Controller Programming Instructions 

IMPORTANT: 

  THE LIFT MUST BE WORKING AGAINST A MINIMUM LOAD OF AT 

 

LEAST 15 LBS IN ORDER TO FUNCTION PROPERLY. This can be 

 

achieved by either (1) attaching weight to the mounting brackets, or (2) 

 

manually by applying hand pressure at the top of both slides during 

 operation.

  PLEASE READ THROUGH THESE INSTRUCTIONS CAREFULLY 

 

BEFORE ATTEMPTING TO OPERATE THE CONTROLLER OR THE LIFT.  

 

IT WILL SAVE YOU MUCH TIME AND EFFORT.

Programming the Controller

 

The controller is pre-programmed and tested at the factory, and should operate 

properly immediately upon installation. However, there are several functions 
that can be programmed to your specifi c requirements. Please note that when 
power is fi rst applied to the controller, a horizontal fl ashing bar may appear in 
the display. If the fl ashing bar is in the upper right-hand corner (Fig 1), it means 
that the system thinks the lift is in the fully extended or “up” position.

                                        Fig. 1                             Fig. 2
  If the fl ashing bar is in the lower left-hand corner (Fig. 2), it means that the 
system thinks the lift is in the fully closed or “down” position. In either case, 
compare the actual position of the lift with the indication on the display before 
proceeding with programming. If they are not the same, follow the instructions 
for “Extension Programming” before programming other functions.

Entering Setup Mode

 

Before any of the functions of the controller can be programmed, you must 

fi rst enter the Setup mode. To enter the Setup mode, do the following:

  Press SETUP and   together, and hold for 5 seconds. EP should appear 

 

on the controller display. The controller is now unlocked and you may now 

 

access and program all the controller functions.

  By repeatedly pressing SETUP, you may toggle through the functions, 

 

which are abbreviated and will appear in the display in the following order:

 

 

Function Display

 

 

Extension Programming   

EP

 

 

Add remote control   

A.rc

 

 

Clear remote control   

C.rc

 

 

Current down   

Cu.d

 

 

Current Up   

Cu.U

 

 

Infrared down   

Ird

 

 

Infrared up   

Iru

 

 

Count   

Cou

 

 

bypass   

byp

 

 

End   

End

  To exit setup mode:

  Press SETUP until End appears in the display, then press  . A brief 
  description and procedure for programming each of the functions follows.

Extension Programming

   

Used to program the lift to stop at any desired extension height.

   

NOTE: WHEN ATTEMPTING TO PROGRAM EXTENSION HEIGHT, IT 

IS VERY IMPORTANT TO START WITH THE LIFT IN THE FULLY CLOSED OR 
“DOWN” POSITION. If you see that the horizontal bar is fl ashing in the lower left 
corner of the display, but the lift is not in the lowest or “closed”  position, (which 
often happens when the “up” and “down” buttons have been pushed before the 
controller is connected to the lift), do the following:

  Enter Setup mode by pressing SETUP and   together, and holding for 5 

 seconds.

  Enter the bypass mode (refer to bypass instructions below).

  When in bypass mode, press and hold   until the lift reaches its full down 

 position.

  Once the lift is in the full down position, check to see whether the 

  horizontal fl ashing bar is in the lower left-hand corner of the display. If it is 
 not, 

press . The lift position and the controller will now be synchronized 

  and you may proceed with extension programming.

  Press SETUP until EP appears in the display.

  Press  . The extension height can now be programmed.

  Press and hold   until the desired height is reached.

  To lock in the height setting, press SETUP until the display shows the next 

  available function (in this case, A.rc).

  Exit setup mode.

Add Remote Control

  Use to add a second remote control to the controller memory.

  Enter setup mode pressing SETUP and   together, and holding for 5 

 seconds.

  Press SETUP until A.rc appears in the display.

  Press any button on the remote control that is to be added.  Press 

  repeatedly until -.1.r or -.2.r appears in the controller display. The number 
  1 or 2 designates which remote is being added.  If no number shows up 
  after several attempts, clear the memory with the C.rc function (see below) 
  and try again.

Clear Remote Control

  Used to clear all remote control information from the controller memory.

  Enter setup mode pressing SETUP and   together, and holding for 5 

 seconds.

  Press SETUP until C.rc appears in the display.

 Press   and   together, and hold until the display goes blank.

  Proceed to A.rc, or exit setup mode.

Current Down

  Used to set the maximum current limit for downward movement. This is one 
of the safety features of the lift. When the controller senses the current limit you 
have set, it will stop its downward movement, reverse itself, and travel upward 
several inches. (See also the section on “Electrical Current/Load Monitoring” 
below.)

  Enter setup mode pressing SETUP and   together, and holding for 5 

 seconds.

  Press SETUP until Cu.d appears in the display.

 Press   once.  The last programmed current value appears in the display.

 Press   or   to change to the desired value.

  To confi rm and lock in this value, press SETUP until the next available function 

  appears, (in this case Cu.U).

  Exit setup mode.

Current Up

 

Used to set the maximum current limit for upward movement.  (See also 

the section on “Electrical Current/Load Monitoring” below.)

  Enter setup mode pressing SETUP and   together, and holding for 5 

 seconds.

  Press SETUP until Cu.U appears in the display.

 Press   once. The last programmed current value appears in the display.

 Press   or   to change to the desired value.

  To confi rm and lock in this value, press SETUP until the next available 

 

function appears, (in this case Cu.U).

  Exit setup mode.

EP

Arc

Crc

Cu.d

Cu.U

Summary of Contents for Flatscreen Lift FSL-F-42

Page 1: ...stall near any heat sources including radiators heat registers stoves or other equipment including amplifiers that produces heat Do not install without proper use of the polarized or grounding plug A polarized plug has two blades with one wider than the other A grounding plug has two blades and a third grounding prong The wide blade or the third prong is pro vided for your safety If the provided p...

Page 2: ... inside front and sides of the cabinet Caution Prior to installing ensure the furniture cabinetry being used is large enough and strong enough to hold the FlastScreen Lift and the display without tipping see diagram on next page for minimum height requirements If attaching to wall installer is responsible for ensuring appropriate hardware is used and wall and studs are strong enough to hold the co...

Page 3: ...and nut with lift bracket Tighten each screw with an open ended socket wrench by turning clockwise until tight Display bracket installation To ensure optimal installation this kit includes various screws of different diameters and lengths Place your TV screen down on a soft flat surface and locate the threaded mounting points that are located on the back of the display Determine which screw is the...

Page 4: ...p and down buttons have been pushed before the controller is connected to the lift do the following Enter Setup mode by pressing SETUP and together and holding for 5 seconds Enter the bypass mode refer to bypass instructions below When in bypass mode press and hold until the lift reaches its full down position Once the lift is in the full down position check to see whether the horizontal flashing ...

Page 5: ...e taller lift the lift may stop before reaching the bottom of its travel because the controller is still programmed for the shorter lift and assumes that it has already reached the bottom limit of travel for the shorter lift To use the bypass feature do the following Enter setup mode pressing SETUP and together and holding for 5 seconds Press SETUP until byp appears in the display Use or to move t...

Page 6: ...8V to 18V Sensor Port For Future Use The RJ11 terminal on the right marked EMERG sensor port is an extra sensorport Ifdesired thisterminalmaybeusedwithanadditionalexternalsafety switch or sensor Using an NC switch to close Pins 2 and 4 will disable the lift When the contacts are opened the lift will operate again Pin 3 in this terminal may be used to supply 12VDC power to the external sensor if re...

Page 7: ...upward movement Press SETUP button until Iru shows up on the display Press button A single beep indicates that system is ready for program ming Aim your infrared remote control at the infrared eye which should be con nected to the infrared port on the bottom of your controller Press the remote control button you would like to designate for upward movement You will hear a double beep first and then...