POWER

On / Standby

The unit has a soft on/off switch on the front panel. With the switch in the CPA-50 is
active and the LED indication beneath lights. With the switch out it is operating in
standby - the standby LED illuminates and the CPA-50 draws 0.5 Watts of power.

STATUS

Fault

Fault:

 

This is illuminated is the MPA has detected an error via it’s in built sensors,

these include:

Power shut down by over temperature

 - If the temperature inside the MPA should

pass the threshold of 100°C minimum to 110°C maximum (105°C typical) the MPA
will shut down for a few moments. The shutdown time is short but increases as the
unit heats up. As well as the illumination of the LED indication this protection mode
will be heard as very short interrupts to the sound.

Over voltage shutdown

. - If the mains voltage exceeds the absolute maximum

rated level of ~ 90-132 / 180-264 VAC the MPA will momentarily shut down and the
Fault LED will illuminate. This protection mode will be heard as very short interrupts
to the sound. In the event of a fault occurring the source of the problem should be
repaired before permanent damage to the system occurs.

Bridge:

To set Bridge mode, to use the
CPA-50 as a monoblock, remove
the cover by unscrewing the four
screws. Set the jumpers on
connectors J7 and  J10 to the
position shown in the diagram
(right). Replace the cover.
Note:  Use  only  the  left  input,  and
connect  to 

R

-

  and 

L

+

 speaker

terminals (R+ & L- are not used).

The Bridge LED will be inactive in
stereo mode, providing
50+50Wrms into 4 Ohms. When
the Bridge LED is illuminated it
indicates that the CPA-50 is set to
Bridge (mono) mode, providing
1x100Wrms into 8 Ohms.

1

2

Summary of Contents for CPA-50

Page 1: ...ction Introduction Power Connection Portable Applinace Testing Typical Connection Guide Chapter 2 Control Description Contol Description Example Wiring Methods Chapter 3 General Information If a fault...

Page 2: ...oyou This warrantygives youspecificlegalrights Youmayhaveadditionalrightsthat varyfrom stateto state andcountry to country For the USA FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE ST...

Page 3: ...fit into a bag to take anywhere As well as working in stereo the CPA 50 can also function as a 100Wrms into 8ohms Monoblock set via internal jumpers which allows the system to operate in bi amped or...

Page 4: ...procedure must be carried out by a technically competent person 1 Disconnect the unit from the mains and cable 2 Using a No 1 size pozidrive screwdriver remove the four screws that retain the top cov...

Page 5: ...5 CPA 50 Power Amplifier TYPICAL CONNECTION GUIDE STANDARD STEREO WIRING 50 50Wrms into 4 Ohms 1 THD...

Page 6: ...ill be heard as very short interrupts to the sound Over voltage shutdown If the mains voltage exceeds the absolute maximum rated level of 90 132 180 264 VAC the MPA will momentarily shut down and the...

Page 7: ...outputs connectors are in the form of binding posts that can be wired directly to the speaker terminals via bare wires through the hole and tightened via spade terminals or via banana plugs The diagra...

Page 8: ...8 DRAWMER STEREO BI WIRING 50 50W rms into 4 Ohms 1 THD HORIZONTAL BI AMPING 2 Required 100 100W rms into 4 Ohms 1 THD EXAMPLE WIRING METHODS...

Page 9: ...9 CPA 50 Power Amplifier VERTICAL BI AMPING 2 Required 100 100W rms into 4 Ohms 1 THD STEREO VIA MONOBLOCKS 2 Required 100 100W rms into 8 Ohms 1 THD...

Page 10: ...unit is to be returned the original container must be used If this container is not available then the equipment should be packaged in substantial shock proof material capable of withstanding the hand...

Page 11: ...1 1 CPA 50 Power Amplifier THD Noise vs Power...

Page 12: ...Drawmer Electronics Ltd Coleman St Parkgate Rotherham South Yorkshire U K DRAWMER...

Reviews: