The Industry-Standard High-End Noise-Gate comes to the 500 Series!

The DS101 is the first noise gate designed specifically for the 500 Series rack
system and takes its place alongside the Drawmer family of industry standard
Noise Gates, such as the DS201, DS501 and DS404. Anyone familiar with those
units will immediately be at home with the DS101.

Based on a single-channel of the DS201 the DS101 is a sophisticated noise gate
incorporating a number of features pioneered by Drawmer, which are invaluable to
the sound engineer, such as variable high and lowpass filters for “frequency
conscious gating.” Other features include comprehensive envelope control, attack,
hold, decay, and range, plus a whole host of other features, all adding up to one
amazing processor.

When placed side by side in a 500 series rack two or more gates can be linked
using the new infra red triggering mechanism employed on the DS101. This means
that any number of gates can be linked with each having their own envelope shaping
whilst the trigger pulse passes through unchanged, this opens up a whole world
of “envelope follower” effects limited only by your imagination.

Drawmer DS101 single-channel Noise Gate Features at a Glance:

Fully featured noise gate based on the industry standard DS201.
Takes up a single 500 series slot.
Proprietary Hysteris or “trigger stabilization” to prevent “chatter” around the
threshold.
Fully variable high pass and low pass filters for “frequency conscious” gating.
Comprehensive envelope control, attack, hold, decay, and range.
External triggering via key input or the new IR trigger pulse from another DS101.
“Key Listen” facility.
Extremely fast attack time, to preserve the natural attack of the sound.
Linkable - up to ten units in one rack space.
Drawmer “traffic lighting” metering.
Can be used for “Gating” or “Ducking”.
Low noise design.

DS101

NOISE GATE 

FOR THE

500 SERIES RACK SYSTEM

Summary of Contents for DS101

Page 1: ...tion Typical Connection Guide Chapter 2 Control Description The Gate Controls The Key Filters Quick Start Guide Noise Gate Operation Chapter 3 General Information If a fault develops Contacting Drawme...

Page 2: ...GES Some states and specific countries do not allow the exclusion of impliedwarrantiesorlimitationsonhowlonganimpliedwarrantymay last sotheabovelimitationsmaynotapplytoyou Thiswarrantygives youspecifi...

Page 3: ...r more gates can be linked using the new infra red triggering mechanism employed on the DS101 This means that any number of gates can be linked with each having their own envelope shaping whilst the t...

Page 4: ...connectors provided by an API 500 series compatible rack frame not included Installing the DS101 into a 500 Series compatible rack 1 Before you install anything be sure to turn off the 500 series rac...

Page 5: ...5 DS101 Noise Gate for 500 Series Systems TYPICAL CONNECTION GUIDE...

Page 6: ...ustry standard DS201 Noise Gate manufactured by Drawmer since 1981 The Gate Controls Threshold Infinite to 62 0dB Sets the level below which gating starts to take place For normal noise removal applic...

Page 7: ...will be reduced when open triggered Traffic Light Meter A three led meter is used to show the operation of the gate When red the gate is closed when green the gate is open and when yellow the gate is...

Page 8: ...Bypass switches remain indepentent In this way the triggers are the same but differing envelopes can be used for each channel Using External Keys An external audio source may be used to control the G...

Page 9: ...the following suggestions 1 Select the Key trigger source using the Key section 2 Initially the LF filter should be set fully anticlockwise with HF fully clockwise This will allow the full audio spect...

Page 10: ...from its zero level point as this wave climbs towards its peak the level will suddenly exceed the threshold setting at this point a very fast attack rate will switch the signal through the noise gate...

Page 11: ...al where the peaks are too loud and require attenuating In this application Duck and Internal i e source switch not selected modes should be selected and the Range control adjusted to give the desired...

Page 12: ...e acoustic guitar even a bright sounding steel strung model and the filters can be used to reduce the effect of string squeak or the player s breathing When recording drum kits most engineers encounte...

Page 13: ...ely that the Threshold will have to be re adjusted as the level may have to be quite high and you will have to be careful not to miss the quieter hits but the hi hat should be gated completely with no...

Page 14: ...ey input is making particular parts start and finish at the same time Regarding vocals and brass sections performers may start a fraction early some end a fraction late Link the channels and use the b...

Page 15: ...mber will be issued Write this RA number in large letters in a prominent position on the shipping box Enclose your name address telephone number copy of the original sales invoice and a detailed descr...

Page 16: ...16 DRAWMER Ref 1v01 B 24 01 13 BLOCK DIAGRAM...

Page 17: ...17 DS101 Noise Gate for 500 Series Systems...

Reviews: