background image

15

to switch it on (ADV will be displayed), and it will

stay on until the end of the next period. Or if the heating/hot
water is on and you don’t need it, press Advance and it will go
off until the beginning of the next ON period.

Advance will only operate in TIMED or ONCE modes.

2. Press & Hold

to switch on for an extra hour ( & BST will

be displayed), then Press again for two ( ) or three ( ) hours.
To cancel Boost, Press Boost again ( ). Or if the heating/hot
water is already on, using Boost will extend the ON time by one,
two or three hours.

User’s Instructions

PROGRAMMERS

Press YES and alter ON1, OFF1, ON2, OFF2, ON3 and OFF3

times in the same way.

Set each day

If, after you’ve set OFF3 for both SAT & SUN, you want to fine-

tune Saturday or Sunday, press SET? until you find the first day
you want to adjust – then go through the procedure, altering any
time you wish. Press SET? to move on to the next day. When
you press SET? after setting your hot water for Sundays, the pro-
grammer will go back to normal operation.

If you don’t want to alter either day, keep pressing SET?

until the programmer goes back to normal operation.

If the engineer has set your program and timings – you
won’t need to do anything else. Just keep this guide in a
safe place for future reference.

INTRODUCTION

Lifestyle Programmers will automatically switch your central
heating and hot water on and off at times that suit you.
Depending on your system, central heating and hot water
can either both come on and off at the same time, or work
independently. The light on the front of the programmer
shows when each one is on.

SAT

LP711Si – a 7-day program, allowing for different timings on
each day of the week, up to 3 heating periods each day.

Want to leave a timing as it is? Just press SET? and move on
to the next one.
If you need to reset your timings to the standard program and
start again, press ‘SET’ and ‘+’ together to go back to the
pre-set program.

Your system will come on for up to 3 heating periods every
24hrs. ON1 starts the first one, OFF1 finishes it, and so on.
Notice that ON2 and OFF2 are set to the same time.* This
means your system won’t respond, but if you want to activate
that middle period or change any other timings – read on.

When you press SET? after setting OFF3, the timeswitch will

return to normal operation.

Press the YES button, and you’ll see ON1, the start of your first

heating period. Adjust it in 1-minute steps using the – and +
buttons. If the – and + buttons are held down, the time changes
in 10-minute steps.

Press SET?, and you’ll see OFF1, the end of your first heating

period. Adjust this in the same way, press SET? then repeat the
procedure for ON2, OFF2, ON3 andOFF3

Over-riding the program

LP241Si – a 24hr program, with central heating and hot water

working independently for up to 3 heating periods each day,

and every day the same.
If the timings haven’t been set for you, then your programmer

will still be on the factory-set standard 24hr program, with

central heating and hot water operating together on the

same timings for every day of the week. But it’s easy to make

changes, and have heating and water working independently

– just follow the instructions.
Want to leave a timing as it is? Press SET? and move on to

the next one.
If you need to reset your timings to the standard program

and start again, press ‘SET’ and ‘+’ together to go back to

the pre-set program.
If you don’t press anything for two minutes, the programmer

automatically goes back to normal operation.

THE LP241Si 24hr ELECTRONIC PROGRAMMER

OFF
TIMED
ONCE

ON

= continuously on.

On each side of the display there are four operating modes –
one group for central heating, the other for hot water. You can
change modes with immediate effect by using the appropriate
SELECT button. This won’t alter the timings in your program,
which you can return to by selecting TIMED.

on the programmer, found under the bottom flap.

Summary of Contents for Lifestyle LP111Si

Page 1: ... LP241Si LP522Si LP722Si SINGLE CHANNEL SINGLE CHANNEL Timeswitch DUAL CHANNEL Programmer for heating OR hot water LP111Si LP711Si Technical Helpline 0333 7000622 Email customer care draytoncontrols co uk Web www draytoncontrols co uk SERVICE INTERVAL for heating AND hot water Installation Instructions 06490050001 ISS F TIMESW MAKE Lifestyle the User instructions with the end user Salus Myson Myso...

Page 2: ...s preserved Programming resolution 1 minute Wiring Fixed wiring only to comply with current IEE regulations Maintenance Must be maintained by a qualified electrician or heating engineer Drayton Drayton Lifestyle Switchmaster Switchmaster ACL ACL Danfoss Randall Danfoss Randall Danfoss Randall Danfoss Randall Danfoss Randall Danfoss Randall Danfoss Randall Danfoss Randall Grasslin Towerch Honeywell...

Page 3: ...e terminals and if necessary change the wiring of the wall plate to suit Now plug the Lifestyle unit into the wall plate and tighten the securing screws Check the 3A fuse and switch on the mains FITTING A NEW WALL PLATE The ideal location is 1 4m above floor level with reasonable lighting good access no condensation no extremes of temperature and a supporting surface that fully covers the back of ...

Page 4: ...Pearl Auto N L 2 4 Horstmann 517 Coronet H11 H17 E N L 3 4 Landis Staefa RWB3 N L 4 3 Landis Staefa RWB30 RWB50 100 152 170 N L 4 4 3 Landis Staefa RWB7 Potterton Myson EP4000 4001 4002 5002 N L 5 4 2 Sangamo M6 Smiths Centroller Mk1 Mk2 N L 3 2 Smiths Centroller 30 1 2 3 4 Smiths Centroller 300 980 N L 4 1 Sunvic Select 107 SunProl1000 N L 1 3 2 4 Sunvic SP20 SP35 N L 3 5 4 5 Venner Vennerette N ...

Page 5: ...l ST 699 799 link L 5 and 5 8 N L 7 4 6 3 Honeywell ST 6200 ST 6300 ST 6400 ST 6450 N L 1 2 3 4 Honeywell ST 7100 link L 3 and 3 6 N L 7 4 8 5 Horstmann 525 527 425 Diadem H21 H27 E N L 3 6 1 4 H121 Tiara link L 2 and 2 5 Landis Staefa RWB2 RWB2E 20 40 102 200 N L 1 2 3 4 252 270 RWB9 Myson Microtimer link L 5 and 5 8 N L 7 4 6 3 Potterton Myson All EP2000 s EP3000 s EP6000 s N L 1 2 3 4 link L 5 ...

Page 6: ...erminal L or from a separate supply with a 3A fuse WIRING THE PROGRAMMER Arrowed numbers relate to the junction box Consult boiler handbook for details of pump overrun wiring Connection Charts Wiring Colour Codes GR Grey Y Yellow BK Black BL Blue BR Brown RD Red W White OR Orange YG Yellow Green C Common H Call for Heat S Satisfied N Neutral E Earth L Live Thermostat Key USING A DRAYTON SIMP L FIT...

Page 7: ...2 Email customer care draytoncontrols co uk Web www draytoncontrols co uk for heating AND hot water User s Instructions 06490050001 ISS F SINGLE CHANNEL Timeswitch DUAL CHANNEL Programmer SERVICE INTERVAL Lifestyle If the engine need to do for future re Sometimes system tem Here s how program Switching o On the front It allows you the program you can eith 1 Press Adva stay on unti you don t ne beg...

Page 8: ...ing periods or be permanently off The time on the programmer must be correct Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time You may be able to temporarily adjust the heating pro gramme for example Override Advance or Boost These are explained in the manufacturer s instructions The heating will not work if the room thermostat h...

Page 9: ...l work with a standard program that has been set at the factory If this doesn t suit you it s very easy to change it when you ve read this introductory section simply turn to the page for your timeswitch model Remember Make your changes using the SET YES and buttons You can t set ON1 as the last timing before midnight but you can set OFF3 after midnight providing it s not more than 23 hours and 59...

Page 10: ...you might need to change the way you use your system temporarily perhaps due to an exceptionally cold day Here s how to do it without affecting the timings in your program Switching on and off On the front of the timeswitch there is an Advance Boost button It allows you to switch your system either on or off irrespective of the program So if the heating is off and you want warmth now you can eithe...

Page 11: ... flap to change the mode This won t alter the timings in your program which you can return to by selecting TIMED THE LP111Si 24hr ELECTRONIC TIMESWITCH LP111Si a 24hr program up to 3 heating periods each day and every day the same Want to leave a timing as it is Just press SET and move on to the next one If you need to reset your timings to the standard program and start again press SET and togeth...

Page 12: ...nd together to go back to the pre set program Your system will come on for up to 3 heating periods every 24hrs ON1 starts the first one OFF1 finishes it and so on Notice that ON2 and OFF2 are set to the same time This means your system won t respond but if you want to activate that middle period or change any other timings read on The standard program When you press SET after setting OFF3 the time...

Page 13: ...warning SWITCHING STANDARD PROGRAM MON FRI SAT SUN ON 1 start of first timed period 6 30am 7 00am OFF 1 end of first timed period 8 30am 9 00am ON 2 start of second timed period 12 00pm 12 00pm OFF 2 end of second timed period 12 00pm 12 00pm ON 3 start of third timed period 4 30pm 4 00pm OFF 3 final switch off of the day 10 30pm 11 00pm THE LP711Si 7 DAY ELECTRONIC TIMESWITCH Cont Changing the ti...

Page 14: ... in the same way press SET then repeat the procedure for ON2 OFF2 ON3 and OFF3 Set each day If after you ve set OFF3 you want to fine tune one or more weekdays press SET until you find the first day you want to adjust then go through the procedure altering any time you wish Press SET to move on to the next day When you ve finished press SET until you see SET SAT SUN PROG If you don t want to alter...

Page 15: ...ep this guide in a safe place for future reference INTRODUCTION Lifestyle Programmers will automatically switch your central heating and hot water on and off at times that suit you Depending on your system central heating and hot water can either both come on and off at the same time or work independently The light on the front of the programmer shows when each one is on SAT timings on ch day d mo...

Page 16: ...rd program that has been set at the factory If this doesn t suit you it s very easy to change it when you ve read this introductory section simply go to the section that contains your programmer model Remember Make your changes using the SET YES and buttons on the programmer found under the bottom flap You can t set ON1 as the last timing before midnight but you can set OFF3 after midnight providi...

Page 17: ...e for central heating and one for hot water They allow you to switch your system either on or off irrespective of the program So if the heating or hot water is off and you want warmth or hot water now you can either 1 Press Advance to switch it on ADV will be displayed and it will stay on until the end of the next period Or if the heating hot water is on and you don t need it press Advance and it ...

Page 18: ...hot water operating together on the same timings for every day of the week But it s easy to make changes and have heating and water working independently just follow the instructions Want to leave a timing as it is Press SET and move on to the next one If you need to reset your timings to the standard program and start again press SET and together to go back to the pre set program If you don t pre...

Page 19: ...d or change any other timings read on Changing the timings Press the SET button and you ll see SET PROG Set the central heating Press the YES button and the display will ask SET CH PROG Press YES and you ll see ON1 the start of your first central heat ing period Adjust it in 1 minute steps using the and but tons If the and buttons are held down the time changes in 10 minute steps PROG PROG CH Pres...

Page 20: ...22Si 5 2 DAY ELECTRONIC PROGRAMMER LP522Si a 5 2 day program allowing for different timings at the weekends with central heating and hot water working independently for up to 3 heating periods each day If the timings haven t been set for you then your programmer will still be on the factory set standard program This means that central heating and hot water will operate together with the same timin...

Page 21: ...ot water will operate together with the same timings for weekdays and different ones for the weekend But it s easy to make changes and have heating and water working independently just follow the instructions Want to leave a timing as it is Press SET and move on to the next one If you need to reset your timings to the standard program and start again press SET and together to go back to the pre se...

Page 22: ...ange T CH PROG st central heat and but me changes in Press SET and you ll see OFF1 the end of your first central heating period Adjust this in the same way press SET then repeat the procedure for ON2 OFF2 ON3 and OFF3 Set weekday hot water When you press SET after setting OFF3 for the central heating the display will ask SET HW MON to FRI PROG Press YES then set your times in the same way Remember...

Page 23: ...imings on each day of the week with central heating and hot water working independently for up to 3 heating periods each day If the timings haven t been set for you then your programmer will still be on the factory set standard program This has central heating and hot water operating together with the option of having different timings for each day of the week But it s easy to make changes and hav...

Page 24: ...1 finishes it and so on Notice that ON2 and OFF2 are set to the same time This means your system won t respond but if you want to activate that middle period change any other timings read on Changing the timings Press the SET button and you ll see SET PROG PROG SERVICE INT Applicable t If your instal then your pr 30 days befo then then and then rev The display this it mean Cont ET CH MON to rst ce...

Page 25: ...FF3 for the weekday central heating the display will ask SET HW MON to FRI PROG Press YES then set your hot water times in the same way Remember in this mode you can have different times to your central heating if you wish Set each day If after you ve set OFF3 for your hot water you want to fine tune one or more weekdays press SET until you find the first day you want to adjust then go through the...

Page 26: ...l you see SET SAT SUN PROG Set weekend Press YES and alter the central heating and hot water times in the same way When you press SET after OFF3 for HW SAT SUN the pro grammer will ask the question TEST If you want to test your program see below otherwise press SET again If you don t want to test your program press SET again and you ll be asked the question SET H DAY If you want to set a holiday s...

Page 27: ... service is due it will display An audible alarm will sound push any button to snooze the alarm for 24hrs If you haven t already arranged for a service you should contact your service engineer immediately SETTING THE CLOCK AND DATE Applicable to all models SETTING THE CLOCK The clock in your programmer has been set at the factory and automatically accounts for British Summer Time However should yo...

Page 28: ... DATE The weekday is automatically calculated from the date so if the weekday is incorrect you ll need to reset the date contact your service engineer immediately SETTING THE CLOCK AND DATE Applicable to all models SETTING THE CLOCK The clock in your programmer has been set at the factory and automatically accounts for British Summer Time However should you need to set the clock read on first cent...

Page 29: ...and the day will start to flash Use the and but tons to adjust Set the Day Light Saving Press SET and the current DLS status will start to flash for day light saving British Summer Time Use the and buttons to turn on or off Make the wiring For surface wirin of the wall plate connection but convenience he first day e altering any day When T SUN pressing ater times in N the pro o test your If you do...

Page 30: ...P522 LP241 LP112 SM2 NOT USED 2 N 1 L 1 2 3 4 HW OFF CH OFF HW ON CH ON Mains Isolator 1 L 2 N 3 E 3A Drayton 22mm 3 Port Mid Position Valve 28mm 3 Port Mid Position Valve Function of Leads Blue Yell Green Grey Orange White 3 2 1 4 5 6 7 8 8 6 4 CH On HW Off Boiler Live HW on N E 5 8 7 2 3 1 2 3 4 5 6 7 8 9 10 11 12 L N E Refer to Boiler Handbook for wiring details of Pump Overrun boilers Use boil...

Page 31: ...333 7000622 Email customer care draytoncontrols co uk Web www draytoncontrols co uk LWC3 Junction Box Pump Boiler Room Thermostat Cyl Thermostat Programmer Mains Input 230V 50HZ 7 2 3 L N E 1 2 3 7 N E Switch L Perm L Refer to Boiler Handbook for wiring details of Pump Overrun boilers Use boiler manufactures instructions RTS 1 2 RTS 4 6 9 10 Function N N N L L E L 1 3 3 COM CALL SAT Function COM C...

Reviews: