Plugging TV into Controller for Power

  TV can be plugged into outlet on Controller to power the TV. The outlet is 
fused to protect the TV from power surges. The outlet provides power only when 
the lift is fully up, and cuts power as soon as it starts going down.

CC/12VT Port

 

The Second RJ11 terminal from the left, marked CC/12VT, is a combined 

Contact Closure and 12 Volt Trigger port.

 

Contact Closure uses pins 1,2,3,4 and works as follows:

Pin 4      GND (COM)
Pin 3      Up (closing pin 4 and 3 will make the lift go up)
Pin 2      Down (closing pin 4 and 2 will make the lift go down)
Pin 1      Stop (closing pin 1 and 4 will stop the lift)

 

Contact Closure can be set up as a two- or three-button system if preferred.  

In a two-button system, Pin 1 is not used. The lift will stop if either the up or 
down buttons are pressed while the lift is in motion. Contact closure also works 
as either a momentary or permanent closure.

12 Volt trigger uses pins 5 and 6 and works as follows:

Pin 5      DC 12V(+)
Pin 6      DC 12V(-)

The presence of voltage on pins 5 and 6 causes the lift to go up.
No voltage on pins 5 and 6 causes the lift to go down.
The range of acceptable DC voltage is 8V to 18V. 

Sensor Port (For Future Use)

  The RJ11 terminal on the right, marked EMERG. sensor port, is an extra 
sensor port. If desired, this terminal may be used with an additional external safety 
switch or sensor. Using an NC switch to close Pins 2 and 4 will disable the lift.  
When the contacts are opened, the lift will operate again. Pin 3 in this terminal 
may be used to supply 12VDC power to the external sensor if required.

 

FCC Device:  This device complies with Part 15 of the FCC Rules.  Operation 

is subject to the following conditions: (1) this device may not cause harmful 
interference, and (2) this device must accept any interference received including 
interference that may cause undesired operation.

Used for

IR Control

Flatscreen Lift by Draper, Inc.

 

page 6 of 7

Interfacing Instructions

RS-232C 9-pin connector:

Hardware Overview

     3 wire RS-232C protocol:
     9600 baud / 8data bits / 1 stop bits / no parity / no fl ow control

DB9 female D type connector:

     Pin 2 (TX) - transmit
     Pin 3 (RX) - receive
     Pin 5 (GND) - signal ground

Commands: (ASCII Code)

    :UP000  - upward movement command
    :Dn000  - downward movement command

CC/Trig. port

1-CC stop, 2-CC dn

3-CC up, 4-GND

5-Trig. -in 12V(+)

6-Trig. -in 12V(-)

1..................6

LIFT

Emerg.

sensor port

2-in, 3- +12V

4-GND

1..................4

WARNING!

RISK OF ELECTRICAL SHOCK

DISCONNECT FROM POWER BEFORE SERVICING

Used for 

IRS-232 

Control

5

4

3

2

1

9

8

7

6

GND

RX

TX

CE Adapter Plug
plugs in to back of 
220V controller

Summary of Contents for Flatscreen Lift FSL-F-42

Page 1: ...stall near any heat sources including radiators heat registers stoves or other equipment including amplifiers that produces heat Do not install without proper use of the polarized or grounding plug A polarized plug has two blades with one wider than the other A grounding plug has two blades and a third grounding prong The wide blade or the third prong is pro vided for your safety If the provided p...

Page 2: ... inside front and sides of the cabinet Caution Prior to installing ensure the furniture cabinetry being used is large enough and strong enough to hold the FlastScreen Lift and the display without tipping see diagram on next page for minimum height requirements If attaching to wall installer is responsible for ensuring appropriate hardware is used and wall and studs are strong enough to hold the co...

Page 3: ...and nut with lift bracket Tighten each screw with an open ended socket wrench by turning clockwise until tight Display bracket installation To ensure optimal installation this kit includes various screws of different diameters and lengths Place your TV screen down on a soft flat surface and locate the threaded mounting points that are located on the back of the display Determine which screw is the...

Page 4: ...p and down buttons have been pushed before the controller is connected to the lift do the following Enter Setup mode by pressing SETUP and together and holding for 5 seconds Enter the bypass mode refer to bypass instructions below When in bypass mode press and hold until the lift reaches its full down position Once the lift is in the full down position check to see whether the horizontal flashing ...

Page 5: ...e taller lift the lift may stop before reaching the bottom of its travel because the controller is still programmed for the shorter lift and assumes that it has already reached the bottom limit of travel for the shorter lift To use the bypass feature do the following Enter setup mode pressing SETUP and together and holding for 5 seconds Press SETUP until byp appears in the display Use or to move t...

Page 6: ...8V to 18V Sensor Port For Future Use The RJ11 terminal on the right marked EMERG sensor port is an extra sensorport Ifdesired thisterminalmaybeusedwithanadditionalexternalsafety switch or sensor Using an NC switch to close Pins 2 and 4 will disable the lift When the contacts are opened the lift will operate again Pin 3 in this terminal may be used to supply 12VDC power to the external sensor if re...

Page 7: ...upward movement Press SETUP button until Iru shows up on the display Press button A single beep indicates that system is ready for program ming Aim your infrared remote control at the infrared eye which should be con nected to the infrared port on the bottom of your controller Press the remote control button you would like to designate for upward movement You will hear a double beep first and then...