating off. And, if you have a hot-water cylinder, the
water heating will not work if the cylinder thermostat detects
that the hot water has reached the correct temperature.
INSTALLATION MUST ONLY BE
CARRIED OUT BY A QUALIFIED ELECTRICIAN OR
HEATING ENGINEER.
MAKE SURE MAINS INPUT HAS A 3 AMP FUSE.
Drayton
Tempus 1, 2 (new models)
N
L
1
2
3
4
Drayton Lifestyle
LP111, LP711, LP111Si, LP711Si
N
L
1
2
3
4
Switchmaster
300
N
L
4
1
ACL
TC (Towerchron)
2
1
4
7
Drayton
Tempus 1, 2 (old models)
N
L
1
2
3
4
Switchmaster
980
N
L
4
1
Danfoss Randall
TS15, 75 (Mk18)
E
N
L
1
4
2 5/6
Danfoss Randall
TS715, TS715Si
N
L
1
4
2
3
Danfoss Randall
TS975
E
N
L
5
4
6 1,2,3
Danfoss Randall
SET1, SET1E
E
N
L
5
4
6
Danfoss Randall
SET4
E
N
L
5
4
6
Danfoss Randall
103, 103E, 103E5, 103E7
4
5
6
3
1
2
Danfoss Randall
911, 971
E
N
L
5
6
4
2
Grasslin Towerchron
QE1
N
L
2
4
Grasslin Towerchron
T2001, T2001Q
E
N
L
7
Honeywell
ST 6100A, ST 6100C
N
L
1
4
2
Honeywell
ST 7000B
Horstmann
Centaur SC1, SC7
L
Horstmann
Centaur Plus, C11, C17, C17-ZW
N
L
2
4
3
Horstmann
Emerald 423, Pearl Auto
N
L
2
4
Horstmann
517, Coronet, H11, H17
E
N
L
3
4
Landis & Staefa
RWB3
N
L
4
3
Landis & Staefa
RWB30, RWB50, 100, 152, 170
N
L
4
4
3
Landis & Staefa
RWB7
Potterton Myson
EP4000, 4001, 4002, 5002
N
L
5
4
2
Sangamo
M6
Smiths
Centroller Mk1, Mk2
N
L
3
2
Smiths
Centroller 30
1
2
3/4
Smiths
Centroller 300, 980
N
L
4
1
Sunvic
Select 107, SunProl1000
N
L
1
3
2
4
Sunvic
SP20, SP35
N
L
3
5
4
5
Venner
Vennerette
N
L
LINE
LOAD
DUAL
CHANNEL
LP241Si, LP522Si, LP722Si
DUAL
CHANNEL
Programmer
hot water
TIMESWITCH TERMINAL COMPARISONS
Earth
Neutral
Live
Common
On
Off
Spare
MAKE
MODEL
PROGRAMMER TERMINAL COMPARISONS
Current Models
Earth
Neutral
Live
Ch1 on
Chl2 on
Ch3 on
Ch4 on
Lifestyle
SINGLE
CHANNEL
for heating
LP111Si, LP711Si
SINGLE
CHANNEL
Timeswitch
Installer note: After installation, tear along perforations indicated and retain this section - only leave
the User instructions with the end user
Installer note: After installation, tear along perforations indicated and retain this section - only leave
the User instructions with the end user
E
4
6
3
1
Salus
EP101, SP120
4
3
N
L
Myson
Myson
N
L
1
3
2
4
MEPIC
4
Mictrotimer (link L-5 and 5-8)
E
N
L
5
6
E
N
L
4
2
3
3
3
2
N
L
1
2
3
4
British Gas
EMT2, UT1, UT2
N
L
1
3
2
4
Drayton
Drayton
Drayton
N
L
1
2
3
4
N
L
1
2
3
4
N
L
1
2
3
4
SM1
miGenie Wish 1
MiTimeMT711R, MiTime RF Pack1
Current Models
Discontinued/Competitors’ Models