Drayton DIGISTAT+2RF Installation & User Manual Download Page 13

Client

Drayton

File Name

7542 Drayton LP10RF & D2RF 06515086001 ISSC

Artworker

-

Proof Stage

PRINT

Finished Size

A5 148x210mm

Creative Director

Mike Lane

Artwork %

100%

Modification Date

21/08/15 2:56PM

Bleed

3mm

User Guide 

D2RF Room Thermostat

D2RF Room Thermostat

What is a programmable room thermostat? 
...an explanation for householders  

A programmable room thermostat is both a programmer 

and a room thermostat. A programmer allows you to set 

‘On’ and ‘Off’ time periods to suit your own lifestyle.  

A room thermostat works by sensing the air 

temperature, switching on the heating when the air 

temperature falls below the thermostat setting, and 

switching it off once this set temperature has been 

reached. 

So, a programmable room thermostat lets you choose  

what times you want the heating to be on, and what 

temperature it should reach while it is on. It will allow 

you to select different temperatures in your home at 

different times of the day (and days of the week) to meet 

your particular needs. 

Turning a programmable room thermostat to a higher 

setting will not make the room heat up any faster. How 

quickly the room heats up depends on the design of 

the heating system, for example, the size of boiler and 

radiators.

Neither does the setting affect how quickly the room 

cools down. Turning a programmable room thermostat 

to a lower setting will result in the room being controlled 

at a lower temperature, and saves energy. 

The way to set and use your programmable room 

thermostat is to find the lowest temperature settings 

that you are comfortable with at the different times you 

have chosen, and then leave it alone to do its job. The 

best way to do this is to set low temperatures first, say 

18°C, and then turn them up by one degree each day until 

you are comfortable with the temperatures. You won’t 

have to adjust the thermostat further. Any adjustments 

above these settings will waste energy and cost you more 

money. 

If your heating system is a boiler with radiators, 

there will usually be only one programmable room 

thermostat to control the whole house. But you can 

have different temperatures in individual rooms by 

installing thermostatic radiator valves (TRVs) on 

individual radiators. If you don’t have TRVs, you should 

choose a temperature that is reasonable for the whole 

house. If you do have TRVs, you can choose a slightly 

higher setting to make sure that even the coldest room 

is comfortable, then prevent any overheating in other 

rooms by adjusting the TRVs. 

The time on the programmer must be correct. Some 

types have to be adjusted in spring and autumn at the 

changes between Greenwich Mean Time and British 

Summer Time. 

You may be able to temporarily adjust the heating 

programme, for example, ‘Override’, ‘Advance’ or 

‘Boost’. These are explained in the manufacturer’s 

instructions. 

Programmable room thermostats need a free flow of air 

to sense the temperature, so they must not be covered 

by curtains or blocked by furniture. Nearby electric 

fires, televisions, wall or table lamps may prevent the 

thermostat from working properly.

Your Di2RF

The Di2RF thermostat is a programmable 

thermostat 24-Hour product (the same program for 

every day of the week) which allows you to set up to 6 

time and temperature events per day. 

Clock Setting

Your Di2RF is fitted with a real-time clock, which 

is pre-set at the factory. You will not have to alter the 

time settings. A special feature of this real-time clock is 

to automatically update the time during the summer/

winter time change removing the need to manually alter 

the clock. 

General Operation 

With the unit in Auto mode (the small arrow to bottom 

of screen will point to Auto) the temperature can be 

changed for a short time by using the + or - buttons. 

Changing the temperature in this way will keep the 

Di2RF set to your new temperature until the next 

pre-programmed event (at which time it will revert to 

programmed temperature). The temperature you are 

setting will flash on the screen. Once temperature is set, 

the unit will revert to showing the current temperature. 

The      indicator will show on the screen if the heating is 

turned on.

A flashing flame       indicates the product is in intelligent 

delayed start mode.

Drayton

Di2RF

Invensys Controls Europe

Customer Service Tel: 0845 130 5522
Customer Service Fax: 0845 130 0622
Technical Helpline Tel: 0845 130 7722
Website: www.draytoncontrols.co.uk
Email: [email protected]
User Guide 06490097001 IssA

Programmable Room

Thermostat Wireless
24 Hour
Model: 
RF700/22090
Power Supply: 
Battery - Thermostat
Mains - Digistat SCR

The Di2RF thermostat is a programmable thermostat 24-Hour
product (the same program for every day of the week) which
allows you to set up to 6 time and temperature events per day.

Clock Setting
Your Di2RF is fitted with a real-time clock, which is pre-set
at the factory. You will not have to alter the time settings. 
A special feature of this real-time clock is to automatically update
the time during the summer/winter time change removing the
need to manually alter the clock. 

General Operation
With the unit in Auto mode (the small arrow to bottom of screen
will point to Auto) the temperature can be changed for a short
time by using the + or - buttons.  Changing the temperature in
this way will keep the Di2RF set to your new temperature
until the next pre-programmed event (at which time it will revert
to programmed temperature).  The temperature you are setting
will flash on the screen.  Once temperature is set, the unit will
revert to showing the current temperature.  The  indicator will
show on the screen if the heating is turned on.

User Instructions

Event

1

2

3

4

5

6

Time

6:30

8:30

12:00

14:00

16:30

22:30

Temperature

20.0

16.0

16.0

16.0

21.0

7.0

The Di2RF thermostat is a programmable thermostat
24-Hour (the same program for every day of the week) and
allows you to set 6 time and temperature events per day.

Di2RF
Pre-set Program

Your Di2RF comes with the following default settings 
pre-programmed for your convenience:

Pre-set Program 1. (9 til 5)

*The above settings can be understood using the chart below

1

2

3

4

5

6

25ºC

20ºC

15ºC

10ºC

5ºC

06:30 08:30 12:00 14:00 16:30 22:30

Time Period

Room

Temp

As you can see, at 06:30 , the heating will come on to raise the
temperature to 20ºC.  At 08:30, the temperature set point is
dropped from 20ºC down to16ºC, it stays at 16ºC throughout the
day, until 16:30 when the temperature increases to 21ºC.  The
temperature then drops down to a night-setback temperature of
7ºC until 06:30 when the cycle repeats for the next day.

To adjust these times and temperatures

1. With the product operating as 

normal in the Auto mode 
press 

twice until the 

display is flashing as shown.
The time will be flashing, use 
the + or - buttons to adjust 
the 1st time as required

(* small 1 in lower half of screen

shows which time period is being set

e.g. 1=1st period, 2 = 2nd period etc)

Congratulations!

The unit is now set correctly to follow your required timings.

Basic Settings

Your Di2RF

Controls and Display Layout

What is a programmable room thermostat?

...an explanation for householders

A programmable room thermostat is both a programmer and a room

thermostat. A programmer allows you to set ‘On’ and ‘Off’ time

periods to suit your own lifestyle. A room thermostat works by sensing

the air temperature, switching on the heating when the air

temperature falls below the thermostat setting, and switching it off

once this set temperature has been reached.
So, a programmable room thermostat lets you choose what times you

want the heating to be on, and what temperature it should reach

while it is on. It will allow you to select different temperatures in your

home at different times of the day (and days of the week) to meet

your particular needs.
Turning a programmable room thermostat to a higher setting will not

make the room heat up any faster. How quickly the room heats up

depends on the design of the heating system, for example, the size of

boiler and radiators.
Neither does the setting affect how quickly the room cools down.

Turning a programmable room thermostat to a lower setting will result

in the room being controlled at a lower temperature, and saves energy.
The way to set and use your programmable room thermostat is to

find the lowest temperature settings that you are comfortable with at

the different times you have chosen, and then leave it alone to do its

job. The best way to do this is to set low temperatures first, say 18

o

C,

and then turn them up by one degree each day until you are

comfortable with the temperatures. You won’t have to adjust the

thermostat further. Any adjustments above these settings will waste

energy and cost you more money.
If your heating system is a boiler with radiators, there will usually be only

one programmable room thermostat to control the whole house. But you

can have different temperatures in individual rooms by installing

thermostatic radiator valves (TRVs) on individual radiators. If you don’t

have TRVs, you should choose a temperature that is reasonable for the

whole house. If you do have TRVs, you can choose a slightly higher

setting to make sure that even the coldest room is comfortable, then

prevent any overheating in other rooms by adjusting the TRVs.
The time on the programmer must be correct. Some types have to be

adjusted in spring and autumn at the changes between Greenwich

Mean Time and British Summer Time.
You may be able to temporarily adjust the heating programme, for

example, ‘Override’, ‘Advance’ or ‘Boost’. These are explained in the

manufacturer’s instructions. 
Programmable room thermostats need

a free flow of air to sense the temperature,

so they must not be covered by curtains

or blocked by furniture. Nearby electric

fires, televisions, wall or table lamps

may prevent the thermostat from

working properly.

(Fig 3)

How to replace the batteries see fig 3.

Remove the battery cover using a coin. Replace the spent
batteries with 2 x 1.5V IEC LR6 (AA) Alkaline batteries ensuring
correct orientation. Replace the battery cover pressing fully home.

(Fig 1)

(Fig 2)

How do I know when to change the batteries.

When the batteries start to run low a battery icon will flash in the
display, to indicate “low battery” during this time the Di2RF
will function normally (see fig 1).
Please replace batteries with 2 x 1.5V IEC LR6 (AA) Alkaline batteries.
When the battery icon alone is shown in the display, the batteries
are completely exhausted and the Di2RF will cease to
function (see fig 2). Re-activate by replacing the batteries.

Drayton

Di2RF

To set a constant room temperature (Manual mode):

1. Press 

once, the display 

shows temperature flashing
(example 20 

0

C)

2. Press + or - buttons to 

adjust the temperature as
required. The temperature 
will stop flashing after 5 
seconds and start controlling 
at this temperature

3. To exit manual mode press

once, to return to auto.

To change temperature for a short period (Override):

1. Press + or - buttons to 

adjust set temperature. Set
temperature shown flashing

2. After 5 seconds will start

controlling at selected set 
point but displays actual room 
temperature. 2 chrevons 
indicates override mode. 

3. To exit override press 

once or wait until next change
in the pre-set program.

2. Once the time has been set 

press 

to confirm and 

use the + or – button to 
adjust required temperature
(temperature shown flashing)

3. Once the temperature has 

been set press 

to 

confirm and move to the next
time and temperature periods
to be adjusted confirming 
changes by pressing 
button. (max 6 periods).

4. To exit press         or

until you return to auto 
mode with the bottom arrow 
pointing to auto (as shown).

Certification Mark

Drayto n

Digist at +2RF

Digist at +2RF

Digist at +2RF

Digist at +2RF

Drayto n

Drayto n

Drayto n

A flashing flame       indicates the product is in intelligent delayed
start mode (see special note).

06490097001 IssA 24-1-07  13/2/07  11:59  Page 1

Drayton

Di2RF

Invensys Controls Europe

Customer Service Tel: 0845 130 5522
Customer Service Fax: 0845 130 0622
Technical Helpline Tel: 0845 130 7722
Website: www.draytoncontrols.co.uk
Email: [email protected]
User Guide 06490097001 IssA

Programmable Room

Thermostat Wireless
24 Hour
Model: 
RF700/22090
Power Supply: 
Battery - Thermostat
Mains - Digistat SCR

The Di2RF thermostat is a programmable thermostat 24-Hour
product (the same program for every day of the week) which
allows you to set up to 6 time and temperature events per day.

Clock Setting
Your Di2RF is fitted with a real-time clock, which is pre-set
at the factory. You will not have to alter the time settings. 
A special feature of this real-time clock is to automatically update
the time during the summer/winter time change removing the
need to manually alter the clock. 

General Operation
With the unit in Auto mode (the small arrow to bottom of screen
will point to Auto) the temperature can be changed for a short
time by using the + or - buttons.  Changing the temperature in
this way will keep the Di2RF set to your new temperature
until the next pre-programmed event (at which time it will revert
to programmed temperature).  The temperature you are setting
will flash on the screen.  Once temperature is set, the unit will
revert to showing the current temperature.  The    indicator will
show on the screen if the heating is turned on.

User Instructions

Event

1

2

3

4

5

6

Time

6:30

8:30

12:00

14:00

16:30

22:30

Temperature

20.0

16.0

16.0

16.0

21.0

7.0

The Di2RF thermostat is a programmable thermostat
24-Hour (the same program for every day of the week) and
allows you to set 6 time and temperature events per day.

Di2RF
Pre-set Program

Your Di2RF comes with the following default settings 
pre-programmed for your convenience:

Pre-set Program 1. (9 til 5)

*The above settings can be understood using the chart below

1

2

3

4

5

6

25ºC

20ºC

15ºC

10ºC

5ºC

06:30 08:30 12:00 14:00 16:30 22:30

Time Period

Room

Temp

As you can see, at 06:30 , the heating will come on to raise the
temperature to 20ºC.  At 08:30, the temperature set point is
dropped from 20ºC down to16ºC, it stays at 16ºC throughout the
day, until 16:30 when the temperature increases to 21ºC.  The
temperature then drops down to a night-setback temperature of
7ºC until 06:30 when the cycle repeats for the next day.

To adjust these times and temperatures

1. With the product operating as 

normal in the Auto mode 
press 

twice until the 

display is flashing as shown.
The time will be flashing, use 
the + or - buttons to adjust 
the 1st time as required

(* small 1 in lower half of screen

shows which time period is being set

e.g. 1=1st period, 2 = 2nd period etc)

Congratulations!

The unit is now set correctly to follow your required timings.

Basic Settings

Your Di2RF

Controls and Display Layout

What is a programmable room thermostat?

...an explanation for householders

A programmable room thermostat is both a programmer and a room

thermostat. A programmer allows you to set ‘On’ and ‘Off’ time

periods to suit your own lifestyle. A room thermostat works by sensing

the air temperature, switching on the heating when the air

temperature falls below the thermostat setting, and switching it off

once this set temperature has been reached.
So, a programmable room thermostat lets you choose what times you

want the heating to be on, and what temperature it should reach

while it is on. It will allow you to select different temperatures in your

home at different times of the day (and days of the week) to meet

your particular needs.
Turning a programmable room thermostat to a higher setting will not

make the room heat up any faster. How quickly the room heats up

depends on the design of the heating system, for example, the size of

boiler and radiators.
Neither does the setting affect how quickly the room cools down.

Turning a programmable room thermostat to a lower setting will result

in the room being controlled at a lower temperature, and saves energy.
The way to set and use your programmable room thermostat is to

find the lowest temperature settings that you are comfortable with at

the different times you have chosen, and then leave it alone to do its

job. The best way to do this is to set low temperatures first, say 18

o

C,

and then turn them up by one degree each day until you are

comfortable with the temperatures. You won’t have to adjust the

thermostat further. Any adjustments above these settings will waste

energy and cost you more money.
If your heating system is a boiler with radiators, there will usually be only

one programmable room thermostat to control the whole house. But you

can have different temperatures in individual rooms by installing

thermostatic radiator valves (TRVs) on individual radiators. If you don’t

have TRVs, you should choose a temperature that is reasonable for the

whole house. If you do have TRVs, you can choose a slightly higher

setting to make sure that even the coldest room is comfortable, then

prevent any overheating in other rooms by adjusting the TRVs.
The time on the programmer must be correct. Some types have to be

adjusted in spring and autumn at the changes between Greenwich

Mean Time and British Summer Time.
You may be able to temporarily adjust the heating programme, for

example, ‘Override’, ‘Advance’ or ‘Boost’. These are explained in the

manufacturer’s instructions. 
Programmable room thermostats need

a free flow of air to sense the temperature,

so they must not be covered by curtains

or blocked by furniture. Nearby electric

fires, televisions, wall or table lamps

may prevent the thermostat from

working properly.

(Fig 3)

How to replace the batteries see fig 3.

Remove the battery cover using a coin. Replace the spent
batteries with 2 x 1.5V IEC LR6 (AA) Alkaline batteries ensuring
correct orientation. Replace the battery cover pressing fully home.

(Fig 1)

(Fig 2)

How do I know when to change the batteries.

When the batteries start to run low a battery icon will flash in the
display, to indicate “low battery” during this time the Di2RF
will function normally (see fig 1).
Please replace batteries with 2 x 1.5V IEC LR6 (AA) Alkaline batteries.
When the battery icon alone is shown in the display, the batteries
are completely exhausted and the Di2RF will cease to
function (see fig 2). Re-activate by replacing the batteries.

Drayton

Di2RF

To set a constant room temperature (Manual mode):

1. Press 

once, the display 

shows temperature flashing
(example 20 

0

C)

2. Press + or - buttons to 

adjust the temperature as
required. The temperature 
will stop flashing after 5 
seconds and start controlling 
at this temperature

3. To exit manual mode press

once, to return to auto.

To change temperature for a short period (Override):

1. Press + or - buttons to 

adjust set temperature. Set
temperature shown flashing

2. After 5 seconds will start

controlling at selected set 
point but displays actual room 
temperature. 2 chrevons 
indicates override mode. 

3. To exit override press 

once or wait until next change
in the pre-set program.

2. Once the time has been set 

press 

to confirm and 

use the + or – button to 
adjust required temperature
(temperature shown flashing)

3. Once the temperature has 

been set press 

to 

confirm and move to the next
time and temperature periods
to be adjusted confirming 
changes by pressing 
button. (max 6 periods).

4. To exit press         or

until you return to auto 
mode with the bottom arrow 
pointing to auto (as shown).

Certification Mark

Drayto n

Digist at +2RF

Digist at +2RF

Digist at +2RF

Digist at +2RF

Drayto n

Drayto n

Drayto n

A flashing flame 

indicates the product is in intelligent delayed

start mode (see special note).

06490097001 IssA 24-1-07  13/2/07  11:59  Page 1

11

LP10RF & D2RF

06

51

5086

0

0

1 I

SS

C

Summary of Contents for DIGISTAT+2RF

Page 1: ...ication Date 21 08 15 2 56PM Bleed 3mm LP10RF DIGISTAT 2RF Radiofrequencycontrolledprogrammableroom thermostatwithdomestichotwaterprogrammer PartnumberRF560DR Installation UserGuide ForGREENSTARCDi GREENSTARiJUNIORandGREENSTARSiMODELSalso GREENSTARiSYSTEMandGREENSTARCDiSYSTEMMODEL onlywhenusedwith theoptionalintegraldiverter SparesPartnumber22090 SparesPartnumber22589DR ...

Page 2: ... Celsius Centigrade IP IngressProtection V Volt m metre mA milliAmpere Definitions DLS BST Summertimebegins LastSundayinMarchat 1 00amGMT Clocksareputforwardby1hour Summertimeends LastSundayinOctoberat 2 00amBST Clocksareputbackby1hour Protectyourenvironment Properbatteryrecycling Electronicdevicesandbatteries rechargeableornot shouldnotbedisposedofintoordinaryhouseholdwaste Instead theymustberecy...

Page 3: ...m Tableofcontents TechnicalData 2 InstallationGuide 3 LP10RFInstallation 4 WirelessCommissioning SignalStrength 5 6 SignalStrength 7 InstallerOptions 8 9 UserGuide 10 DIGISTAT 2RFRoomThermostat 11 ControlsandDisplayLayout 12 BasicSettings 13 15 UserOptions 15 19 BatteryChange 19 LP10RFProgrammer Receiver 20 TheStandardProgram 21 ChangingtheProgram 22 25 Maintenance 25 1 LP10RF DIGISTAT 2RF 0651508...

Page 4: ... Batterylife withalkalinebatteries approx 2years N A Batterybackuptimeanddate 10yearsmin 10yearsmin Shortestswitchingperiod 1minute 1minute Hotwaterpre heatsettings 3ON 3OFF Centralheatingsettings 6perday EnergyClass IV 2 Acc EU811 2013 812 2013 813 2013 814 2013 PollutionClass 2 2 SoftwareClass A A Ballpressuretest 90 C 90 C TechnicalData RelevantECDirectives 2006 95 ECLowVoltageDirective 2004 10...

Page 5: ... DIGISTAT 2RF06515086001ISSC Artworker Proof Stage PRINT Finished Size A5 148x210mm Creative Director Mike Lane Artwork 100 Modification Date 21 08 15 2 56PM Bleed 3mm InstallationGuide LP10RF DIGISTAT 2RF 3 LP10RF DIGISTAT 2RF 06515086001 ISSC ...

Page 6: ...singbefore switchingontheelectricalsupplyandboiler J Switchboileronwhencompleted CAUTION Isolatethemainselectricitysupply beforestartinganyworkandobserve allrelevantsafetyprecautions Observeelectro staticdischarge precautions donottouchthepcb circuit DANGER 230voltsdonottouchtheelectrical componentsorcircuits F InstallationGuide LP10RFProgrammer Receiver Clips Cover panel Tab Blanking plate Tab Co...

Page 7: ...secondsthedisplaywillshow rF whichindicates thattheDIGISTAT 2RFiscontinuouslysendinga signaltotheLP10RF receiver Thereceiverdisplaywillnowshowthe learnt transmittercodeandtheantenna aswellasthe signalstrengthasindicatedbythechevronsonthe righthandsideofthedisplay J Placethetransmitterinthedesiredfinalposition andreturntotheboilertocheckthereceiver display Theidealtransmitterpositionwillresult inth...

Page 8: ...suitablewallplugsand screws 3 Replacethefrontcoverbylocatinginpositionand pushingfullyontothebackcover Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2R...

Page 9: ... buttononthetransmitter whilere insertingthebatteriesandkeepthebutton depresseduntilthedisplayshows rF 6 30 OFF 6 30 OFF 6 30 OFF 6 30 OFF LEDIndication Chevrons RFStrength Green 4 Verystrong Amber 3 Strong Red 2 Weak None 1 Veryweak Tocancelsignalstrengthmode 1 Removethebatteriesfromthetransmitterto canceltheconstanttransmission 2 Afterafewsecondsthereceiverdisplaywillshow 3 Press OK onthereceive...

Page 10: ...ait until next change in the pre set program temperature shown flashing 3 Once the temperature has been set press to confirm and move to the next time and temperature periods to be adjusted confirming changes by pressing button max 6 periods 4 To exit press or until you return to auto mode with the bottom arrow pointing to auto as shown Drayto n Digist at 2RF Digist at 2RF Drayto n Drayto n Drayto...

Page 11: ...iodisoperatingindicatedbythe flamesymbolflashing pressinganybuttonreturnsthe Digistattoautomodeallowingnormalbuttonoperation untilthenexttime temperatureevent whenitwill resumethedelaystartmodeorfollowstheHoliday Manual OverrideorOffmodesasselected Changestotheinstalleroptionsandpre setprogrammes mustbemadewiththeflamesymbolnotflashing Option10 ValveProtection Insomeheatingsystemstheremaybearequir...

Page 12: ...UserGuide LP10RF DIGISTAT 2RF 10 Installation UserGuide 06515086001 ISSC ...

Page 13: ... Room Thermostat Wireless 24 Hour Model RF700 22090 Power Supply Battery Thermostat Mains Digistat SCR The Digistat 2RF thermostat is a programmable thermostat 24 Hour product the same program for every day of the week which allows you to set up to 6 time and temperature events per day Clock Setting Your Digistat 2RF is fitted with a real time clock which is pre set at the factory You will not hav...

Page 14: ...left hand button moves the pointer to the left for selection Holiday Manual Auto Day Program Pointer mode indicator Time Flame shows when calling for heat Pointer day Days Temperature NOTE Temperaturedisplayedisactualroomtemperature unlessadjustingthe or buttonwhenitdisplays thesettemperature Onceadjustmentiscomplete andafter5secondsthiswillreturntoactualroom temperature UserGuide DIGISTAT 2RFRoom...

Page 15: ...ame program for every day of the week and allows you to set 6 time and temperature events per day Digistat 2RF Pre set Program Your Digistat 2RF comes with the following default settings pre programmed for your convenience Pre set Program 1 9 til 5 The above settings can be understood using the chart below 25ºC 20ºC small 1 in lower half of screen shows which time period is being set e g 1 1st per...

Page 16: ...gistat 2RF Alkaline batteries play the batteries will cease to tteries Drayton To set a constant room temperature Manual mode 1 Press once the display shows temperature flashing example 20 0 C 2 Press or buttons to adjust the temperature as required The temperature will stop flashing after 5 seconds and start controlling at this temperature 3 To exit manual mode press once to return to auto To cha...

Page 17: ...0 the tem 19 C until 12 00 w temperature to 21 when it drops to temperature to 21 temperature drop 06 00 when the cy To switch OFF the thermostat Press the and simultaneously for 5 seconds until the OFF is displayed The thermostat and heating system will now be OFF unless the temperature in the controlled space falls below 7 C the frost protection set point Please note this does not affect the ope...

Page 18: ... temperature Set temperature shown flashing 2 After 5 seconds will start controlling at selected set point but displays actual room temperature 2 chrevons indicates override mode 3 To exit override press once or wait until next change in the pre set program 2 Once the time has been set press to confirm and use the or button to adjust required temperature temperature shown flashing 3 Once the tempe...

Page 19: ...or a short ging the temperature in to your new temperature t which time it will revert perature you are setting ure is set the unit will ure The indicator will ned on Event 1 2 3 4 5 6 Time 6 30 8 30 12 00 14 00 16 30 22 30 Temperature 20 0 16 0 16 0 16 0 21 0 7 0 The Digistat 2RF thermostat is a programmable thermostat 24 Hour the same program for every day of the week and allows you to set 6 tim...

Page 20: ...rt below 1 2 3 4 5 6 25ºC 20ºC 15ºC 10ºC 5ºC 06 30 08 30 12 00 14 00 16 30 22 30 Time Period Room Temp As you can see at 06 30 the heating will come on to raise the temperature to 20ºC At 08 30 the temperature set point is dropped from 20ºC down to16ºC it stays at 16ºC throughout the day until 16 30 when the temperature increases to 21ºC The temperature then drops down to a night setback temperatu...

Page 21: ...bol flashing Fig12 pressing any button returns the Digistat 2RF to auto mode allowing normal button operation until the next time temperature event when it will resume the delay start mode or follows the Holiday Manual Override or Off modes as selected Changes to the installer options and pre set programmes must be made with the flame symbol not flashing What is Intelligent delayed start Intellige...

Page 22: ...imingsforyou your programmerwillworkwithastandardprogramthathas beensetatthefactory Ifthisdoesn tsuityou it svery easytochangeit NormalOperation Duringnormaloperationthereceiverwillflashthered LED approximatelyeveryfiveminutes Thisindicatesthata radiosignalisbeingreceivedfromtheDigistattransmitter RadioSignalLoss IftheredLEDdoesnotflashapproximatelyeveryfive minutesthenthereceiverwillshowaflashing...

Page 23: ...together forthreesecondsor longer torestorethedefaultprogramtimestothose showninthetableopposite Switching Weekdays Weekends HW HW 1stON startoffirsttimedperiod 6 30am 7 00am 1stOFF endoffirsttimedperiod 8 30am 9 00am 2ndON startofsecondtimedperiod 12 00pm 12 00pm 2ndOFF endofsecondtimedperiod 12 00pm 12 00pm 3rdON startofthirdtimedperiod 4 30pm 4 00pm 3rdOFF finalswith offoftheday 10 30pm 11 00pm...

Page 24: ...RI 8 30 6 30 UserGuide LP10RFProgrammer Receiver ChangingtheProgram Repeatoperations4to7tosetthesecondandthirdON OFFtimes NOTE Afterpressingset forthethirdhotwaterpre heat OFFtimethedisplayshowsSETMON Settingindividualweekdays NOTE Ifyoudonotrequireindividualweekdaytimes thenpressset untilSETSAT SUNaredisplayed andcontinueonthenextpage Ifyoudonotwish tochangethesettingforthedaydisplayed then press...

Page 25: ...0 PROG SAT SUN SAT SUN SAT SUN PROG PROG PROG 9 00 PROG OFF HW HW ON 9 00 6 30 NOTE Speedupthedisplaybyholdingdownthe or buttons Repeatoperations3to6tosetthesecondandthirdON OFFtimes NOTE Afterpressingset forthethirdhotwaterpre heat offtimeforSAT thedisplaywillshowSETSUN Press OKtosetSUNorpressset untilthedisplayreturns tonormalmode Settingindividualweekenddays NOTE Ifyoudonotrequireindividualweek...

Page 26: ...ndtime 1 Presstheset buttonuntilSETandCLOCK are showninthedisplay 2 PressOKtodisplay24hrandON 3 Press toswitchbetween24hrand12hrdisplay 4 Decidebetween24houror12hourdisplayand pressset toselect nowthehourswillflash 5 Press or tosetthecorrecthour 6 Whenthecorrecthourhasbeenselected press set toselect nowtheminuteswillflash 7 Press or tosetthecorrectminutes 8 Whenthecorrectminuteshavebeenset pressse...

Page 27: ...orrectdayhasbeenchosen pressset toselect nowdLSwillbedisplayedandONwill flash 9 Press or toswitchbetweenONorOFF Ifyou chooseONthentheclockwillautomaticallyadjust thetimeforDaylightsaving IfyouchooseOFF thenthetimewillnotchangetotakeaccountofthe DaylightSavingtimechangetwiceayear J Pressset twicetoreturntothenormaldisplay NOTE dLS DayLightSavingstime DATE DATE DATE MON 36 DATE DATE DATE DATE MON 36...

Page 28: ...06515086001ISSC Support Sales 44 0 845 1305522 Technical 44 0 845 1307722 customer care draytoncontrols co uk www draytoncontrols co uk DraytonHeating DraytonControls ...

Reviews: