background image

Section 9 -

 Adjustments

 CAUTION:

 Be sure all switches are in "off" position before adjusting limit 

switches Always be prepared to shut lift off manually when new adjustment 

is being tested.

Limit switches for the AeroLift are preset at the factory. The "Up" 

(closed)

 limit 

switch is set for fully closed. The "down" 

(show)

 limit switch is set for fully lowered. 

Once unit is in place, the "down" limit switch may need to be changed to stop 

the AeroLift closer to the ceiling 

(that is, to raise the "down" position)

. Limit switches 

are located on the end of roller, and are accessible by removing the cover of the 

junction box at the left end of the unit. To adjust the limit switches, use a 

5/32

(4mm)

screwdriver/hex key.

 CAUTION:

  It is not uncommon to overheat the motor during initial 

installation when setting limits. The motor is thermally protected and will 

stop working until it has cooled to a safe temperature before it will start 

operating again. DO NOT physically pull the unit down when this occurs. 

Adjusting "Down" 

(SHOW position)

 — 

"Down" position may be adjusted by 

turning the DOWN limit switch adjustment socket. Turning the socket clockwise 

will stop the AeroLift closer to the ceiling. Turning it counter-clockwise will cause 

the lift to stop at a lower point.

Adjusting "Up" 

(CLOSED position)

 —

 Because the "up" 

("closed")

 position 

is preset at the factory, Draper does not recommend changing this position 

using the limit switch. The "up" position of the closure may be changed by 

changing the length of threaded rod. If necessary, however, "up" position may be 

adjusted by turning the "up" limit switch adjustment socket. Turning the socket 

counterclockwise creates a higher, or more fully closed position. Turning it 

clockwise creates a lower "up" 

(closed)

 position.

 CAUTION:

 Make sure limit switch is set so that AeroLift motor is NOT still 

running after lift is closed. If it continues to cycle once lift is closed, a failure 

may occur, making unit descend rapidly and causing damage and/or injury.

Please Note:

 If load is off-center of pan, it may be necessary to adjust pitch of 

fabric rollers. One set screw is provided on each end of both fabric rollers 

(see 

drawing)

. Use these to adjust roller pitch to keep entire fabric panel taut, so load 

is evenly distributed. Use 

1/8

(3mm)

 hex key to adjust.

JUNCTION BOX

UP LIMIT

DOWN LIMIT

Fabric Roller Adjustment Set Screw

"

(3mm)

 Min. clearance

CAUTION: 

Make

sure there are

no obstructions

to operation.

page 7 of 8

AeroLift 100/150 220V

Summary of Contents for AeroLift 100 220V

Page 1: ... to height of projector optional projector mounting bracket optional ceiling closure and optional Environmental Housing 3 Arrange to provide service access to the unit 4 When installed with Environmental Air Space Housing unit is suitable for use in an environmental air space in accordance with Section 300 22 C of the National Electrical Code and Section 2 128 12 010 3 and 12 100 of the Canadian E...

Page 2: ...uthorized and qualified personnel who have been trained in its safe and effective operation and understand its safety features 21 The safety features of the unit should never be disabled bypassed or overridden The system should not be operated until all safety features are properly and completely installed calibrated and tested 22 Unit may need to comply with local state or district rules and regu...

Page 3: ...e 3 Attach assembly to overhead structure Allow clearance between Environmental Air Space Housing top and structure for ease of future access 4 Install side and end panels and trim frame 8 10 6 7 1 5 6 3 1 6 5 8 9 2 4 2 5 6 5 6 11 13 14 12 Item Qty Part Number Description 1 4 C044 193SA Panel B Environmental Air Space Housing Side 2 4 C044 191SA Panel B Environmental Air Space Housing End 3 2 C044...

Page 4: ... O D x 2mm 8 26 C020 112 Screw 8 32 X 3 8 10mm Type F HWH 9 1 C095 131SA Cover E Environmental Air Space Housing Top 10 1 C028 612 07SA Frame E Trim Ring 11 1 C028 611 01SA Frame E Environmental Air Space Housing Top 12 4 C020 313 Screw 3 8 10mm 16 x 1 25mm GR 5 Zinc Hex Head Cap 13 4 C013 024 Washer 3 8 10mm Flat 14 4 C018 044 NUT 3 8 10mm 16 Zinc Hex Keps 1 Attach Environmental Air Space Housing...

Page 5: ... Draper universal mounts Section 4 Installing Projector If for any reason the hole placement must be changed completely lower AeroLift before attempting to drill holes When attaching projector bracket to plate make sure screws are short enough that they do not touch the motor roller above the plate when lift is closed Unit and projection system should be operated checked and adjusted as necessary ...

Page 6: ...uld be made in accordance with wiring diagram AeroLift 100 150 should be operated and checked prior to installing projector and or optional ceiling closure Section 8 Wiring Diagrams IR Eye Input Low Voltage Trigger 4 28 VDC RS232 485 Inputs Outputs Receiver Button 3 Button Wall Switch DOWN Black COM White UP Red Wall Switch Electrically Straight Data Cable to more LVC IV modules A maximum of six 6...

Page 7: ...clockwise will stop the AeroLift closer to the ceiling Turning it counter clockwise will cause the lift to stop at a lower point Adjusting Up CLOSED position Because the up closed position is preset at the factory Draper does not recommend changing this position using the limit switch The up position of the closure may be changed by changing the length of threaded rod If necessary however up posit...

Page 8: ...it down then re adjust mounting of 5 16 8mm rods in traveling grid to raise panel required distance 9 Test unit operation to confirm that panel will stop in closed position just before touching ceiling CAUTION DO NOT hang from ride or pull down on unit This could create a failure and cause damage and or injury PLEASE NOTE Immediately upon completing surrounding ceiling operate unit to confirm that...

Reviews: