background image

Copyright © 2008 Draper Inc. 

Form FSL_Inst08-R 

Print ed in U.S.A.

Installation/Operating Instructions

Flatscreen Lift by Draper

If you encounter any diffi culties installing or servicing your FSL Flatscreen Lift, call your 
dealer or Draper, Inc. in Spiceland, In di ana, 765-987-7999, or fax 765-987-7142.

®

  Please unpack your shipment and verify that you have received all of the 
parts listed below. Lift and components ship in two cartons. 

•  One (1) U-channel mounting bar (packed in separate carton)
•  One (1) FSL Lift
•  One (1) Control Box
•  One (1) RF Remote Control
•  One (1) Control Cable Wiring (attaches controller to lift) 
•  One (1) Power Cord
•  One (1) Universal TV Mount
•  One (1) Set 8 bolts and nuts 
•  One (1) Secondary Shelf
•  Two (2) Secondary Shelf Stop Brackets
•  One (1) Set of Lift Mounting Directions/Controller Programming Instructions

  You will need the following tools to install the lift: 

•  One #2½ metric Allen wrench 
•  One #4 metric Allen wrench 
•  One #5 metric Allen wrench 
•  One drill with a #2 Phillips head screw tip 
•  One #5 Vix bit

Caution

  Read instructions completely before proceeding.

  Follow instructions carefully. Installation contrary to instructions invalidates 

 warranty.

  The Flatscreen Lift must be installed on a ¾" thick back panel, such as 

 

plywood, MDF or other stable material.

  Do not obstruct operation of lift with fi ngers or any object. Serious injury or 

 

damage could result.

  Installer must provide adequate structure, and must also secure furniture to 

 

wall to prevent tipping.

Note:

 

Unit has been thoroughly inspected and tested at factory and found to be 

operating properly prior to shipment.

Lift 

Control Box 

Hardware

RF

Remote

Secondary Shelf

Secondary Shelf

Stop Brackets

Controller Cable 

U-Shaped

Mounting Bar

Universal TV

Mount and Hardware

Important Safety Instructions 

  The lift requires a minimum load of 15 lbs in order to function properly. This can 

 

be achieved by either (1) attaching weight to the mounting brackets, or (2) 

 

manually applying hand pressure at the top of both slides during operation.

Caution:  If manally applying pressure to the top of both slides, keep 

hands, clothing and other objects out of the operational area of the lift. 

  The lift controller has an intermittant two cycle operation—one cycle to its 

 

upper position and one cycle to its lowered position. The controller cycles 

 

should always start in the lowered position. The cycle time is 50 seconds on, 

 

150 seconds off.

  The Maximum environment temperature of controller is not to exceed 104° F 

 (40° 

C).

  Do not use this apparatus near water or moisture—for example, in a wet 

 

basement, near a swimming pool, etc.

  Clean only with dry cloth.

  Do not block any ventilation openings. Install in accordance with the manufac-

 turer’s 

instructions.

  Do not install near any heat sources, including radiators, heat registers, stoves, 

 

or other equipment (including amplifi ers) that produces heat.

  Do not install without proper use of the polarized or grounding plug. A polarized 

 

plug has two blades with one wider than the other. A grounding plug has two 

 

blades and a third grounding prong. The wide blade or the third prong is pro-

 

vided for your safety. If the provided plug does not fi t into your outlet, consult an 

 electrician.

  Protect the power cord from being stepped on or pinched, particularly at the 

 

plugs, convenience receptacles and the point where the cord exits from the 

 apparatus.

  Only use attachments/accessories specifi ed by the manufacturer.

11

  Use only with the cart, stand, tripod, bracket or table specifi ed by the manu-

  facturer, or sold with the apparatus. When a cart or rack is used, use caution 
  when moving the cart/apparatus combination to avoid injury from tip-over.

12

  Unplug the apparatus during lightning storms or when unused for long periods 

 of 

time.

13

 Refer all servicing to qualifi ed personnel. Servicing is required when the ap-

  paratus has been damaged in any way, including but not limited to: power 
  supply cord or plug cut, frayed or otherwise damaged; liquid spilled/objects 
  fallen into the unit; exposure to rain or moisture; unit not operating normally; or 
  unit has been dropped.

14

 

WARNING:

 The main plug/appliance coupler/direct plug-in adapter is used as a

  disconnect device. The disconnect device MUST remain readily available within 
 easy 

reach.

15

  This lightning fl ash with arrowhead symbol within an equilateral triangle is 

  intended to alert the user to the presence of non-insulated “dangerous voltage” 
  within the product’s enclosure that may be of suffi cient magnitude to constitute 
  a risk of electric shock. Where in a manufacturer’s service documentation, for 
  example in circuit diagrams or lists of components, a symbol “ ” is used to 
  indicate that a specifi c component shall be replaced only by the component 
  specifi ed in that documentation for safety reasons.

16

  When apparatus operation and installation instructions contain instructions for 

  use by service personnel, such instructions shall be separate in format from 
  other instructions and preceded by the word “CAUTION” and the following 
  or the equivalent. “These servicing instructions are for use by qualifi ed service 
  personnel only. To reduce the risk of electric shock do not perform any servic-
  ing other than that contained in the operating instructions unless you are quali-
  fi ed to do so.”

17

  A warning that an apparatus with class I construction shall be connected to a 

  mains socket outlet with a protective earthing connection.

18

  The unit shall not be exposed to dripping or splashing and no objects fi lled with 

  liquids, such as vases, shall be placed on the unit.

WARNING/AVERTISSEMENT

RISK OF ELECTRIC SHOCK. DO NOT OPEN

RISQUE DE CHOC ELECTRICUE. NE PAS OUVRIR.

Summary of Contents for Flatscreen Lift FSL-F-42

Page 1: ...stall near any heat sources including radiators heat registers stoves or other equipment including amplifiers that produces heat Do not install without proper use of the polarized or grounding plug A polarized plug has two blades with one wider than the other A grounding plug has two blades and a third grounding prong The wide blade or the third prong is pro vided for your safety If the provided p...

Page 2: ... inside front and sides of the cabinet Caution Prior to installing ensure the furniture cabinetry being used is large enough and strong enough to hold the FlastScreen Lift and the display without tipping see diagram on next page for minimum height requirements If attaching to wall installer is responsible for ensuring appropriate hardware is used and wall and studs are strong enough to hold the co...

Page 3: ...and nut with lift bracket Tighten each screw with an open ended socket wrench by turning clockwise until tight Display bracket installation To ensure optimal installation this kit includes various screws of different diameters and lengths Place your TV screen down on a soft flat surface and locate the threaded mounting points that are located on the back of the display Determine which screw is the...

Page 4: ...p and down buttons have been pushed before the controller is connected to the lift do the following Enter Setup mode by pressing SETUP and together and holding for 5 seconds Enter the bypass mode refer to bypass instructions below When in bypass mode press and hold until the lift reaches its full down position Once the lift is in the full down position check to see whether the horizontal flashing ...

Page 5: ...e taller lift the lift may stop before reaching the bottom of its travel because the controller is still programmed for the shorter lift and assumes that it has already reached the bottom limit of travel for the shorter lift To use the bypass feature do the following Enter setup mode pressing SETUP and together and holding for 5 seconds Press SETUP until byp appears in the display Use or to move t...

Page 6: ...8V to 18V Sensor Port For Future Use The RJ11 terminal on the right marked EMERG sensor port is an extra sensorport Ifdesired thisterminalmaybeusedwithanadditionalexternalsafety switch or sensor Using an NC switch to close Pins 2 and 4 will disable the lift When the contacts are opened the lift will operate again Pin 3 in this terminal may be used to supply 12VDC power to the external sensor if re...

Page 7: ...upward movement Press SETUP button until Iru shows up on the display Press button A single beep indicates that system is ready for program ming Aim your infrared remote control at the infrared eye which should be con nected to the infrared port on the bottom of your controller Press the remote control button you would like to designate for upward movement You will hear a double beep first and then...

Reviews: