background image

 WARNING   

Improper installation and use of the Fascia Dual Roller FlexShade

®

 can result in serious injury or death. Primarily, injuries can occur if the unit falls due to imprecise 

installation, mishandling of the unit during installation or installation on an insufficient wall or ceiling structure. Please use extreme care. 
1. 

Please read the following installation guidelines thoroughly and follow them 

carefully. Failure to do so may cause product to fall or otherwise fail, and could 

result in serious injury. 

2. 

Installation and calibration of the unit should only be performed by an 

authorized, qualified, and experienced professional. In particular, electrical work 

and wiring [indicated in diagram by dashed lines] must be completed only by a 

qualified professional electrician who has read this manual completely and is 

familiar with the construction and operation of this equipment and the hazards 

involved. 

3. 

Do not affix the unit to wall or ceilings that have inadequate strength to 

permanently hold the unit during use. It is the owner’s and installer’s 

responsibility to confirm the wall or ceiling to which the unit attaches is 

sufficient to permanently hold the weight and stress loads of the unit at all times. 

Draper, Inc., is not responsible for improper installation, application, testing, or 

workmanship related to the product at place of installation. 

4. 

It is the installer’s responsibility to make sure appropriate fasteners are used for 

mounting. 

5. 

All brackets, fascia, headboxes, pockets, wall clips, and other hardware must be 

installed level. Unit must be level and square. 

6. 

Never leave the area while operating the unit during installation, maintenance, or 

normal operation, unless it is secure and safe. 

7. 

Before testing or operation, carefully inspect the entire area and path of the 

shade and areas underneath the shade to be sure no persons or objects are in 

the area. 

8. 

Turn off power and any nearby equipment or cables carrying electricity before 

connecting switches, wires, controls, or electrical components. 

9. 

Make sure the limit switches are pointed down or accessible when placing the 

motor in brackets/endcaps.

10. 

All motors should be tested and limits set using test cord before shades are 

wired. 

11. 

Do not wire motors in parallel without written permission from Draper, Inc. 

12. 

During testing or operation, carefully watch the surrounding area for any 

potential safety concerns including nearby persons or objects. 

13. 

After installation, the entire system, including all sensors, should be carefully 

tested to ensure safe and normal operation. Extreme care should be taken 

during testing to remain clear of moving parts to avoid possible injury. 

14. 

Operation of unit should be performed only by authorized and qualified 

personnel, who have been trained in the safe and effective operation of the unit 

and understand its safety features. 

15. 

The safety features of the unit , including sensors, should never be disabled, 

bypassed, or overridden. The system should not be operated until all safety 

features, including the sensors, are properly and completely installed, 

calibrated, and tested. 

16. 

Unit may need to comply with local, state, or district rules and regulations, in 

particular when installed in schools. All applicable rules and regulations should 

be reviewed before installation and use. 

17. 

Failure to precisely follow installation guidelines invalidates all warranties. 

18. 

Custom products/installations may not be reflected in this manual. Call Draper, 

Inc., if you have questions about the installation of custom products or any 

questions about your installation. 

Before Beginning Installation

1. 

Look for any job site conditions that could interfere with installation or operation 

of the system.

2. 

Read carefully and be sure to understand all installation instructions and all 

related operations manuals. These instructions are intended to serve as a guide 

for the installer and owner. They should be followed closely and combined with 

the expertise of experienced qualified installers. Draper, Inc., is not responsible 

for improper installation, application, testing, or workmanship related to the 

product at place of installation. Please retain all instructions for future use.

3. 

Open cartons lengthwise.

4. 

Locate and lay out all pieces.

5. 

Inspect all boxes to make sure you have received the proper shade and parts. 

Controls may be shipped separately, or in same carton as shade.

6. 

If you have any difficulties with installing, servicing, or operating your shade, call 

your dealer or Draper, Inc., 765-987-7999.

Important Safety Information

Important Safety Information

PLEASE READ -

 Field Adjustments

Each Draper Solar Control Shade is tested to ensure 

proper operation. Even with this testing, some field 

adjustments may be needed for telescoping. 
If the shade is telescoping, place a piece of high quality 

gaffer tape about 1" 

(25 mm)

 wide on the exposed roller 

(where the fabric will cover it)

 on the side that the fabric will 

be drawn toward. For example: if the fabric is tracking 

to the left, place the tape on the right side.

PLEASE READ -

 Cleaning and Maintenance

Window covering products manufactured by Draper, when properly installed, should require no 

operational maintenance or lubrication.
Most of Draper’s standard fabrics may be cleaned at the window by vacuuming with a soft brush 

attachment. They also may be cleaned by using a sponge or soft cloth and mild solution of warm soapy 

water. A mild dishwashing liquid is recommended. A clean dry cloth is recommended for the metal finish. 

Please Note:

 Exceptions are Flocké and Phifer SW7000 fabrics, which must be cleaned with a dry  

art sponge.

PLEASE READ -

 Important Installation Information

 Caution:

 

1. 

Inspect all boxes to make sure you have received the proper shades and  

parts. Controls may be shipped separately, or in same carton as shades. 

2. 

Open cartons lengthwise.

3. 

Before mounting shades, verify measurements on label provided with shade, 

and ensure unit is installed at correct width.

4. 

Before connecting switches, controls, or electrical, ensure that power is  

turned 

OFF

. Wiring indicated in diagram by dashed lines must be completed  

by an electrician.

5. 

Do not wire motors in parallel without written permission from Draper.

6. 

All endcaps, fascia, pocket headbox, and other hardware must be installed 

level. Shades must be level and square.

7.  Read the following installation guidelines thoroughly and follow them 

carefully. Failure to do so may cause product to fall or otherwise fail,  

and invalidates warranty.

8.  Installer is responsible for selecting mounting hardware appropriate for  

site conditions.

PLEASE READ -

 Safety Information

page 2 of 10

Dual Roller Motorized FlexShade

®

 

(Standard Hardware)

Summary of Contents for FlexShade DFMO

Page 1: ...1 PLEASE READ Important Safety and Installation Information 2 PLEASE READ Field Adjustments Cleaning and Maintenance 2 Section 1 Mounting Endcaps 3 Section 2 Installing Fascia 3 Section 3 Dual Roller Surface Headbox Installation 4 Section 4 Pocket Headbox Installation 5 Section 5 Installing Closure Panel 6 Section 6 Limit Switch Adjustments 7 Section 7 Electrical Connections 7 9 Section 8 Standard...

Page 2: ...plicable rules and regulations should be reviewed before installation and use 17 Failure to precisely follow installation guidelines invalidates all warranties 18 Custom products installations may not be reflected in this manual Call Draper Inc if you have questions about the installation of custom products or any questions about your installation Before Beginning Installation 1 Look for any job s...

Page 3: ...s using appropriate fasteners for surface 5 Place operator motor end of rear shade into its endcap Fig 2 6 Secure motor plate with the provided clips Fig 2 7 Slide notched pin into idler endcap Secure with retainer clip and lock into place with rotating idler lock Fig 3 8 Use cord strap to secure electrical cord to endcap This will prevent the electrical cord from getting caught on the roller and ...

Page 4: ...x 2 Using pre drilled holes in endcaps mark headbox for drilling 3 Drill holes in back wall mount or top ceiling mount of top back cover piece 4 Attach endcaps and top back cover piece to wall or ceiling using mounting hardware appropriate for site conditions Please Note A minimum of two 2 screws is required for each endcap Next mount roller assemblies Section 4 IDLER ENDCAP COVER BACK COVER TOP C...

Page 5: ...ocket closure Fig 6 D 3 Drill small starter hole if necessary in mounting surface 4 Mount pocket headbox using appropriate fasteners for surface Section 4 Pocket Headbox Installation PLEASE NOTE Installer must provide adequate clearance for removal of Roller Assembly during installation and maintenance PLEASE NOTE Headbox must be mounted directly to ceiling or to a continuous blocking that is secu...

Page 6: ...hers Secured to Building Structure Continuous Blocking by others Ceiling by others Wall Clip pre attached to headbox Window 3 76mm Closure Panel WALL 3 76mm 5 146mm 7 197mm 1 29mm Headbox Headbox Closure Panel Closure Panel Figure 7 Figure 8 1 2 page 6 of 10 Dual Roller Motorized FlexShade Standard Hardware ...

Page 7: ...Back Bottom View Side View GLASS SIDE ROOM SIDE Front Back Bottom View Side View Screws Front Back Bottom View Side View GLASS SIDE ROOM SIDE Screws Front Back Bottom View Side View GLASS SIDE ROOM SIDE PUSH BUTTON LIMITS Standard right hand motor configuration shown SCREW TYPE LIMITS Standard right hand motor configuration shown Section 7 Electrical Connections Shade operates on 110 120V 60 Hz cu...

Page 8: ...0 5 cm Standard W B G Ø 0 61 15 5 mm 2 WHITE 2 WHITE 1 BLACK 3 RED 4 GREEN 2 WHITE 2 WHITE 2 WHITE 1 BLACK 3 RED 4 GREEN 2 WHITE W B R G To Switch 120VAC To Motor 60 1 5 m Standard 12 30 5 cm Standard M12 Connector for 4 Wire Motors Ø 0 61 15 5 mm Dashed Wiring by Electrician Controls System Overview Sonesse RTS 120VAC Motors M12 Connector B W G RTS MOTOR 120V 110 120V Line DecoFlex Wire Free Keyp...

Page 9: ...k Device Connector Network Device Connector Network Device Connector Handheld Remote Wireless Gateway Wall Switch AV Gateway Network Device Connector Contact Closure Interface Controls System Overview 120VAC Motors M12 Connectors B W G 110 120V Line B W G 110 120V Line RS485 120VAC Motor RS485 120VAC Motor stem Overview 120VAC Motors Data Cable Pin Out RJ45 Connector 1 ORANGE WHITE 2 ORANGE 3 GREE...

Page 10: ...mm 7 197mm 5 127mm 6 167mm 1 46mm 3 81mm 3 76mm 22mm 1 27mm 1 32mm 3 79mm Endcap Fascia Dimensions Dual Roller Pocket Headbox Dimensions Dual Roller Surface Headbox Dimensions OVERALL WIDTH HEM BAR SHADE HEIGHT Fabric Width Overall Width Dim A When measuring shade height remember to include Endcaps Fascia 1 43mm 7 178mm 7 178mm 3 76mm 1 17mm 1 17mm 3 76mm SHADE FABRIC FASCIA 1 76mm 4 121mm 1 46mm ...

Reviews: