Section 6 -

 Testing Safety Limit Switches

 CAUTION:

 The AeroLift 100 / 150 is equipped with two Safety Limit Switches 

(see "Adjustments")

. This switch may be damaged during shipping or by rough handling 

on the job site. 

1. 

After the AeroLift 100 / 150 has been installed in the ceiling, but before the projector and closure are attached, the Safety Limit must be tested. 

2. 

Use a screwdriver or other tool to hold down the Safety Limit Switch. While holding down Safety Limit Switch, other installer should operate the unit. If the unit 

works, Safety Limit Switch is broken and must be replaced.

 CAUTION:

 Operating the unit without a functioning Safety Limit Switch could cause the unit's motor to continue operating after the lift is closed, leading to a 

failure and the possibility of damage or injury.

Please Note:

 As weight is applied to the AeroLift 100 / 150, the projector plate may shift slightly. If this occurs, use set screws on bottom of fabric roller brackets to 

compensate for shift and level projector plate.

Draper’s optional Universal Projector Mount will hold up to 200 lb 

(90.7kg)

.

See Installation Instructions included with Universal Pojector Mount.
If not using Draper’s Universal Projector Mount, generally the  

video projector should be suspended from the bottom pan  

according to projector manufacturer’s instructions.

Aerolift 100:

  If installing with a closure, maximum projector size is:  

20" x 25" x h. 

(50.8 x 63.5 cm)

 

(width x length x height)

.

Aerolift 150:

  If installing with a closure, maximum projector size is:  

24 

3/4

" x 35" x h. 

(62.9 x 88.9 cm)

 

(width x length x height)

.

The traveling pan is drilled to accept Draper universal mounts.

Section 4 -

 Installing Projector

If for any reason the hole placement must be changed, 

completely lower AeroLift before attempting to drill 

holes. When attaching projector bracket to plate, make 

sure screws are short enough that they do not touch 

the motor/roller above the plate when lift is closed.
Unit and projection system should be operated, 

checked and adjusted as necessary at this time 

(see 

Sec. 9 for limit adjustment procedures)

 CAUTION:

 Keep fingers and other objects away 

from ceiling closure when unit is operating. 

Serious injury or damage can result.

5½”

 

(14cm)

12”

 

(30.5cm)

10”

 

(25.4cm)

12”

 

(30.5cm)

10”

 

(25.4cm)

3½”

 

(8.9cm)

Section 5 -

 Operation

 CAUTION:

 When operating for the first time, cycle unit down and up several times to confirm satisfactory operation. Be prepared to cut POWER if necessary.

•  220V SINGLE STATION CONTROL -

 3-position UP-OFF-DOWN switch permits operation to be stopped at any point. Factory adjusted limit switches 

automatically stop screen when fully down or fully up.

Optional Controls

•  24V CONTROL -

 3-button UP-STOP-DOWN switches stop at any point desired and operate in any sequence. Factory adjusted limit switches automatically stop 

screen when fully up or fully down. Installer should incorporate an all-pole disconnect in fixed wiring available with RF or IR remote.

•  KEY OPERATED SWITCHING -

 Two key-operated switches optionally available with this unit:

• 

Key-operated power supply switch controls power to screen and switches. When “off”, switches will not operate screen.  

Key may be removed from switch in either "on" or "off" position.

• 

Three-position key switch permits the screen to be operated directly by key. Requires screen operator to have a key.

•  RS232 / ETHERNET -

 Serial communication and network communication optionally available.

page 5 of 8

AeroLift 100/150 220V

Summary of Contents for AeroLift 100 220V

Page 1: ... to height of projector optional projector mounting bracket optional ceiling closure and optional Environmental Housing 3 Arrange to provide service access to the unit 4 When installed with Environmental Air Space Housing unit is suitable for use in an environmental air space in accordance with Section 300 22 C of the National Electrical Code and Section 2 128 12 010 3 and 12 100 of the Canadian E...

Page 2: ...uthorized and qualified personnel who have been trained in its safe and effective operation and understand its safety features 21 The safety features of the unit should never be disabled bypassed or overridden The system should not be operated until all safety features are properly and completely installed calibrated and tested 22 Unit may need to comply with local state or district rules and regu...

Page 3: ...e 3 Attach assembly to overhead structure Allow clearance between Environmental Air Space Housing top and structure for ease of future access 4 Install side and end panels and trim frame 8 10 6 7 1 5 6 3 1 6 5 8 9 2 4 2 5 6 5 6 11 13 14 12 Item Qty Part Number Description 1 4 C044 193SA Panel B Environmental Air Space Housing Side 2 4 C044 191SA Panel B Environmental Air Space Housing End 3 2 C044...

Page 4: ... O D x 2mm 8 26 C020 112 Screw 8 32 X 3 8 10mm Type F HWH 9 1 C095 131SA Cover E Environmental Air Space Housing Top 10 1 C028 612 07SA Frame E Trim Ring 11 1 C028 611 01SA Frame E Environmental Air Space Housing Top 12 4 C020 313 Screw 3 8 10mm 16 x 1 25mm GR 5 Zinc Hex Head Cap 13 4 C013 024 Washer 3 8 10mm Flat 14 4 C018 044 NUT 3 8 10mm 16 Zinc Hex Keps 1 Attach Environmental Air Space Housing...

Page 5: ... Draper universal mounts Section 4 Installing Projector If for any reason the hole placement must be changed completely lower AeroLift before attempting to drill holes When attaching projector bracket to plate make sure screws are short enough that they do not touch the motor roller above the plate when lift is closed Unit and projection system should be operated checked and adjusted as necessary ...

Page 6: ...uld be made in accordance with wiring diagram AeroLift 100 150 should be operated and checked prior to installing projector and or optional ceiling closure Section 8 Wiring Diagrams IR Eye Input Low Voltage Trigger 4 28 VDC RS232 485 Inputs Outputs Receiver Button 3 Button Wall Switch DOWN Black COM White UP Red Wall Switch Electrically Straight Data Cable to more LVC IV modules A maximum of six 6...

Page 7: ...clockwise will stop the AeroLift closer to the ceiling Turning it counter clockwise will cause the lift to stop at a lower point Adjusting Up CLOSED position Because the up closed position is preset at the factory Draper does not recommend changing this position using the limit switch The up position of the closure may be changed by changing the length of threaded rod If necessary however up posit...

Page 8: ...it down then re adjust mounting of 5 16 8mm rods in traveling grid to raise panel required distance 9 Test unit operation to confirm that panel will stop in closed position just before touching ceiling CAUTION DO NOT hang from ride or pull down on unit This could create a failure and cause damage and or injury PLEASE NOTE Immediately upon completing surrounding ceiling operate unit to confirm that...

Reviews: