5. HEALTH AND SAFETY INFORMATION
- 8 -
- 17 -
11. TROUBLESHOOTING
7) Use in environments with permanent presence of people.
-
The space heaters can only be used in well-ventilated rooms and when the percentage of
polluting substances in the air does not exceed danger levels for health.
-
A good ventilation is guaranteed when the rooms volume (in m
3
) is at least 30 times the
normal calorific power (in kW) of all machines used in that room. Openings must be also
distributed in height.
-
The concentration of dangerous substances in the air is acceptable until it reaches maximum
levels and the percentage of oxygen in the air exceeds 17% in volume.
-
The apparatus should not be used for continuous heating of stables and farms. Use of a
carbon monoxide detector is recommended.
Warning: Failure to comply with the precautions and instructions provided with this
heater, can result in death, serious bodily injury and property loss or damage from
hazards of fire, explosion, burn, asphyxiation, carbon monoxide poisoning, and/or
electrical shock.
-
Only persons who can understand and follow the instructions should use or service this
heater.
- If you need assistance or heater information such as instructions manual, labels etc. Please
contact Draper Tools.
- Check the heater thoroughly for damage. DO NOT operate a damaged heater.
- DO NOT modify the heater or operate a heater which has been modified from its original
condition.
Warning: We recommend the use of a carbon monoxide detector in the vicinity of the
space heater.
Important: Not for domestic use!. Use in open buildings please abide by the relevant
national and local guidelines and regulations.
-
For indoor use only. Not for use where exposed to weather.
- Use ONLY in well ventilated areas.
Warning: Fire, burn, inhalation and explosion hazard. Keep solid combustibles, such as
building materials, paper or cardboard, a safe distance away from the heater. Never use
the heater in spaces which do or may contain volatile or airborne combustibles, or
products such as gasoline, solvents, paint thinner, dust particles or unknown
chemicals.
Warning: DO NOT use ducting of any sort with this heater.
Trouble
Reason
Remedy
Fan doesn’t
work.
1. No
electricity.
2. Blade stalled by housing/
foreign body.
1. Check power supply.
2. Repair/replace
housing.
Heater will not
ignite.
1. Ignition cable damaged
2. Ignition cable disconnected.
3. Distance between electrode
and burner too large.
1. Only by a qualified person.
2. Only by a qualified person.
3. Adjust distance within 3-8mm.
No gas.
1. Gas cylinder is empty.
2. Gas valve on cylinder
closed.
3. Gas valve of heater not
open.
4. Gas valve iced-up.
1. Replace new gas cylinder.
2. Open the valve.
3. Attempt re-light sequence correctly.
4. Use larger or multi-cylinder supply.
Flame goes out
while heater
running.
1. Thermo-element was not
heated enough.
2. Safety thermo device
activated.
3. Restricted air flow.
1. Repeat ignition process and keep
safety gas valve depressed for a
minimum of 30 seconds, then release
slowly.
2. Allow the heater to cool down for at
least 10 minutes. Check thermo
device and then attempt re-light
sequence correctly.
3. Check heater inlet & outlet, remove
any obstructions.