Plenum Housing, Lift, and Closure

If you encounter any difficulties installing or servicing your 220 V a.c. Micro
Projector Lift, call your dealer or Draper, Inc. in Spiceland, Indiana, 765-987-
7999, or fax 765-987-7142.

Installing Optional Ceiling Trim Kit

The Micro Projector Lift is available with a ceiling trim kit. 

This kit consists of

the lower section of the plenum housing and the optional closure panel.

Please refer to drawings below for these instructions.

Install Micro Projector Lift as previously described in these instructions.

Install bottom section of plenum housing in opening. This can be
accomplished by suspending with wire, or by mounting directly to the
ceiling joists (if space permits).

Install projector and attach optional ceiling closure to Micro Projector Lift
(see instructions on page 3).

Upper Section

MPL

Middle Section

Lower Section

Ceiling tile

Lower section of
Plenum Housing

Installing Optional Plenum Housing

The Plenum Housing is shipped pre-assembled in its shortest position.  The
height of the plenum can be adjusted by moving the screws to different
mounting holes in side panels. You can install the plenum housing in a pre-
assembled state or as separate components, which will require that the
plenum housing be completely disassembled prior to installation.

Please Note:

If the plenum is to be installed in a space where there is no access from
above the plenum, then it is recommended that the Micro projector Lift
be installed to the upper section prior to installing the plenum housing.

Please refer to drawing below for these instructions.

Install top section of plenum housing using outer four holes located on top
of upper section.

Attach Micro Projector Lift to upper section of plenum housing through the
inner four holes in the upper section with the 

5

/

16

"–18 x 

7

/

8

" hex head

screws, 

5

/

16

" flat washers, and lock washers provided with plenum housing.

The lock washers should be used 

above the plenum housing (one per

screw); the flat washers should be used 

between the plenum housing and

the MPL (three flat washers per screw).

Attach the two flat panels of the middle section across from each other
with the clinch nuts to the outside of the housing.

Attach the two middle section panels with the formed ends across from
one another.

Attach lower section of plenum housing.

Use 25 mm foil tape (roll provided with plenum housing) to cover any
unused screw holes in plenum housing.

Overall

Height

508 mm Max.

305 mm Min.

Available

Projector/

Bracket

Height

343 mm Max.

140 mm Min.

Summary of Contents for Micro projector lift

Page 1: ...trical codes All operating switches should be off before power is connected Micro Projector Lift should be operated and checked prior to installing projector and or optional ceiling closure Caution Read instructions completely before proceeding Follow instructions carefully Installation contrary to instructions invalidates warranty Do not obstruct operation of Micro Projector Lift with fingers or ...

Page 2: ...ll the plenum housing in a pre assembled state or as separate components which will require that the plenum housing be completely disassembled prior to installation Please Note If the plenum is to be installed in a space where there is no access from above the plenum then it is recommended that the Micro projector Lift be installed to the upper section prior to installing the plenum housing Please...

Page 3: ...with nuts above and below slots Run unit up again to highest position Measure distance by which panel fails to reach required closed height for surrounding ceiling Run unit down then readjust mounting of 5 16 18 rods in traveling grid to raise panel required distance Test unit operation to confirm that panel will stop in closed position just before touching ceiling NOTE Immediately upon completion...

Page 4: ...by electrician Blue Black Red N O To 220v 50 Hz Line Blue Common Brown Up Green Ground White Black N DN UP Blue Red Blue Red Black Black Cap off with wire nut and tape Neutral Hot Motor Black Down Dashed wiring by electrician N O To 220v Line Blue Common Brown Up Green Ground White Black N DN UP STOP Control Switches 24v DC Black DN Red UP White COM Black DN Red UP White COM STOP Black Red White W...

Reviews: