Wiring Diagrams—220V Standard Motor 

Schaltpläne—220 V Standardmotor 

Schémas de câblage : moteur standard 220 V

External Low Voltage and Wireless 

Externe Niederspannung und kabellos 

Basse tension externe et sans fil

Please Note:

 Do not wire motors in parallel

Bitte beachten:

 Motoren nicht parallel schalten

Remarque:

 Ne pas connecter les moteurs en parallèle.

GND

L1

N

White - Common to screen & 230V AC Neutral

Red - to screen 

(directional)

Brown - to 230V AC-Hot 

Yellow - to 230V AC-Hot 

Black - to 230V AC-Hot 

Green/Yellow 

(Ground)

Dashed wiring by electrician

Factory wiring

Low-voltage wiring by others

IR Eye Input

LVC-IV motor lead bundle

LVC-IV AC power input bundle

Low-Voltage

Trigger

4-28 VDC

RS232/485

Inputs/Outputs

3 Button Wall Switch 

DOWN - Black

COM - White

UP - Red

Wall Switch

Electrically Straight

Data Cable to more

LVC-IV modules.*

Location of key

operated on-off

switch if furnished. 

To

230 VAC

Line

*A maximum of six (6) 

 LVC-IV modules can 

 be linked together.  

Receiver

Button

FU

SE - 

3.1

5 A

M

P

25

0 V

AC 

5x

20

m

m

External LVC-IV - Single or Multiple Projection Screen Wiring Diagram - 220V

Blue 

(Common)

Black 

(Up)

Brown 

(Down)

INTERNAL SCREEN WIRING

Green/Yellow

(Motor Ground)

TO

:  MOTOR

 LE

ADS

Neutral

L1

220v, 
50 Hz. or/oder/ou 60 Hz.

Dashed wiring 

by installer/

Gestrichelte Verkabelung

durch Installateur/

Câblage en pointillés

par l'installateur

Control

switch/

Kontrollschalter/

Commutateur de commande

Single Station Control/Einstationsbedienung/

Commande monoposte

CE Approved/CE-zugelassen/Homologuée CE

Internal Screen Wiring/Interne 

Projektionsflächenverkablung/Câblage interne de l'écran

Projektionsflächenverkablung/Câblage interne de l'écran

Blue/Blau/Bleu-220v (Common/Gemeinsam/Commun)

Brown/Braun/Marron-220v (Down/Ab/Bas)

Black/Schwarz/Noir-220v (Up/Auf/Haut)

Neutral

Hot/

Stromführend/

Chaud

Multiple Station Control/Mehrstationsbedienung/

Commande multiposte

Not CE Approved/Nicht CE-zugelassen/Non homologuée CE

Red/Rot/Rouge

Red/Rot/Rouge

Red/Rot/Rouge

Blue/
Blau/
Bleu

Blue/
Blau/
Bleu

Blue/
Blau/
Bleu

Black/Schwarz/Noir

Black/Schwarz/Noir

220v, 50 Hz. or/oder/ou 60 Hz.

Black/Schwarz/Noir

Green-Yellow/Grün-Gelb/Vert-jaune

 

(Motor Ground/Motorerdung/

 

mise à la terre du moteur)

Control

switches/

Kontrollschalter/

Commutateurs

de commande

Internal Screen Wiring/Interne

Blue/Blau/Bleu-220v (Common/Gemeinsam/Commun)

Brown/Braun/Marron-220v (Down/Ab/Bas)

Black/Schwarz/Noir-220v (Up/Auf/Haut)

Green-Yellow/Grün-Gelb/Vert-jaune

 

(Motor Ground/Motorerdung/

 

mise à la terre du moteur)

Dashed wiring 

by installer/

Gestrichelte Verkabelung

durch Installateur/

Câblage en pointillés

par l'installateur

Neutral

L1

220v, 
50 Hz. or/oder/ou 60 Hz.

Dashed wiring 

by installer/

Gestrichelte Verkabelung

durch Installateur/

Câblage en pointillés

par l'installateur

Control

switch/

Kontrollschalter/

Commutateur de commande

Single Station Control/Einstationsbedienung/

Commande monoposte

CE Approved/CE-zugelassen/Homologuée CE

Internal Screen Wiring/Interne 

Projektionsflächenverkablung/Câblage interne de l'écran

Projektionsflächenverkablung/Câblage interne de l'écran

Blue/Blau/Bleu-220v (Common/Gemeinsam/Commun)

Brown/Braun/Marron-220v (Down/Ab/Bas)

Black/Schwarz/Noir-220v (Up/Auf/Haut)

Neutral

Hot/

Stromführend/

Chaud

Multiple Station Control/Mehrstationsbedienung/

Commande multiposte

Not CE Approved/Nicht CE-zugelassen/Non homologuée CE

Red/Rot/Rouge

Red/Rot/Rouge

Red/Rot/Rouge

Blue/
Blau/
Bleu

Blue/
Blau/
Bleu

Blue/
Blau/
Bleu

Black/Schwarz/Noir

Black/Schwarz/Noir

220v, 50 Hz. or/oder/ou 60 Hz.

Black/Schwarz/Noir

Green-Yellow/Grün-Gelb/Vert-jaune

 

(Motor Ground/Motorerdung/

 

mise à la terre du moteur)

Control

switches/

Kontrollschalter/

Commutateurs

de commande

Internal Screen Wiring/Interne

Blue/Blau/Bleu-220v (Common/Gemeinsam/Commun)

Brown/Braun/Marron-220v (Down/Ab/Bas)

Black/Schwarz/Noir-220v (Up/Auf/Haut)

Green-Yellow/Grün-Gelb/Vert-jaune

 

(Motor Ground/Motorerdung/

 

mise à la terre du moteur)

Dashed wiring 

by installer/

Gestrichelte Verkabelung

durch Installateur/

Câblage en pointillés

par l'installateur

External LVC-IV Junction Box

  2.214"

(56mm)

 4.5"

(114mm)

 10.39"

(264mm)

MO

TO

R L

EA

DS

W

A

LL

 S

W

IT

C

H

AC

 P

OW

ER

 IN

PU

T

W

A

R

N

IN

G

D

R

C

O

N

TA

C

T

C

LO

SU

R

O

N

LY

.

AP

PL

YI

N

G

 V

O

LT

AG

E

H

ER

W

ILL

 D

AM

AG

E

C

O

N

TRO

LLE

R

.

RF A

nten

na

Wire

page 7 of 8

220V Premier

Electric Projection Screen 

Elektrische Projektionsfläche 

Écran de projection électrique

Summary of Contents for Premier 220V

Page 1: ...t im Projektionsfl chenkarton verpackt Bitte nicht mit dem Verpackungsmaterial entsorgen Le ou les commutateurs sont emball s s par ment dans le carton d emballage de l cran NOT INCLUDED NOT INCLUDED...

Page 2: ...n Sie Projektionsfl chen an Bohrl chern in Stirnkappen auf S Haken Kette oder Drahtseil und Spannschrauben sollten vom Installateur bereitgestellt werden S Haken sollten durch die seitlichen Montagebo...

Page 3: ...universal brackets and into wall Montieren Sie die Projektionsfl che indem Sie die passenden Bau und Montageteile an den Universalhalterungen und der Wand installieren Monter l cran en installant le m...

Page 4: ...gh the cable exit hole Replace the endcap cover Ziehen Sie die braun blauen und wei en Kabel vorsichtig durch die Kabeldurchf hrung Setzen Sie die Stirnkappen wieder ein Avec pr caution tirer les fils...

Page 5: ...neinstellungen beschrieben eine Einstellung dieser Begrenzungen kann sich jedoch negativ auf die Ebenheit der Leinwandoberfl che auswirken und kann auch zum Verlust der Gew hrleistung f hren Bitte wen...

Page 6: ...cedure is outlined below for minor tweaks but any adjustment of these limits may negatively affect the flatness of the screen surface and could also void the warranty Please check with Draper prior to...

Page 7: ...al Hot Stromf hrend Chaud Multiple Station Control Mehrstationsbedienung Commande multiposte Not CE Approved Nicht CE zugelassen Non homologu e CE Red Rot Rouge Red Rot Rouge Red Rot Rouge Blue Blau B...

Page 8: ...LVC IV from the screen housing PLEASE NOTE Built In LVC IV will increase overall case length by 38mm 1 Entfernen Sie die zwei 2 Stern Schl sselschrauben aus dem Motor Ende des Siebgeh uses 2 Entferne...

Reviews: