background image

4

DRAWMER

The CPA-50 unit will be supplied with a power cable suitable for domestic power
outlets in your country. For your own safety, it is important that you use this cable to

connect to the mains supply earth. The cable must not be tampered with or modified.
The power supply socket has an integral fuse drawer containing the power fuse of
the same value, to suit the mains voltage for which the unit has been supplied.

Removal of the drawer is only possible with the power cord removed. The fuse
should never blow under normal operation. If the fuse is suspected of having blown,
then a fault will have occurred and this fault condition should be inspected by a

qualified service engineer. When replacing the fuse, always comply with the Safety
Instructions.

If the unit is to be used with a mains input
operating voltage different to that for which
the unit is supplied, the following

procedure must be carried out by a
technically competent person:

1: Disconnect the unit from the mains
and cable.

2: Using a No.1 size pozidrive
screwdriver, remove the four screws
that retain the top cover.

For conversion to 230Volt AC
(previously set to 115Volt AC).....

3a. remove the jumper across the
CON101 socket
3b. Exchange the T800mA fuse below

the  mains  socket  for  a  similar  type
rated at T500mA

For conversion to 115Volt AC
(previously set to 230Volt AC).....

4a. Add a jumper across the CON101 socket

4b. Exchange the T500mA fuse below the mains
socket for a similar type rated at T800mA

In all cases:

5: Replace the top cover using the four screws.
6: Re-connect to mains power source.

POWER CONNECTION

PORTABLE APPLIANCE TESTING

To undergo a Portable Appliance Testing procedure (commonly known as "PAT",

"PAT Inspection" or "PAT Testing") remove the screw on the right side of the CPA-50,

nearest the IEC socket that holds the cover in place and probe in this cavity.

Alternatively, the screw can be replaced for something more suited to the job, such

as a spade terminal with a self tapping M3 thread.

Summary of Contents for CPA-50

Page 1: ...ction Introduction Power Connection Portable Applinace Testing Typical Connection Guide Chapter 2 Control Description Contol Description Example Wiring Methods Chapter 3 General Information If a fault...

Page 2: ...oyou This warrantygives youspecificlegalrights Youmayhaveadditionalrightsthat varyfrom stateto state andcountry to country For the USA FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE ST...

Page 3: ...fit into a bag to take anywhere As well as working in stereo the CPA 50 can also function as a 100Wrms into 8ohms Monoblock set via internal jumpers which allows the system to operate in bi amped or...

Page 4: ...procedure must be carried out by a technically competent person 1 Disconnect the unit from the mains and cable 2 Using a No 1 size pozidrive screwdriver remove the four screws that retain the top cov...

Page 5: ...5 CPA 50 Power Amplifier TYPICAL CONNECTION GUIDE STANDARD STEREO WIRING 50 50Wrms into 4 Ohms 1 THD...

Page 6: ...ill be heard as very short interrupts to the sound Over voltage shutdown If the mains voltage exceeds the absolute maximum rated level of 90 132 180 264 VAC the MPA will momentarily shut down and the...

Page 7: ...outputs connectors are in the form of binding posts that can be wired directly to the speaker terminals via bare wires through the hole and tightened via spade terminals or via banana plugs The diagra...

Page 8: ...8 DRAWMER STEREO BI WIRING 50 50W rms into 4 Ohms 1 THD HORIZONTAL BI AMPING 2 Required 100 100W rms into 4 Ohms 1 THD EXAMPLE WIRING METHODS...

Page 9: ...9 CPA 50 Power Amplifier VERTICAL BI AMPING 2 Required 100 100W rms into 4 Ohms 1 THD STEREO VIA MONOBLOCKS 2 Required 100 100W rms into 8 Ohms 1 THD...

Page 10: ...unit is to be returned the original container must be used If this container is not available then the equipment should be packaged in substantial shock proof material capable of withstanding the hand...

Page 11: ...1 1 CPA 50 Power Amplifier THD Noise vs Power...

Page 12: ...Drawmer Electronics Ltd Coleman St Parkgate Rotherham South Yorkshire U K DRAWMER...

Reviews: